Comparison of catheter-over-needle and catheter-through-needle on leakage from the catheter insertion site during continuous femoral nerve block

Authors: Rika Nogawa, Tomoyuki Maruyama, Yoshiki Kimoto, Akinori Yamazaki, Tomoyuki Kawamata

Published in: Journal of Anesthesia | Issue 3/2018

Login to get access

Abstract

The aim of this study was to compare the incidences of leakage from the catheter insertion site during continuous femoral nerve block when using the catheter-through-needle, Contiplex Touhy™ (CT) and the newly developed catheter-over-needle, Contiplex C™ (CC). Forty adult patients who were scheduled to undergo continuous femoral nerve block for pain control following knee surgery were enrolled and were randomly assigned to a CT group or a CC group. After finishing surgery, a catheter for continuous femoral nerve block was placed using ultrasound. A catheter was advanced along the femoral nerve 5–6 cm beyond the needle tip. Then 0.25% levobupivacaine was continuously administered at a rate of 5 ml/h until 9:00 am on postoperative day 1. The incidence of leakage of the local anesthetic from the insertion site in the CT group was significantly higher than that in the CC group. In the CT group, leakage from the catheter insertion site was observed in 11 of 20 patients during the observation period. On the other hand, none of the patients in the CC group showed leakage. Contiplex C™ is more effective than Contiplex Touphy™ for prevention of leakage of local anesthetics from the insertion site during continuous femoral nerve block.
Literature
1.
go back to reference Paul JE, Arya A, Hurlburt L, Cheng J, Thabane L, Tidy A, Murthy Y. Femoral nerve block improves analgesia outcomes after total knee arthroplasty. Anesthesiology. 2010;113:1144–62.CrossRefPubMed Paul JE, Arya A, Hurlburt L, Cheng J, Thabane L, Tidy A, Murthy Y. Femoral nerve block improves analgesia outcomes after total knee arthroplasty. Anesthesiology. 2010;113:1144–62.CrossRefPubMed
2.
go back to reference Ilefeld BM. Continuous peripheral nerve blocks: a review of published evidence. Anesth Analg. 2011;113:904–25.CrossRef Ilefeld BM. Continuous peripheral nerve blocks: a review of published evidence. Anesth Analg. 2011;113:904–25.CrossRef
3.
go back to reference Davis AF, Segar EP, Murdoch J, Wright DE, Wilson IH. Epidural infusion or combined femoral and sciatic nerve blocks as perioperative analgesia for knee arthroplasty. Br J Anaesth. 2004;93:368–74.CrossRef Davis AF, Segar EP, Murdoch J, Wright DE, Wilson IH. Epidural infusion or combined femoral and sciatic nerve blocks as perioperative analgesia for knee arthroplasty. Br J Anaesth. 2004;93:368–74.CrossRef
4.
go back to reference Klein SM, Nielsen KC, Buckenmaler CC 3rd, Kamal AS, Rubin Y, Steele SM. 2-octyl cyanoacrylate glue for the fixation of continuous peripheral nerve catheters. Anesthesiology. 2003;98:590–1.CrossRefPubMed Klein SM, Nielsen KC, Buckenmaler CC 3rd, Kamal AS, Rubin Y, Steele SM. 2-octyl cyanoacrylate glue for the fixation of continuous peripheral nerve catheters. Anesthesiology. 2003;98:590–1.CrossRefPubMed
5.
go back to reference Boezaart AP, de Beer JF, du Toit C, van Rooyen K. A new technique of continuous interscalene nerve block. Can J Anaesth. 1999;46:275–81.CrossRefPubMed Boezaart AP, de Beer JF, du Toit C, van Rooyen K. A new technique of continuous interscalene nerve block. Can J Anaesth. 1999;46:275–81.CrossRefPubMed
6.
go back to reference Yu B, Hu X, Zou T, He M, Cai G. Effects of postoperative continuous femoral nerve block analgesia with Braun continuous peripheral nerve block catheter set versus novel needle–over–cannula after total knee arthroplasty. Med Sci Monit. 2015;21:1843–9.CrossRefPubMedPubMedCentral Yu B, Hu X, Zou T, He M, Cai G. Effects of postoperative continuous femoral nerve block analgesia with Braun continuous peripheral nerve block catheter set versus novel needle–over–cannula after total knee arthroplasty. Med Sci Monit. 2015;21:1843–9.CrossRefPubMedPubMedCentral
Metadata
Title
Comparison of catheter-over-needle and catheter-through-needle on leakage from the catheter insertion site during continuous femoral nerve block
Authors
Rika Nogawa
Tomoyuki Maruyama
Yoshiki Kimoto
Akinori Yamazaki
Tomoyuki Kawamata
Publication date
01-06-2018
Publisher
Springer Japan
Published in
Journal of Anesthesia / Issue 3/2018
Print ISSN: 0913-8668
Electronic ISSN: 1438-8359
DOI
https://doi.org/10.1007/s00540-018-2479-7

Other articles of this Issue 3/2018

Journal of Anesthesia 3/2018 Go to the issue