Abstract

Currently there are few data available regarding the application and efficacy of computer-assisted procedures in the sacral spine. In order to optimize and standardize this procedure, a controlled experimental investigation has been performed. The aim of the study is to systematically assess the efficacy of a novel three-dimensional image intensifier used for navigated transiliac screw insertion into the first sacral vertebra. Screws were inserted iliosacrally into the first sacral vertebra of preserved human cadaver specimens. The instrument navigated procedure was performed with the “Siremobil Iso-C3D ” (Siemens Medical Solutions) and the “Navigation System” by Stryker. The accuracy and quality of the imaging procedure as well as the fluoroscopic exposure times were measured. These results were compared to three control groups (CT-based navigation, C-arm navigation, and fluoroscopic guidance). In each group a total amount of 20 screws was implanted. Screw position was postoperatively assessed by Iso-C3D or CT-scan. The navigated procedure using the Iso-C3D provided good feasibility characteristics without requiring a specific matching process. It revealed the shortest procedure time of all navigated procedures and significantly decreased fluoroscopic time compared to C-arm navigation and fluoroscopic guidance. Furthermore, Iso-C3D navigation showed no screw malposition and was in this regard superior to C-arm navigated and fluoroscopic guided procedures. The quality of imaging was sufficient for accurate placement, but did not share the high-resolution level of CT-based navigation. These findings indicate that application of the Iso-C3D for navigated transiliac screw insertion into S1 can be recommended as a feasible and safe technique, enabling the surgeon to reduce procedure and fluoroscopic time. Further progress in improving the quality of the Iso-C3D image should be attempted.
Literature
1.
go back to reference Amiot LP, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 25(5):606–614PubMed Amiot LP, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 25(5):606–614PubMed
2.
go back to reference Arand M, Kinzl L, Gebhard F (2002) Sources of error and risks in CT based navigation. Orthopäde 31(4):378–384PubMed Arand M, Kinzl L, Gebhard F (2002) Sources of error and risks in CT based navigation. Orthopäde 31(4):378–384PubMed
3.
go back to reference Arand M, Kinzl L, Gebhard F (2004) Computer-guidance in percutaneous screw stabilization of the iliosacral joint. Clin Orthop 422:201–207PubMed Arand M, Kinzl L, Gebhard F (2004) Computer-guidance in percutaneous screw stabilization of the iliosacral joint. Clin Orthop 422:201–207PubMed
4.
go back to reference Berlemann U, Monin D, Arm E, Nolte LP, Ozdoba C (1997) Planning and insertion of pedicle screws with computer assistance. J Spinal Disord 10(2):117–124PubMed Berlemann U, Monin D, Arm E, Nolte LP, Ozdoba C (1997) Planning and insertion of pedicle screws with computer assistance. J Spinal Disord 10(2):117–124PubMed
5.
go back to reference El Sheik M, Heverhagen JT, Alfke H, Froelich JJ, Hornegger J, Brunner T, Klose KJ, Wagner HJ (2001) Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using a C-arm system: initial results. Radiology 221(3):843–849PubMed El Sheik M, Heverhagen JT, Alfke H, Froelich JJ, Hornegger J, Brunner T, Klose KJ, Wagner HJ (2001) Multiplanar reconstructions and three-dimensional imaging (computed rotational osteography) of complex fractures by using a C-arm system: initial results. Radiology 221(3):843–849PubMed
6.
go back to reference Euler E, Heining S, Riquarts C, Mutschler W (2003) C-arm-based three-dimensional navigation: a preliminary feasibility study. Comput Aided Surg 8(1):35–41PubMed Euler E, Heining S, Riquarts C, Mutschler W (2003) C-arm-based three-dimensional navigation: a preliminary feasibility study. Comput Aided Surg 8(1):35–41PubMed
7.
go back to reference Gebhard F, Weidner A, Liener UC, Stockle U, Arand M (2004) Navigation at the spine. Injury 35(Suppl 1):S35–S45 Gebhard F, Weidner A, Liener UC, Stockle U, Arand M (2004) Navigation at the spine. Injury 35(Suppl 1):S35–S45
8.
go back to reference Giannikas KA, Khan AM, Karski MT, Maxwell HA (2004) Sacroiliac joint fusion for chronic pain: a simple technique avoiding the use of metalwork. Eur Spine J 13(3):253–256PubMed Giannikas KA, Khan AM, Karski MT, Maxwell HA (2004) Sacroiliac joint fusion for chronic pain: a simple technique avoiding the use of metalwork. Eur Spine J 13(3):253–256PubMed
9.
go back to reference Grützner PA, Rose E, Vock B, Holz F, Nolte LP, Wentzensen A (2002) Computer-assisted screw osteosynthesis of the posterior pelvic ring. Initial experiences with an image reconstruction based optoelectronic navigation system. Unfallchirurg 105(3):254–260PubMed Grützner PA, Rose E, Vock B, Holz F, Nolte LP, Wentzensen A (2002) Computer-assisted screw osteosynthesis of the posterior pelvic ring. Initial experiences with an image reconstruction based optoelectronic navigation system. Unfallchirurg 105(3):254–260PubMed
10.
