Skip to main content
Top
Published in: European Spine Journal 5/2003

01-10-2003 | Ideas and Technical Innovations

Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spine

Authors: Jean-Marc Mac-Thiong, Hubert Labelle, Marcel Rooze, Véronique Feipel, Carl-Eric Aubin

Published in: European Spine Journal | Issue 5/2003

Login to get access

Abstract

Insertion of pedicle screws in the thoracic spine is technically difficult and may lead to major complications. Although many computer-assisted systems have been developed to optimize pedicle screw insertion, these systems are expensive, not user-friendly and involve significant radiation from pre-operative computed tomographic (CT) scan imaging. This study describes and evaluates a transpedicular drill guide (TDG) designed to assist in the proper placement of pedicle screws in the thoracic spine. Pilot holes were made manually using the TDG in the thoracic spine (T1–T11) of three human cadavers before inserting 4.5-mm-diameter screws. CT scans followed by visual inspection of the spines were performed to evaluate the position of the screws. Five of 66 screws (7.6%) violated the pedicle wall: two (3.0%) medially and three (4.5%) laterally. The medial and lateral perforations were within 1 mm and 2 mm of the pedicle wall, respectively. The medial perforations were not at risk of causing neurological complications. No screw penetrated the superior or inferior pedicle wall. The TDG is easy to use and can decrease the incidence of misplaced thoracic pedicle screws. The TDG could be used as a complement to fluoroscopy in certain applications, especially for training surgeons.
Literature
1.
go back to reference Aebi M (1997) Point of view: anatomic relations of the thoracic pedicle to the adjacent neural structures. Spine 22:1557CrossRef Aebi M (1997) Point of view: anatomic relations of the thoracic pedicle to the adjacent neural structures. Spine 22:1557CrossRef
2.
go back to reference Amiot L-P, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 25:606–614PubMed Amiot L-P, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 25:606–614PubMed
3.
go back to reference Belmont Jr PJ, Klemme WR, Dhawan A, Polly Jr DW (2001) In vivo accuracy of thoracic pedicle screws. Spine 26:2340–2346CrossRefPubMed Belmont Jr PJ, Klemme WR, Dhawan A, Polly Jr DW (2001) In vivo accuracy of thoracic pedicle screws. Spine 26:2340–2346CrossRefPubMed
4.
go back to reference Bolger C, Wigfield C (2000) Image-guided surgery: applications to the cervical and thoracic spine and a review of the first 120 procedures. J Neurosurg 92 [Spine 2]:175–180 Bolger C, Wigfield C (2000) Image-guided surgery: applications to the cervical and thoracic spine and a review of the first 120 procedures. J Neurosurg 92 [Spine 2]:175–180
5.
go back to reference Cinotti G, Gumina S, Ripani M, Postacchini F (1999) Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws. Spine 24:114–119CrossRefPubMed Cinotti G, Gumina S, Ripani M, Postacchini F (1999) Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws. Spine 24:114–119CrossRefPubMed
6.
go back to reference Ebraheim NA, Jabaly G, Xu R, Yeasting RA (1997) Anatomic relations of the thoracic pedicle to the adjacent neural structures. Spine 22:1553–1556CrossRefPubMed Ebraheim NA, Jabaly G, Xu R, Yeasting RA (1997) Anatomic relations of the thoracic pedicle to the adjacent neural structures. Spine 22:1553–1556CrossRefPubMed
7.
go back to reference Ebraheim NA, Xu R, Ahmad M, Yeasting RA (1997) Projection of the thoracic pedicle and its morphometric analysis. Spine 22:233–238CrossRefPubMed Ebraheim NA, Xu R, Ahmad M, Yeasting RA (1997) Projection of the thoracic pedicle and its morphometric analysis. Spine 22:233–238CrossRefPubMed
