The use of C2 laminar screws in posterior cervical fusion is a relatively new technique that provides rigid fixation of the axis with minimal risk to the vertebral artery. The techniques of C2 laminar screw placement described in the literature rely solely on anatomical landmarks to guide screw insertion. The authors report on their experience with placement of C2 laminar screws using three-dimensional (3D) fluoroscopy-based image-guidance in eight patients undergoing posterior cervical fusion. Overall, fifteen C2 laminar screws were placed. There were no complications in any of the patients. Average follow-up was 10 months (range 3–14 months). Postoperative computed tomographic (CT) scanning was available for seven patients allowing evaluation of placement of thirteen C2 laminar screws, all of which were in good position with no spinal canal violation. The intraoperative planning function of the image-guided system allowed for 4-mm diameter screws to be placed in all cases. Using modified Odom’s criteria, excellent or good relief of preoperative symptoms was noted in all patients at final follow-up.
Literature
1.
go back to reference Acosta FL Jr, Thompson TL, Campbell S, Weinstein PR, Ames CP (2005) Use of intraoperative isocentric C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement: case report and review of the literature. Spine J 5:339–343PubMedCrossRef Acosta FL Jr, Thompson TL, Campbell S, Weinstein PR, Ames CP (2005) Use of intraoperative isocentric C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement: case report and review of the literature. Spine J 5:339–343PubMedCrossRef
2.
go back to reference Assaker R, Reyns N, Vinchon M, Demondion X, Louis E (2001) Transpedicular screw placement: image-guided versus lateral-view fluoroscopy: in vitro simulation. Spine 26:2160–2164PubMedCrossRef Assaker R, Reyns N, Vinchon M, Demondion X, Louis E (2001) Transpedicular screw placement: image-guided versus lateral-view fluoroscopy: in vitro simulation. Spine 26:2160–2164PubMedCrossRef
3.
go back to reference Austin MS, Vaccaro AR, Brislin B, Nachwalter R, Hilibrand AS, Albert TJ (2002) Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models. Spine 27:2503–2508PubMedCrossRef Austin MS, Vaccaro AR, Brislin B, Nachwalter R, Hilibrand AS, Albert TJ (2002) Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models. Spine 27:2503–2508PubMedCrossRef
4.
go back to reference Bloch O, Holly LT, Park J, Obasi C, Kim K, Johnson JP (2001) Effect of frameless stereotaxy on the accuracy of C1–2 transarticular screw placement. J Neurosurg 95:74–79PubMed Bloch O, Holly LT, Park J, Obasi C, Kim K, Johnson JP (2001) Effect of frameless stereotaxy on the accuracy of C1–2 transarticular screw placement. J Neurosurg 95:74–79PubMed
5.
go back to reference Bolger C, Wigfield C (2000) Image-guided surgery: applications to the cervical and thoracic spine and a review of the first 120 procedures. J Neurosurg 92:175–180PubMed Bolger C, Wigfield C (2000) Image-guided surgery: applications to the cervical and thoracic spine and a review of the first 120 procedures. J Neurosurg 92:175–180PubMed
6.
go back to reference Gorek J, Acaroglu E, Berven S, Yousef A, Puttlitz CM (2005) Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation. Spine 30:1513–1518PubMedCrossRef Gorek J, Acaroglu E, Berven S, Yousef A, Puttlitz CM (2005) Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation. Spine 30:1513–1518PubMedCrossRef
7.
go back to reference Holly LT, Foley KT (2006) Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy. Spine 31:536–540, discussion 541PubMedCrossRef Holly LT, Foley KT (2006) Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy. Spine 31:536–540, discussion 541PubMedCrossRef
8.
go back to reference Holly LT, Foley KT (2003) Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placement. Technical note. J Neurosurg 99:324–329PubMed Holly LT, Foley KT (2003) Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placement. Technical note. J Neurosurg 99:324–329PubMed
9.
go back to reference Hott JS, Deshmukh VR, Klopfenstein JD, Sonntag VK, Dickman CA, Spetzler RF (2004) Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurgery 54:1131–1136, discussion 1136–1137PubMedCrossRef Hott JS, Deshmukh VR, Klopfenstein JD, Sonntag VK, Dickman CA, Spetzler RF (2004) Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurgery 54:1131–1136, discussion 1136–1137PubMedCrossRef
10.
go back to reference Hott JS, Papadopoulos SM, Theodore N, Dickman CA, Sonntag VK (2004) Intraoperative Iso-C C-arm navigation in cervical spinal surgery: review of the first 52 cases. Spine 29:2856–2860PubMedCrossRef Hott JS, Papadopoulos SM, Theodore N, Dickman CA, Sonntag VK (2004) Intraoperative Iso-C C-arm navigation in cervical spinal surgery: review of the first 52 cases. Spine 29:2856–2860PubMedCrossRef
11.
go back to reference Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (2000) Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord 13:218–224PubMedCrossRef Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (2000) Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord 13:218–224PubMedCrossRef
12.