go back to reference Kotsianos D, Rock C, Wirth S, Linsenmaier U, Brandl R, Fischer T, Euler E, Mutschler W, Pfeifer KJ, Reiser M (2002) Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): comparison with plain films and spiral CT. Rofo 174(1):82–87PubMed Kotsianos D, Rock C, Wirth S, Linsenmaier U, Brandl R, Fischer T, Euler E, Mutschler W, Pfeifer KJ, Reiser M (2002) Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): comparison with plain films and spiral CT. Rofo 174(1):82–87PubMed
11.
go back to reference Kotsianos D, Wirth S, Fischer T, Euler E, Rock C, Linsenmaier U, Pfeifer KJ, Reiser M (2004) 3D imaging with an isocentric mobile C-arm. Comparison of image quality with spiral CT. Eur Radiol 14(9):1590–1595PubMed Kotsianos D, Wirth S, Fischer T, Euler E, Rock C, Linsenmaier U, Pfeifer KJ, Reiser M (2004) 3D imaging with an isocentric mobile C-arm. Comparison of image quality with spiral CT. Eur Radiol 14(9):1590–1595PubMed
12.
go back to reference Krivonos O, Gebhard F, Keppler P, Kinzl L, Hesser J, Manner R (2001) Computer assisted treatment of pelvis fractures. Stud Health Technol Inform 81:242–246PubMed Krivonos O, Gebhard F, Keppler P, Kinzl L, Hesser J, Manner R (2001) Computer assisted treatment of pelvis fractures. Stud Health Technol Inform 81:242–246PubMed
13.
go back to reference Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9(3):235–240PubMed Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9(3):235–240PubMed
14.
go back to reference Laine T, Makitalo K, Schlenzka D, Tallroth K, Poussa M, Alho A (1997) Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients. Eur Spine J 6(6):402–405PubMed Laine T, Makitalo K, Schlenzka D, Tallroth K, Poussa M, Alho A (1997) Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients. Eur Spine J 6(6):402–405PubMed
15.
go back to reference Langlotz F, Nolte L (2004) Technical approaches to computer-assisted orthopedic surgery. Eur J Trauma 30(1):1–11 Langlotz F, Nolte L (2004) Technical approaches to computer-assisted orthopedic surgery. Eur J Trauma 30(1):1–11
16.
go back to reference Linsenmaier U, Rock C, Euler E, Wirth S, Brandl R, Kotsianos D, Mutschler W, Pfeifer KJ (2002) Three-dimensional CT with a modified C-arm image intensifier: feasibility. Radiology 224(1):286–292PubMed Linsenmaier U, Rock C, Euler E, Wirth S, Brandl R, Kotsianos D, Mutschler W, Pfeifer KJ (2002) Three-dimensional CT with a modified C-arm image intensifier: feasibility. Radiology 224(1):286–292PubMed
17.
go back to reference Matta JM (1996) Regarding safe and effective placement of ileosacral screws. J Orthop Trauma 10(7):514PubMed Matta JM (1996) Regarding safe and effective placement of ileosacral screws. J Orthop Trauma 10(7):514PubMed
18.
go back to reference Matta JM, Tornetta P III (1996) Internal fixation of unstable pelvic ring injuries. Clin Orthop 329:129–140PubMed Matta JM, Tornetta P III (1996) Internal fixation of unstable pelvic ring injuries. Clin Orthop 329:129–140PubMed
19.
go back to reference Nogler M, Maurer H, Wimmer C, Gegenhuber C, Bach C, Krismer M (2001) Knee pain caused by a fiducial marker in the medial femoral condyle: a clinical and anatomic study of 20 cases. Acta Orthop Scand 72(5):477–480PubMed Nogler M, Maurer H, Wimmer C, Gegenhuber C, Bach C, Krismer M (2001) Knee pain caused by a fiducial marker in the medial femoral condyle: a clinical and anatomic study of 20 cases. Acta Orthop Scand 72(5):477–480PubMed
20.
go back to reference Nolte LP, Beutler T (2004) Basic principles of CAOS. Injury 35(Suppl 1):S6–S16 Nolte LP, Beutler T (2004) Basic principles of CAOS. Injury 35(Suppl 1):S6–S16
21.
go back to reference Nolte LP, Slomczykowski MA, Berlemann U, Strauss MJ, Hofstetter R, Schlenzka D, Laine T, Lund T (2000) A new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation. Eur Spine J 9(sSuppl 1):S78–S88PubMed Nolte LP, Slomczykowski MA, Berlemann U, Strauss MJ, Hofstetter R, Schlenzka D, Laine T, Lund T (2000) A new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation. Eur Spine J 9(sSuppl 1):S78–S88PubMed
22.
go back to reference Nolte LP, Visarius H, Arm E, Langlotz F, Schwarzenbach O, Zamorano L (1995) Computer-aided fixation of spinal implants. J Image Guid Surg 1(2):88–93PubMed Nolte LP, Visarius H, Arm E, Langlotz F, Schwarzenbach O, Zamorano L (1995) Computer-aided fixation of spinal implants. J Image Guid Surg 1(2):88–93PubMed
23.