8.
go back to reference Foley KT, Simon DA, Rampersaud R (2001) Virtual fluoroscopy: computer-assisted fluoroscopic navigation. Spine 26:347–351CrossRefPubMed Foley KT, Simon DA, Rampersaud R (2001) Virtual fluoroscopy: computer-assisted fluoroscopic navigation. Spine 26:347–351CrossRefPubMed
9.
go back to reference Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15:11–14PubMed Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15:11–14PubMed
10.
go back to reference Jonsson B, Sjostrom L, Olerud C, Andreasson I, Bring J, Rauschning W (1996) Outcome after limited posterior surgery for thoracic and lumbar spine metastases. Eur Spine J 5:36–44PubMed Jonsson B, Sjostrom L, Olerud C, Andreasson I, Bring J, Rauschning W (1996) Outcome after limited posterior surgery for thoracic and lumbar spine metastases. Eur Spine J 5:36–44PubMed
11.
go back to reference Kim KD, Johnson JP, Bloch BS O, Masciopinto JE (2001) Computer-assisted thoracic pedicle screw placement: an in vitro feasibility study. Spine 26:360–364CrossRefPubMed Kim KD, Johnson JP, Bloch BS O, Masciopinto JE (2001) Computer-assisted thoracic pedicle screw placement: an in vitro feasibility study. Spine 26:360–364CrossRefPubMed
12.
go back to reference Liljenqvist UR, Halm HF, Link TM (1997) Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine 22:2239–2245PubMed Liljenqvist UR, Halm HF, Link TM (1997) Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine 22:2239–2245PubMed
13.
go back to reference Liljenqvist U, Hackenberg L, Link T, Halm H (2001) Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine. Acta Orthop Belg 67:157–163PubMed Liljenqvist U, Hackenberg L, Link T, Halm H (2001) Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine. Acta Orthop Belg 67:157–163PubMed
14.
go back to reference Liljenqvist UR, Allkemper T, Hackenberg L, Link TM, Steinbeck J, Halm FH (2002) Analysis of vertebral morphology in idiopathic scoliosis with use of magnetic resonance imaging and multiplanar reconstructions. J Bone Joint Surg Am 84:359–368 Liljenqvist UR, Allkemper T, Hackenberg L, Link TM, Steinbeck J, Halm FH (2002) Analysis of vertebral morphology in idiopathic scoliosis with use of magnetic resonance imaging and multiplanar reconstructions. J Bone Joint Surg Am 84:359–368
15.
go back to reference Nolte L-P, Slomczykowski MA, Berlemann U (2000) A new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation. Eur Spine J 9:S78–S88PubMed Nolte L-P, Slomczykowski MA, Berlemann U (2000) A new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation. Eur Spine J 9:S78–S88PubMed
16.
go back to reference Papin P, Arlet V, Marchesi D, Rosenblatt B, Aebi M (1999) Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis. Eur Spine J 8:156–160PubMed Papin P, Arlet V, Marchesi D, Rosenblatt B, Aebi M (1999) Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis. Eur Spine J 8:156–160PubMed
17.
go back to reference Parent S, Labelle H, Skalli W, Latimer B, de Guise J (2002) Morphometric analysis of anatomic scoliotic specimens. Spine 27:2305-2311CrossRefPubMed Parent S, Labelle H, Skalli W, Latimer B, de Guise J (2002) Morphometric analysis of anatomic scoliotic specimens. Spine 27:2305-2311CrossRefPubMed
18.
go back to reference Reynolds Jr AF, Roberts PA, Pollay M, Stratemeier PH (1985) Quantitative anatomy of the thoracolumbar epidural space. Neurosurgery 17:905–907PubMed Reynolds Jr AF, Roberts PA, Pollay M, Stratemeier PH (1985) Quantitative anatomy of the thoracolumbar epidural space. Neurosurgery 17:905–907PubMed
19.
