Skip to main content
Top
Published in: European Spine Journal 1/2008

01-01-2008 | Original Article

Consequences of patient position in the radiographic measurement of artificial disc replacement angles

Authors: Victor Kosmopoulos, John McManus, Constantin Schizas

Published in: European Spine Journal | Issue 1/2008

Login to get access

Abstract

Accurate clinical measurement of spinal range of motion (ROM) is essential in the evaluation of artificial disc performance. The effect of patient placement with respect to the X-ray beam source is yet to be reported and may be an influencing factor in radiographic artificial disc angle measurements. This study aims to evaluate how radiographic patient placement influences artificial disc angle measurements. An anatomically accurate synthetic L4–L5 motion segment was instrumented with an artificial disc and two pins. The instrumented motion segment was mounted onto a frame allowing for independent rotation and elevation while holding the artificial disc angle and anatomical position between L4 and L5 fixed. Analyses included descriptive statistics, evaluation of uncertainty, intra- and inter-observer, and a 2-way analysis of variance (ANOVA). The mean angle measurement range at the various positions was 1.26° for the pin, and 2.74° for the artificial disc endplates. The centered patient position had the highest inter- and intra-observer reliability. ANOVA results showed elevation effects to be statistically significant (P = 0.021), and rotational effects to be extremely statistically significant (P < 0.0001) for the pin angles. In terms of the mean artificial disc angle, however, the ANOVA showed a highly statistically significant interaction term (P = 0.002). A significant difference was found in the angle measurements of a fixed artificial disc prosthesis based on a sample of patient radiographic placement positions. Since it is important to assess the success of an artificial disc replacement by evaluating the relatively small ROM present, it is crucial to aim at minimizing the error by placing the patient parallel to the plate with the beam centered not at the mid lumbar spine, but at the level of the arthroplasty, for both flexion and extension views.
Literature
1.
go back to reference Cakir B, Richter M, Puhl W, Schmidt R (2006) Reliability of motion measurements after total disc replacement: the spike and the fin method. Eur Spine J 15:165–173PubMedCrossRef Cakir B, Richter M, Puhl W, Schmidt R (2006) Reliability of motion measurements after total disc replacement: the spike and the fin method. Eur Spine J 15:165–173PubMedCrossRef
2.
go back to reference Cunningham BW, Gordon JD, Dmitriev AE, Hu N, McAfee PC (2003) Biomechanical evaluation of total disc replacement arthroplasty: an in vitro human cadaveric model. Spine 28:S110–S117PubMedCrossRef Cunningham BW, Gordon JD, Dmitriev AE, Hu N, McAfee PC (2003) Biomechanical evaluation of total disc replacement arthroplasty: an in vitro human cadaveric model. Spine 28:S110–S117PubMedCrossRef
3.
go back to reference Huang RC, Girardi FP, Cammisa FP Jr, Tropiano P, Marnay T (2003) Long-term flexion–extension range of motion of the prodisc total disc replacement. J Spinal Disord Tech 16:435–440PubMedCrossRef Huang RC, Girardi FP, Cammisa FP Jr, Tropiano P, Marnay T (2003) Long-term flexion–extension range of motion of the prodisc total disc replacement. J Spinal Disord Tech 16:435–440PubMedCrossRef
4.
go back to reference Huang RC, Girardi FP, Cammisa FP Jr, Lim MR, Tropiano P, Marnay T (2005) Correlation between range of motion and outcome after lumbar total disc replacement: 8.6-year follow-up. Spine 30:1407–1411PubMedCrossRef Huang RC, Girardi FP, Cammisa FP Jr, Lim MR, Tropiano P, Marnay T (2005) Correlation between range of motion and outcome after lumbar total disc replacement: 8.6-year follow-up. Spine 30:1407–1411PubMedCrossRef
5.
go back to reference Huang RC, Tropiano P, Marnay T, Girardi FP, Lim MR, Cammisa FP Jr (2006) Range of motion and adjacent level degeneration after lumbar total disc replacement. Spine J 6:242–247PubMedCrossRef Huang RC, Tropiano P, Marnay T, Girardi FP, Lim MR, Cammisa FP Jr (2006) Range of motion and adjacent level degeneration after lumbar total disc replacement. Spine J 6:242–247PubMedCrossRef
6.
go back to reference Kuklo TR, Polly DW, Owens BD, Zeidman SM, Chang AS, Klemme WR (2001) Measurement of thoracic and lumbar fracture kyphosis: evaluation of intraobserver, interobserver, and technique variability. Spine 26:61–65PubMedCrossRef Kuklo TR, Polly DW, Owens BD, Zeidman SM, Chang AS, Klemme WR (2001) Measurement of thoracic and lumbar fracture kyphosis: evaluation of intraobserver, interobserver, and technique variability. Spine 26:61–65PubMedCrossRef
7.
