Skip to main content
Top
Published in: Comparative Clinical Pathology 1/2016

01-01-2016 | Original Article

Diagnostic accuracy of dual-source CT angiography for evaluation of coronary artery and comparative analysis of the DSCT angiography of the internal carotid artery plaque with the histopathological specimens

Authors: Babak Shekarchi, Marzieh Motevalli, Ali Mohammadzadeh, Morteza Noormohammadzadeh

Published in: Comparative Clinical Pathology | Issue 1/2016

Login to get access

Abstract

The purpose of this study was to investigate the diagnostic accuracy of a dual-source CT (DSCT) coronary angiography in parallel with a CT angiography. On the other hand, we compared the DSCT angiography of the internal carotid artery plaque with the histopathological specimens. Ninety patients underwent DSCT and an invasive coronary angiography (ICA). All segments were analyzed at 60 and 70 % of R-R interval initially. After finding the reconstruction interval, image quality was divided for each coronary segment on the four-point Likert scale. Also, of these patients, 30 cases that had neurological symptoms and carotid arteries also were evaluated. The degree of stenosis was assessed according to the North American Carotid Endarterectomy Trial (NASCET) criteria. A patient-specific analysis revealed that the method sensitivity was 98.59 %, specificity was 94.7 %, positive predictive value (PPV) was 98.57 %, negative predictive value (NPV) was 95 %, and accuracy was 97.7 %. Also, the kappa statistics did show high values in agreement with the histopathological findings (type III k = 0.82, types IV–V = 0.86, type VI = 0.81, type VII = 0.88, and type VIII = 0.67). Our results suggest that the DSCT has a high diagnostic accuracy for the evaluation of CAD and could demonstrate a high correlation between non-invasive imaging findings with DSCT and histopathological specimens.
Literature
go back to reference Achenbach S, Ropers D, Kuettner A, Flohr T, Ohnesorge B, Bruder H et al (2006) Contrast-enhanced coronary artery visualization by dual-source computed tomography—initial experience. Eur J Radiol 57(3):331–5CrossRefPubMed Achenbach S, Ropers D, Kuettner A, Flohr T, Ohnesorge B, Bruder H et al (2006) Contrast-enhanced coronary artery visualization by dual-source computed tomography—initial experience. Eur J Radiol 57(3):331–5CrossRefPubMed
go back to reference Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS et al (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40CrossRefPubMed Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS et al (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40CrossRefPubMed
go back to reference Becker CR, Knez A, Leber A, Hong C, Treede H, Wildhirt S et al (2000) Initial experiences with multislice detector spiral CT in diagnosis of arteriosclerosis of coronary vessels. Radiologe 40:118–122CrossRefPubMed Becker CR, Knez A, Leber A, Hong C, Treede H, Wildhirt S et al (2000) Initial experiences with multislice detector spiral CT in diagnosis of arteriosclerosis of coronary vessels. Radiologe 40:118–122CrossRefPubMed
go back to reference Fellner C, Lang W, Janka R, Wutke R, Bautz W, Fellner FA (2005) Magnetic resonance angiography of the carotid arteries using three different techniques: accuracy compared with intra arterial x-ray angiography and endarterectomy specimens. J Magn Reson Imaging 21(4):424–31CrossRefPubMed Fellner C, Lang W, Janka R, Wutke R, Bautz W, Fellner FA (2005) Magnetic resonance angiography of the carotid arteries using three different techniques: accuracy compared with intra arterial x-ray angiography and endarterectomy specimens. J Magn Reson Imaging 21(4):424–31CrossRefPubMed
go back to reference Hoffmann MH, Shi H, Manzke R et al (2005) Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology 234:86–97CrossRefPubMed Hoffmann MH, Shi H, Manzke R et al (2005) Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology 234:86–97CrossRefPubMed
go back to reference Johnson TR, Krauss B, Sedlmair M, Grasruck M, Bruder H, Morhard D et al (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17(6):1510–7CrossRefPubMed Johnson TR, Krauss B, Sedlmair M, Grasruck M, Bruder H, Morhard D et al (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17(6):1510–7CrossRefPubMed
go back to reference Kachelriess M, Ulzheimer S, Kalender WA (2000) ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart. Med Phys 27:1881–1902CrossRefPubMed Kachelriess M, Ulzheimer S, Kalender WA (2000) ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart. Med Phys 27:1881–1902CrossRefPubMed