go back to reference Rock C, Kotsianos D, Linsenmaier U, Fischer T, Brandl R, Vill F, Wirth S, Kaltschmidt R, Euler E, Pfeifer KJ, Reiser M (2002) Studies on image quality, high contrast resolution and dose for the axial skeleton and limbs with a new, dedicated CT system (ISO-C-3 D). Rofo 174(2):170–176PubMed Rock C, Kotsianos D, Linsenmaier U, Fischer T, Brandl R, Vill F, Wirth S, Kaltschmidt R, Euler E, Pfeifer KJ, Reiser M (2002) Studies on image quality, high contrast resolution and dose for the axial skeleton and limbs with a new, dedicated CT system (ISO-C-3 D). Rofo 174(2):170–176PubMed
24.
go back to reference Routt ML Jr, Kregor PJ, Simonian PT, Mayo KA (1995) Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 9(3):207–214PubMed Routt ML Jr, Kregor PJ, Simonian PT, Mayo KA (1995) Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 9(3):207–214PubMed
25.
go back to reference Routt ML Jr, Simonian PT (1996) Internal fixation of pelvic ring disruptions. Injury 27(Suppl 2):B20–B30PubMed Routt ML Jr, Simonian PT (1996) Internal fixation of pelvic ring disruptions. Injury 27(Suppl 2):B20–B30PubMed
26.
go back to reference Schep NW, Haverlag R, van Vugt AB (2004) Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain. J Trauma 57(6):1299–1302PubMed Schep NW, Haverlag R, van Vugt AB (2004) Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain. J Trauma 57(6):1299–1302PubMed
27.
go back to reference Schlenzka D, Laine T, Lund T (2000) Computer-assisted spine surgery. Eur Spine J 9(Suppl 1):S57–S64PubMed Schlenzka D, Laine T, Lund T (2000) Computer-assisted spine surgery. Eur Spine J 9(Suppl 1):S57–S64PubMed
28.
go back to reference Stöckle U, Krettek C, Pohlemann T, Messmer P (2004) Clinical applications—pelvis. Injury 35(Suppl 1):S46–S56 Stöckle U, Krettek C, Pohlemann T, Messmer P (2004) Clinical applications—pelvis. Injury 35(Suppl 1):S46–S56
29.
go back to reference Tile M, Helfet DL, Kellam JF (2003) Fractures of the pelvis and acetabulum. Lippincott Williams and Wilkins, Philadelphia Tile M, Helfet DL, Kellam JF (2003) Fractures of the pelvis and acetabulum. Lippincott Williams and Wilkins, Philadelphia
30.
go back to reference Tonetti J, Carrat L, Blendea S, Merloz P, Troccaz J, Lavallee S, Chirossel JP (2001) Clinical results of percutaneous pelvic surgery. Computer assisted surgery using ultrasound compared to standard fluoroscopy. Comput Aided Surg 6(4):204–211PubMed Tonetti J, Carrat L, Blendea S, Merloz P, Troccaz J, Lavallee S, Chirossel JP (2001) Clinical results of percutaneous pelvic surgery. Computer assisted surgery using ultrasound compared to standard fluoroscopy. Comput Aided Surg 6(4):204–211PubMed
31.
go back to reference Tonetti J, Carrat L, Lavallee S, Pittet L, Merloz P, Chirossel JP (1998) Percutaneous iliosacral screw placement using image guided techniques. Clin Orthop 354:103–110PubMed Tonetti J, Carrat L, Lavallee S, Pittet L, Merloz P, Chirossel JP (1998) Percutaneous iliosacral screw placement using image guided techniques. Clin Orthop 354:103–110PubMed
32.
go back to reference Wendl K, von Recum J, Wentzensen A, Grützner PA (2003) Iso-C3D -gestützte navigierte Implantation von Pedikelschrauben an BWS und LWS. Unfallchirurg 106(11):907–913PubMed Wendl K, von Recum J, Wentzensen A, Grützner PA (2003) Iso-C3D -gestützte navigierte Implantation von Pedikelschrauben an BWS und LWS. Unfallchirurg 106(11):907–913PubMed
33.
go back to reference Winkler D, Vitzthum HE, Seifert V (1999) Spinal markers: a new method for increasing accuracy in spinal navigation. Comput Aided Surg 4(2):101–104PubMed Winkler D, Vitzthum HE, Seifert V (1999) Spinal markers: a new method for increasing accuracy in spinal navigation. Comput Aided Surg 4(2):101–104PubMed
Metadata
Title
Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation
Authors
D. Briem
W. Linhart
W. Lehmann
P. G. Begemann
G. Adam
U. Schumacher
D. M. Cullinane
J. M. Rueger
J. Windolf
Publication date
01-06-2006
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 6/2006
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-005-0992-5

Other articles of this Issue 6/2006

European Spine Journal 6/2006 Go to the issue