01-02-2011 | Short Communication

Validation of inflationary non-invasive blood pressure monitoring in adult surgical patients

Authors: Jun Onodera, Yoshifumi Kotake, Mitsue Fukuda, Rie Yasumura, Fujiko Oda, Nobukazu Sato, Ryoichi Ochiai, Takashi Usuda, Naoki Kobayashi, Sunao Takeda

Published in: Journal of Anesthesia | Issue 1/2011

Login to get access

Abstract

Oscillometric determination of blood pressure may be advantageous, as cuff inflation requires lower cuff pressure and shorter duration than deflation. In this observational study, we compared the blood pressure value, cuff pressure, and duration of cuff inflation between a prototype of inflationary non-invasive blood pressure (NIBP) and conventional deflationary NIBP in adult patients during anesthesia. Three hundred and twenty-three pairs of measurements were obtained from 64 subjects. The bias and precision of systolic pressure and diastolic pressure were 2.9 ± 8.3 and 5.6 ± 6.1 mmHg, respectively. Inflationary NIBP could better determine NIBP with lower cuff pressure than deflationary NIBP (124 ± 22 vs. 160 ± 33 mmHg, p < 0.05). Inflationary NIBP could also determine NIBP more quickly (13.0 ± 2.3 vs. 32.7 ± 13.6 s, p < 0.05). These data suggest that inflationary NIBP may reduce cuff-related discomfort and complications, and has reasonable accuracy compared to deflationary NIBP in adult surgical patients.
Literature
1.
go back to reference Weiss BM, Pasch T. Measurement of systemic arterial pressure. Curr Opin Anaesthesiol. 1997;10:459–66.CrossRef Weiss BM, Pasch T. Measurement of systemic arterial pressure. Curr Opin Anaesthesiol. 1997;10:459–66.CrossRef
2.
go back to reference van Montfrans GA. Oscillometric blood pressure measurement: progress and problems. Blood Press Monit. 2001;6:287–90.CrossRefPubMed van Montfrans GA. Oscillometric blood pressure measurement: progress and problems. Blood Press Monit. 2001;6:287–90.CrossRefPubMed
3.
go back to reference Bickler PE, Schapera A, Bainton CR. Acute radial nerve injury from use of an automatic blood pressure monitor. Anesthesiology. 1990;73:186–8.CrossRefPubMed Bickler PE, Schapera A, Bainton CR. Acute radial nerve injury from use of an automatic blood pressure monitor. Anesthesiology. 1990;73:186–8.CrossRefPubMed
4.
go back to reference Sutin KM, Longaker MT, Wahlander S, Kasabian AK, Capan LM. Acute biceps compartment syndrome associated with the use of a noninvasive blood pressure monitor. Anesth Analg. 1996;83:1345–6.CrossRefPubMed Sutin KM, Longaker MT, Wahlander S, Kasabian AK, Capan LM. Acute biceps compartment syndrome associated with the use of a noninvasive blood pressure monitor. Anesth Analg. 1996;83:1345–6.CrossRefPubMed
5.
go back to reference Golara M, Jones C, Randhawa M, Shennan AH. Inflationary oscillometric blood pressure monitoring: validation of the OMRON-MIT. Blood Press Monit. 2002;7:325–8.CrossRefPubMed Golara M, Jones C, Randhawa M, Shennan AH. Inflationary oscillometric blood pressure monitoring: validation of the OMRON-MIT. Blood Press Monit. 2002;7:325–8.CrossRefPubMed
6.
go back to reference Golara M, Benedict A, Jones C, Randhawa M, Poston L, Shennan AH. Inflationary oscillometry provides accurate measurement of blood pressure in pre-eclampsia. BJOG. 2002;109:1143–7.CrossRefPubMed Golara M, Benedict A, Jones C, Randhawa M, Poston L, Shennan AH. Inflationary oscillometry provides accurate measurement of blood pressure in pre-eclampsia. BJOG. 2002;109:1143–7.CrossRefPubMed
7.
go back to reference Munkhaugen J, Lydersen S, Wideroe TE, Hallan S. Blood pressure reference values in adolescents: methodological aspects and suggestions for Northern Europe tables based on the Nord-Trondelag Health Study II. J Hypertens. 2008;26:1912–8.CrossRefPubMed Munkhaugen J, Lydersen S, Wideroe TE, Hallan S. Blood pressure reference values in adolescents: methodological aspects and suggestions for Northern Europe tables based on the Nord-Trondelag Health Study II. J Hypertens. 2008;26:1912–8.CrossRefPubMed
8.
go back to reference de Greeff A, Beg Z, Gangji Z, Dorney E, Shennan AH. Accuracy of inflationary versus deflationary oscillometry in pregnancy and preeclampsia: OMRON-MIT versus OMRON-M7. Blood Press Monit. 2009;14:37–40.CrossRefPubMed de Greeff A, Beg Z, Gangji Z, Dorney E, Shennan AH. Accuracy of inflationary versus deflationary oscillometry in pregnancy and preeclampsia: OMRON-MIT versus OMRON-M7. Blood Press Monit. 2009;14:37–40.CrossRefPubMed
9.
go back to reference Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, Jones DW, Kurtz T, Sheps SG, Roccella EJ. Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension. 2005;45:142–61.PubMed Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, Jones DW, Kurtz T, Sheps SG, Roccella EJ. Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension. 2005;45:142–61.PubMed
10.
go back to reference Manual, electronic or automated sphygmomanometers. Arlington, VA: American National Standards Institutes, Inc./Association for the Advancement of Medical Instrumentation; 2002 (SP10). Manual, electronic or automated sphygmomanometers. Arlington, VA: American National Standards Institutes, Inc./Association for the Advancement of Medical Instrumentation; 2002 (SP10).
11.
Metadata
Title
Validation of inflationary non-invasive blood pressure monitoring in adult surgical patients
Authors
Jun Onodera
Yoshifumi Kotake
Mitsue Fukuda
Rie Yasumura
Fujiko Oda
Nobukazu Sato
Ryoichi Ochiai
Takashi Usuda
Naoki Kobayashi
Sunao Takeda
Publication date
01-02-2011
Publisher
Springer Japan
Published in
Journal of Anesthesia / Issue 1/2011
Print ISSN: 0913-8668
Electronic ISSN: 1438-8359
DOI
https://doi.org/10.1007/s00540-010-1067-2

Other articles of this Issue 1/2011

Journal of Anesthesia 1/2011 Go to the issue