go back to reference Lell M, Fellner C, Baum U, Hothorn T, Steiner R, Lang W et al (2007) Evaluation of carotid artery stenosis with multisection CT and MR imaging: influence of imaging modality and postprocessing. AJNR Am J Neuroradiol 28(1):104–10PubMed Lell M, Fellner C, Baum U, Hothorn T, Steiner R, Lang W et al (2007) Evaluation of carotid artery stenosis with multisection CT and MR imaging: influence of imaging modality and postprocessing. AJNR Am J Neuroradiol 28(1):104–10PubMed
go back to reference Leschka S, Wildermuth S, Boehm T et al (2006) Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology 241:378–385CrossRefPubMed Leschka S, Wildermuth S, Boehm T et al (2006) Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology 241:378–385CrossRefPubMed
go back to reference Leschka S, Scheffel H, Desbiolles L, Plass A, Gaemperli O, Valenta I et al (2007) Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing. Invest Radiol 42(8):543–9CrossRefPubMed Leschka S, Scheffel H, Desbiolles L, Plass A, Gaemperli O, Valenta I et al (2007) Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing. Invest Radiol 42(8):543–9CrossRefPubMed
go back to reference Martuscelli E, Romagnoli A, D’Eliseo A et al (2004) Accuracy of thin-slice computed tomography in the detection of coronary stenoses. Eur Heart J 25:1043–1048CrossRefPubMed Martuscelli E, Romagnoli A, D’Eliseo A et al (2004) Accuracy of thin-slice computed tomography in the detection of coronary stenoses. Eur Heart J 25:1043–1048CrossRefPubMed
go back to reference Meng L, Cui L, Cheng Y, Wu X, Tang Y, Wang Y, Xu F (2009) Effect of heart rate and coronary calcification on the diagnostic accuracy of the dual-source CT coronary angiography in patients with suspected coronary artery disease. Korean J Radiol 10:347–354CrossRefPubMedPubMedCentral Meng L, Cui L, Cheng Y, Wu X, Tang Y, Wang Y, Xu F (2009) Effect of heart rate and coronary calcification on the diagnostic accuracy of the dual-source CT coronary angiography in patients with suspected coronary artery disease. Korean J Radiol 10:347–354CrossRefPubMedPubMedCentral
go back to reference Mollet NR, Cademartiri F, Nieman K et al (2004) Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris. J Am Coll Cardiol 43:2265–2270CrossRefPubMed Mollet NR, Cademartiri F, Nieman K et al (2004) Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris. J Am Coll Cardiol 43:2265–2270CrossRefPubMed
go back to reference Muhlenbruch G, Behrendt FF, Eddahabi MA, Knackstedt C, Stanzel S, Das M, et al (2008) Which iodine concentration in chest CT?—A prospective study in 300 patients. Eur Radiol Muhlenbruch G, Behrendt FF, Eddahabi MA, Knackstedt C, Stanzel S, Das M, et al (2008) Which iodine concentration in chest CT?—A prospective study in 300 patients. Eur Radiol
go back to reference Naghavi M, Libby P, Falk E, Casscells SW, Litovsky S, Rumberger J et al (2003a) From vulnerable plaque to vulnerable patient: a call for new definitions and risk assessment strategies: part II. Circulation 108(15):1772–8CrossRefPubMed Naghavi M, Libby P, Falk E, Casscells SW, Litovsky S, Rumberger J et al (2003a) From vulnerable plaque to vulnerable patient: a call for new definitions and risk assessment strategies: part II. Circulation 108(15):1772–8CrossRefPubMed
go back to reference Naghavi M, Libby P, Falk E, Casscells SW, Litovsky S, Rumberger J et al (2003b) From vulnerable plaque to vulnerable patient: a call for new definitions and risk assessment strategies: part I. Circulation 108(14):1664–72CrossRefPubMed Naghavi M, Libby P, Falk E, Casscells SW, Litovsky S, Rumberger J et al (2003b) From vulnerable plaque to vulnerable patient: a call for new definitions and risk assessment strategies: part I. Circulation 108(14):1664–72CrossRefPubMed
go back to reference Naghavi M, Falk E, Hecht HS, Jamieson MJ, Kaul S, Berman D et al (2006) From vulnerable plaque to vulnerable patient—part III: executive summary of the Screening for Heart Attack Prevention and Education (SHAPE) Task Force report. Am J Cardiol 98(2A):2H–15HCrossRefPubMed Naghavi M, Falk E, Hecht HS, Jamieson MJ, Kaul S, Berman D et al (2006) From vulnerable plaque to vulnerable patient—part III: executive summary of the Screening for Heart Attack Prevention and Education (SHAPE) Task Force report. Am J Cardiol 98(2A):2H–15HCrossRefPubMed
go back to reference NASCET (1991) Clinical alert: benefit of carotid endarterectomy for patients with high-grade stenosis of the internal carotid artery. National Institute of Neurological Disorders and Stroke Stroke and Trauma Division. North American Symptomatic Carotid Endarterectomy Trial (NASCET) investigators. Stroke 22(6):816–7CrossRef NASCET (1991) Clinical alert: benefit of carotid endarterectomy for patients with high-grade stenosis of the internal carotid artery. National Institute of Neurological Disorders and Stroke Stroke and Trauma Division. North American Symptomatic Carotid Endarterectomy Trial (NASCET) investigators. Stroke 22(6):816–7CrossRef