go back to reference Lemaire JP, Carrier H, SariAli e, Skalli W, Lavaste F (2005) Clinical and radiological outcomes with the Charite artificial disc: a 10-year minimum follow-up. [erratum appears in J Spinal Disord Tech. 2006 Feb;19(1):76 Note: Sari Ali, El-Hadi [corrected to Sariali, El-hadi]]. J Spinal Disord Tech 18:353–359 Lemaire JP, Carrier H, SariAli e, Skalli W, Lavaste F (2005) Clinical and radiological outcomes with the Charite artificial disc: a 10-year minimum follow-up. [erratum appears in J Spinal Disord Tech. 2006 Feb;19(1):76 Note: Sari Ali, El-Hadi [corrected to Sariali, El-hadi]]. J Spinal Disord Tech 18:353–359
8.
go back to reference Lim MR, Girardi FP, Zhang K, Huang RC, Peterson MG, Cammisa FP Jr (2005) Measurement of total disc replacement radiographic range of motion: a comparison of two techniques. J Spinal Disord Tech 18:252–256PubMed Lim MR, Girardi FP, Zhang K, Huang RC, Peterson MG, Cammisa FP Jr (2005) Measurement of total disc replacement radiographic range of motion: a comparison of two techniques. J Spinal Disord Tech 18:252–256PubMed
9.
go back to reference Lim MR, Loder RT, Huang RC, Lyman S, Zhang K, Sama A, Papadopoulos EC, Warner K, Girardi FP, Cammisa FP Jr (2006) Measurement error of lumbar total disc replacement range of motion. Spine 31:E291–E297PubMedCrossRef Lim MR, Loder RT, Huang RC, Lyman S, Zhang K, Sama A, Papadopoulos EC, Warner K, Girardi FP, Cammisa FP Jr (2006) Measurement error of lumbar total disc replacement range of motion. Spine 31:E291–E297PubMedCrossRef
10.
go back to reference McAfee PC, Cunningham B, Holsapple G, Adams K, Blumenthal S, Guyer RD, Dmietriev A, Maxwell JH, Regan JJ, Isaza J (2005) A prospective, randomized, multicenter Food and Drug Administration investigational device exemption study of lumbar total disc replacement with the CHARITE artificial disc versus lumbar fusion: part II: evaluation of radiographic outcomes and correlation of surgical technique accuracy with clinical outcomes. Spine 30:1576–1583PubMedCrossRef McAfee PC, Cunningham B, Holsapple G, Adams K, Blumenthal S, Guyer RD, Dmietriev A, Maxwell JH, Regan JJ, Isaza J (2005) A prospective, randomized, multicenter Food and Drug Administration investigational device exemption study of lumbar total disc replacement with the CHARITE artificial disc versus lumbar fusion: part II: evaluation of radiographic outcomes and correlation of surgical technique accuracy with clinical outcomes. Spine 30:1576–1583PubMedCrossRef
11.
go back to reference Navidi W (2006) Statistics for engineers and scientists. McGraw-Hill, New York Navidi W (2006) Statistics for engineers and scientists. McGraw-Hill, New York
12.
go back to reference O’Leary P, Nicolakis M, Lorenz MA, Voronov LI, Zindrick MR, Ghanayem A, Havey RM, Carandang G, Sartori M, Gaitanis IN, Fronczak S, Patwardhan AG (2005) Response of Charite total disc replacement under physiologic loads: prosthesis component motion patterns. Spine J 5:590–599PubMedCrossRef O’Leary P, Nicolakis M, Lorenz MA, Voronov LI, Zindrick MR, Ghanayem A, Havey RM, Carandang G, Sartori M, Gaitanis IN, Fronczak S, Patwardhan AG (2005) Response of Charite total disc replacement under physiologic loads: prosthesis component motion patterns. Spine J 5:590–599PubMedCrossRef
13.
go back to reference SariAli E, Lemaire JP, Pascal-Mousselard H, Carrier H, Skalli W (2006) In vivo study of the kinematics in axial rotation of the lumbar spine after total intervertebral disc replacement: long-term results: a 10–14 years follow-up evaluation. Eur Spine J 15:1501–1510CrossRef SariAli E, Lemaire JP, Pascal-Mousselard H, Carrier H, Skalli W (2006) In vivo study of the kinematics in axial rotation of the lumbar spine after total intervertebral disc replacement: long-term results: a 10–14 years follow-up evaluation. Eur Spine J 15:1501–1510CrossRef
14.
go back to reference Seel EH, Verrill CL, Mehta RL, Davies EM (2005) Measurement of fracture kyphosis with the Oxford Cobbometer: intra- and interobserver reliabilities and comparison with other techniques. Spine 30:964–968PubMedCrossRef Seel EH, Verrill CL, Mehta RL, Davies EM (2005) Measurement of fracture kyphosis with the Oxford Cobbometer: intra- and interobserver reliabilities and comparison with other techniques. Spine 30:964–968PubMedCrossRef
15.
go back to reference Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86:420–428CrossRef Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86:420–428CrossRef
16.
go back to reference Wallman KE, Morton AR, Goodman C, Grove R (2005) Reliability of physiological, psychological and cognitive variables in chronic fatigue syndrome and the role of graded exercise. J Sports Sci Med 4:463–471 Wallman KE, Morton AR, Goodman C, Grove R (2005) Reliability of physiological, psychological and cognitive variables in chronic fatigue syndrome and the role of graded exercise. J Sports Sci Med 4:463–471
Metadata
Title
Consequences of patient position in the radiographic measurement of artificial disc replacement angles
Authors
Victor Kosmopoulos
John McManus
Constantin Schizas
Publication date
01-01-2008
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 1/2008
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-007-0486-8

Other articles of this Issue 1/2008

European Spine Journal 1/2008 Go to the issue