go back to reference Kothe R, Matthias Strauss J, Deuretzbacher G, Hemmi T, Lorenzen M, Wiesner L (2001) Computer navigation of parapedicular screw fixation in the thoracic spine: a cadaver study. Spine 26:E496–501PubMedCrossRef Kothe R, Matthias Strauss J, Deuretzbacher G, Hemmi T, Lorenzen M, Wiesner L (2001) Computer navigation of parapedicular screw fixation in the thoracic spine: a cadaver study. Spine 26:E496–501PubMedCrossRef
13.
go back to reference Lapsiwala SB, Anderson PA, Oza A, Resnick DK (2006) Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 58:516–521, discussion 516–521PubMed Lapsiwala SB, Anderson PA, Oza A, Resnick DK (2006) Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 58:516–521, discussion 516–521PubMed
14.
go back to reference Leonard JR, Wright NM (2006) Pediatric atlantoaxial fixation with bilateral, crossing C-2 translaminar screws. Technical note. J Neurosurg 104:59–63PubMed Leonard JR, Wright NM (2006) Pediatric atlantoaxial fixation with bilateral, crossing C-2 translaminar screws. Technical note. J Neurosurg 104:59–63PubMed
15.
go back to reference Merloz P, Tonetti J, Pittet L, Coulomb M, Lavallee S, Sautot P (1998) Pedicle screw placement using image guided techniques. Clin Orthop Relat Res 354: 39–48PubMedCrossRef Merloz P, Tonetti J, Pittet L, Coulomb M, Lavallee S, Sautot P (1998) Pedicle screw placement using image guided techniques. Clin Orthop Relat Res 354: 39–48PubMedCrossRef
16.
go back to reference Mizuno J, Nakagawa H, Watabe T (2001) Combined anterior and posterior instrumentation in severe fracture-dislocation of the lower cervical spine with help of navigation: a case report. J Clin Neurosci 8:446–450PubMedCrossRef Mizuno J, Nakagawa H, Watabe T (2001) Combined anterior and posterior instrumentation in severe fracture-dislocation of the lower cervical spine with help of navigation: a case report. J Clin Neurosci 8:446–450PubMedCrossRef
17.
go back to reference Nolte L, Zamorano L, Arm E, Visarius H, Jiang Z, Berlerman U et al (1996) Image-guided computer-assisted spine surgery: a pilot study on pedicle screw fixation. Stereotact Funct Neurosurg 66:108–117PubMedCrossRef Nolte L, Zamorano L, Arm E, Visarius H, Jiang Z, Berlerman U et al (1996) Image-guided computer-assisted spine surgery: a pilot study on pedicle screw fixation. Stereotact Funct Neurosurg 66:108–117PubMedCrossRef
18.
go back to reference Villavicencio AT, Burneikiene S, Bulsara KR, Thramann JJ (2005) Utility of computerized isocentric fluoroscopy for minimally invasive spinal surgical techniques. J Spinal Disord Tech 18:369–375PubMedCrossRef Villavicencio AT, Burneikiene S, Bulsara KR, Thramann JJ (2005) Utility of computerized isocentric fluoroscopy for minimally invasive spinal surgical techniques. J Spinal Disord Tech 18:369–375PubMedCrossRef
19.
go back to reference Wang MY (2006) C2 crossing laminar screws: cadaveric morphometric analysis. Neurosurgery 59:ONS84–88, discussion ONS84–88PubMedCrossRef Wang MY (2006) C2 crossing laminar screws: cadaveric morphometric analysis. Neurosurgery 59:ONS84–88, discussion ONS84–88PubMedCrossRef
20.
go back to reference Wigfield C, Bolger C (2001) A technique for frameless stereotaxy and placement of transarticular screws for atlanto-axial instability in rheumatoid arthritis. Eur Spine J 10:264–268 (see comment)PubMedCrossRef Wigfield C, Bolger C (2001) A technique for frameless stereotaxy and placement of transarticular screws for atlanto-axial instability in rheumatoid arthritis. Eur Spine J 10:264–268 (see comment)PubMedCrossRef
21.
go back to reference Wright NM (2004) Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 17:158–162PubMed Wright NM (2004) Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 17:158–162PubMed
22.
go back to reference Wright NM (2005) Translaminar rigid screw fixation of the axis. Technical note. J Neurosurg Spine 3:409–414PubMedCrossRef Wright NM (2005) Translaminar rigid screw fixation of the axis. Technical note. J Neurosurg Spine 3:409–414PubMedCrossRef
23.
go back to reference Youkilis AS, Quint DJ, McGillicuddy JE, Papadopoulos SM (2001) Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery 48:771–778, discussion 778–779PubMedCrossRef Youkilis AS, Quint DJ, McGillicuddy JE, Papadopoulos SM (2001) Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery 48:771–778, discussion 778–779PubMedCrossRef
Metadata
Title
Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance
Authors
Eric W. Nottmeier
Andrew B. Foy
Publication date
01-04-2008
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 4/2008
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-007-0557-x

Other articles of this Issue 4/2008

European Spine Journal 4/2008 Go to the issue