go back to reference Nieman K, Oudkerk M, Rensing BJ et al (2001) Coronary angiography with multi-slice computed tomography. Lancet 357:599–603CrossRefPubMed Nieman K, Oudkerk M, Rensing BJ et al (2001) Coronary angiography with multi-slice computed tomography. Lancet 357:599–603CrossRefPubMed
go back to reference Nieman K, Rensing BJ, van Geuns RJ et al (2002) Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart 88:470–474CrossRefPubMedPubMedCentral Nieman K, Rensing BJ, van Geuns RJ et al (2002) Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart 88:470–474CrossRefPubMedPubMedCentral
go back to reference Ohnesorge B, Flohr T, Becker C, Kopp AF, Schoepf UJ, Baum U et al (2000) Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 217:564–571CrossRefPubMed Ohnesorge B, Flohr T, Becker C, Kopp AF, Schoepf UJ, Baum U et al (2000) Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 217:564–571CrossRefPubMed
go back to reference Pannu HK, Jacobs JE, Lai S, Fishman EK (2006) Coronary CT angiography with 64-MDCT: assessment of vessel visibility. AJR 187:119–126CrossRefPubMed Pannu HK, Jacobs JE, Lai S, Fishman EK (2006) Coronary CT angiography with 64-MDCT: assessment of vessel visibility. AJR 187:119–126CrossRefPubMed
go back to reference Reimann AJ, Rinck D, Birinci-Aydogan A, Scheuering M, Burgstahler C, Schroeder S et al (2007) Dual-source computed tomography: advances of improved temporal resolution in coronary plaque imaging. Invest Radiol 42(3):196–203CrossRefPubMed Reimann AJ, Rinck D, Birinci-Aydogan A, Scheuering M, Burgstahler C, Schroeder S et al (2007) Dual-source computed tomography: advances of improved temporal resolution in coronary plaque imaging. Invest Radiol 42(3):196–203CrossRefPubMed
go back to reference Ropers D, Baum U, Pohle K et al (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666CrossRefPubMed Ropers D, Baum U, Pohle K et al (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666CrossRefPubMed
go back to reference Schroeder S, Kopp AF, Baumbach A, Meisner C, Kuettner A, Georg C et al (2001) Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography. J Am Coll Cardiol 37(5):1430–5CrossRefPubMed Schroeder S, Kopp AF, Baumbach A, Meisner C, Kuettner A, Georg C et al (2001) Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography. J Am Coll Cardiol 37(5):1430–5CrossRefPubMed
go back to reference Shim SS, Kim Y, Lim SM (2005) Improvement of image quality with beta-blocker premedication on ECG-gated 16-MDCT coronary angiography. AJR 184:649–654CrossRefPubMed Shim SS, Kim Y, Lim SM (2005) Improvement of image quality with beta-blocker premedication on ECG-gated 16-MDCT coronary angiography. AJR 184:649–654CrossRefPubMed
go back to reference Taguchi K, Anno H (2000) High temporal resolution for multislice helical computed tomography. Med Phys 27:861–872CrossRefPubMed Taguchi K, Anno H (2000) High temporal resolution for multislice helical computed tomography. Med Phys 27:861–872CrossRefPubMed
go back to reference Vanninen RL, Manninen HI, Partanen PK, Tulla H, Vainio PA (1996) How should we estimate carotid stenosis using magnetic resonance angiography? Neuroradiology 38(4):299–305CrossRefPubMed Vanninen RL, Manninen HI, Partanen PK, Tulla H, Vainio PA (1996) How should we estimate carotid stenosis using magnetic resonance angiography? Neuroradiology 38(4):299–305CrossRefPubMed
go back to reference Wintermark M, Jawadi SS, Rapp JH, Tihan T, Tong E, Glidden DV et al (2008) High-resolution CT imaging of carotid artery atherosclerotic plaques. AJNR Am J Neuroradiol 29(5):875–82CrossRefPubMed Wintermark M, Jawadi SS, Rapp JH, Tihan T, Tong E, Glidden DV et al (2008) High-resolution CT imaging of carotid artery atherosclerotic plaques. AJNR Am J Neuroradiol 29(5):875–82CrossRefPubMed
Metadata
Title
Diagnostic accuracy of dual-source CT angiography for evaluation of coronary artery and comparative analysis of the DSCT angiography of the internal carotid artery plaque with the histopathological specimens
Authors
Babak Shekarchi
Marzieh Motevalli
Ali Mohammadzadeh
Morteza Noormohammadzadeh
Publication date
01-01-2016
Publisher
Springer London
Published in
Comparative Clinical Pathology / Issue 1/2016
Print ISSN: 1618-5641
Electronic ISSN: 1618-565X
DOI
https://doi.org/10.1007/s00580-015-2129-5

Other articles of this Issue 1/2016

Comparative Clinical Pathology 1/2016 Go to the issue