Influence of tidal volume for stroke volume variation to predict fluid responsiveness in patients undergoing one-lung ventilation

Authors: Koichi Suehiro, Ryu Okutani

Published in: Journal of Anesthesia | Issue 5/2011

Login to get access

Abstract

We designed this study to determine the predictive value for fluid responsiveness of stroke volume variation (SVV) in patients undergoing one-lung ventilation (OLV), ventilated at different tidal volumes. All patients scheduled for pulmonary lobectomy were randomized into two groups according to their tidal volume [group H: tidal volume 8 ml/kg (n = 36); group L: tidal volume 6 ml/kg (n = 37)]. After starting OLV, volume loading was performed by administration of 500 ml 6% hydroxyethylated starch for 30 min. Hemodynamic variables were measured before and after volume loading using the Vigileo-FloTrac system. Patients in both groups were divided into fluid responders and non-responders, and responders were defined as those who demonstrated an increase in cardiac index ≥15% after volume expansion. The area under the receiver operating characteristic curve for SVV to discriminate between responders and non-responders was 0.776 in group H and 0.648 in group L. The optimal threshold value of SVV was 10.5% (sensitivity, 85.7%; specificity, 66.7%) in group H and 8% (sensitivity, 69.5%; specificity, 64.3%) in group L. We found that SVV could predict fluid responsiveness in patients undergoing OLV with acceptable levels of sensitivity and specificity only when tidal volume is at least 8 ml/kg.
Literature
1.
go back to reference Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? Chest. 2008;134:172–8.PubMedCrossRef Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? Chest. 2008;134:172–8.PubMedCrossRef
2.
go back to reference Pinsky MR, Teboul JL. Assessment of indices of preload and volume responsiveness. Curr Opin Crit Care. 2005;11:235–9.PubMedCrossRef Pinsky MR, Teboul JL. Assessment of indices of preload and volume responsiveness. Curr Opin Crit Care. 2005;11:235–9.PubMedCrossRef
3.
go back to reference Michard F. Changes in arterial pressure during mechanical ventilation. Anesthesiology. 2005;103:419–28.PubMedCrossRef Michard F. Changes in arterial pressure during mechanical ventilation. Anesthesiology. 2005;103:419–28.PubMedCrossRef
4.
go back to reference Wiesenack C, Fiegl C, Keyser A, Prasser C, Keyl C. Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients. Eur J Anaesthesiol. 2005;22:658–65.PubMedCrossRef Wiesenack C, Fiegl C, Keyser A, Prasser C, Keyl C. Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients. Eur J Anaesthesiol. 2005;22:658–65.PubMedCrossRef
5.
go back to reference Rex S, Brose S, Metzelder S, Huneke R, Schalte G, Autschbach R, Rossaint R, Buhre W. Prediction of fluid responsiveness in patients during cardiac surgery. Br J Anaesth. 2004;93:782–8.PubMedCrossRef Rex S, Brose S, Metzelder S, Huneke R, Schalte G, Autschbach R, Rossaint R, Buhre W. Prediction of fluid responsiveness in patients during cardiac surgery. Br J Anaesth. 2004;93:782–8.PubMedCrossRef
6.
go back to reference Rocca GD, Costa MG, Chiarandini P, Bertossi G, Lugano M, Pompei L, Coccia C, Sainz-Barriga M, Pietropaoli P. Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions. J Cardiothorac Vasc Anesth. 2008;22:681–7.PubMedCrossRef Rocca GD, Costa MG, Chiarandini P, Bertossi G, Lugano M, Pompei L, Coccia C, Sainz-Barriga M, Pietropaoli P. Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions. J Cardiothorac Vasc Anesth. 2008;22:681–7.PubMedCrossRef
7.
go back to reference Breukers RM, Sepehrkhouy S, Spiegelenberg SR, Groeneveld ABJ. Cardiac output measured by a new arterial waveform analysis method without calibration compared with thermodilution after cardiac surgery. J Cardiothorac Vasc Anesth. 2007;21:632–5.PubMedCrossRef Breukers RM, Sepehrkhouy S, Spiegelenberg SR, Groeneveld ABJ. Cardiac output measured by a new arterial waveform analysis method without calibration compared with thermodilution after cardiac surgery. J Cardiothorac Vasc Anesth. 2007;21:632–5.PubMedCrossRef
8.
go back to reference Manecke GR, Auger WR. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration. J Cardiothorac Vasc Anesth. 2007;21:3–7.PubMedCrossRef Manecke GR, Auger WR. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration. J Cardiothorac Vasc Anesth. 2007;21:3–7.PubMedCrossRef
9.
go back to reference Lorsomradee S, Cromheecke S, Hert SG. Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform. J Cardiothorac Vasc Anesth. 2007;21:636–43.PubMedCrossRef Lorsomradee S, Cromheecke S, Hert SG. Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform. J Cardiothorac Vasc Anesth. 2007;21:636–43.PubMedCrossRef
10.
go back to reference Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Henaine R, Lehot JJ. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg. 2009;108:513–7.PubMedCrossRef Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Henaine R, Lehot JJ. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg. 2009;108:513–7.PubMedCrossRef
11.
go back to reference Suehiro K, Okutani R. Stroke volume variation as predictor of fluid responsiveness in patients undergoing one-lung ventilation. J Cardiothorac Vasc Anesth. 2010;24:772–5.PubMedCrossRef Suehiro K, Okutani R. Stroke volume variation as predictor of fluid responsiveness in patients undergoing one-lung ventilation. J Cardiothorac Vasc Anesth. 2010;24:772–5.PubMedCrossRef
12.
go back to reference Reuter DA, Bayerlein J, Goepfert MSG, Weis FC, Kilger E, Lamn P, Goetz AE. Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med. 2003;29:476–80.PubMed Reuter DA, Bayerlein J, Goepfert MSG, Weis FC, Kilger E, Lamn P, Goetz AE. Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med. 2003;29:476–80.PubMed
13.
go back to reference Szold A, Pizov R, Segal E, Perel A. The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs. Intensive Care Med. 1989;15:368–71.PubMedCrossRef Szold A, Pizov R, Segal E, Perel A. The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs. Intensive Care Med. 1989;15:368–71.PubMedCrossRef
14.
go back to reference De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variation to predict fluid responsiveness: influence of tidal volume. Intensive Care Med. 2005;31:517–23.PubMedCrossRef De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variation to predict fluid responsiveness: influence of tidal volume. Intensive Care Med. 2005;31:517–23.PubMedCrossRef
15.
go back to reference Romand JA, Shi W, Pinsky MR. Cardiopulmonary effects of positive pressure ventilation during acute lung injury. Chest. 1995;108:1041–8.PubMedCrossRef Romand JA, Shi W, Pinsky MR. Cardiopulmonary effects of positive pressure ventilation during acute lung injury. Chest. 1995;108:1041–8.PubMedCrossRef
Metadata
Title
Influence of tidal volume for stroke volume variation to predict fluid responsiveness in patients undergoing one-lung ventilation
Authors
Koichi Suehiro
Ryu Okutani
Publication date
01-10-2011
Publisher
Springer Japan
Published in
Journal of Anesthesia / Issue 5/2011
Print ISSN: 0913-8668
Electronic ISSN: 1438-8359
DOI
https://doi.org/10.1007/s00540-011-1200-x

Other articles of this Issue 5/2011

Journal of Anesthesia 5/2011 Go to the issue