go back to reference Roy-Camille R, Saillant G, Mazel C (1986) Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates. Orthop Clin North Am 17:147–159PubMed Roy-Camille R, Saillant G, Mazel C (1986) Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates. Orthop Clin North Am 17:147–159PubMed
20.
go back to reference Suk S-I, Lee CK, Kim W-J, Chung Y-J, Park Y-B (1995) Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Spine 20:1399–1405PubMed Suk S-I, Lee CK, Kim W-J, Chung Y-J, Park Y-B (1995) Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Spine 20:1399–1405PubMed
21.
go back to reference Ugur HC, Attar A, Uz A, Tekdemir I, Egemen N, Genc Y (2001) Thoracic pedicle: surgical anatomic evaluation and relations. J Spinal Disord 14:39–45CrossRefPubMed Ugur HC, Attar A, Uz A, Tekdemir I, Egemen N, Genc Y (2001) Thoracic pedicle: surgical anatomic evaluation and relations. J Spinal Disord 14:39–45CrossRefPubMed
22.
go back to reference Vaccaro AR, Rizzolo SJ, Balderston RA, Allardyce TJ, Garfin SR, Dolinskas C, An HS (1995) Placement of pedicle screws in the thoracic spine. II. An anatomical and radiographic assessment. J Bone Joint Surg Am 77:1200–1206PubMed Vaccaro AR, Rizzolo SJ, Balderston RA, Allardyce TJ, Garfin SR, Dolinskas C, An HS (1995) Placement of pedicle screws in the thoracic spine. II. An anatomical and radiographic assessment. J Bone Joint Surg Am 77:1200–1206PubMed
23.
go back to reference Van Sint Jan S, Rooze M (1992) The thenar muscles. New findings. Surg Radiol Anat 14:325–329PubMed Van Sint Jan S, Rooze M (1992) The thenar muscles. New findings. Surg Radiol Anat 14:325–329PubMed
24.
go back to reference Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13:1012–1018PubMed Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13:1012–1018PubMed
25.
go back to reference Xu R, Ebraheim NA, Ou Y, Yeasting RA (1998) Anatomic considerations of pedicle screw placement in the thoracic spine. Roy-Camille technique versus open-lamina technique. Spine 23:1065–1068CrossRefPubMed Xu R, Ebraheim NA, Ou Y, Yeasting RA (1998) Anatomic considerations of pedicle screw placement in the thoracic spine. Roy-Camille technique versus open-lamina technique. Spine 23:1065–1068CrossRefPubMed
26.
go back to reference Xu R, Ebraheim NA, Shepherd ME, Yeasting RA (1999) Thoracic pedicle screw placement guided by computed tomographic measurements. J Spinal Disord 12:222–226PubMed Xu R, Ebraheim NA, Shepherd ME, Yeasting RA (1999) Thoracic pedicle screw placement guided by computed tomographic measurements. J Spinal Disord 12:222–226PubMed
27.
go back to reference Youkilis AS, Quint DJ, McGillicuddy JE, Papadopoulos SM (2001) Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery 48:771–778PubMed Youkilis AS, Quint DJ, McGillicuddy JE, Papadopoulos SM (2001) Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery 48:771–778PubMed
28.
go back to reference Zindrick MR, Wiltse LL, Doornik A, Widell EH, Knight GW, Patwardhan AG, Thomas JC, Rothman SL, Fields BT (1987) Analysis of the morphometric characteristics of the thoracic and lumbar pedicles. Spine 12:160–166PubMed Zindrick MR, Wiltse LL, Doornik A, Widell EH, Knight GW, Patwardhan AG, Thomas JC, Rothman SL, Fields BT (1987) Analysis of the morphometric characteristics of the thoracic and lumbar pedicles. Spine 12:160–166PubMed
Metadata
Title
Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spine
Authors
Jean-Marc Mac-Thiong
Hubert Labelle
Marcel Rooze
Véronique Feipel
Carl-Eric Aubin
Publication date
01-10-2003
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 5/2003
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-003-0549-4

Other articles of this Issue 5/2003

European Spine Journal 5/2003 Go to the issue

Announcements

October 2003