Background

Fluorescence-based enhanced reality (FLER) is a computer-based quantification method of fluorescence angiographies to evaluate bowel perfusion. The aim of this prospective trial was to assess the clinical feasibility and to correlate FLER with metabolic markers of perfusion, during colorectal resections.

Methods

FLER analysis and visualization was performed in 22 patients (diverticulitis n = 17; colorectal cancer n = 5) intra- and extra-abdominally during distal and proximal resection, respectively. The fluorescence signal of indocyanine green (0.2 mg/kg) was captured using a near-infrared camera and computed to create a virtual color-coded cartography. This was overlaid onto the bowel (enhanced reality). It helped to identify regions of interest (ROIs) where samples were subsequently obtained. Resections were performed strictly guided according to clinical decision. On the surgical specimen, samplings were made at different ROIs to measure intestinal lactates (mmol/L) and mitochondria efficiency as acceptor control ratio (ACR).

Results

The native (unquantified) fluorescent signal diffused to obvious ischemic areas during the distal appreciation. Proximally, a lower diffusion of ICG was observed. Five anastomotic complications occurred. The expected values of local capillary lactates were correlated with the measured values both proximally (3.62 ± 2.48 expected vs. 3.17 ± 2.8 actual; rho 0.89; p = 0.0006) and distally (4.5 ± 3 expected vs. 4 ± 2.5 actual; rho 0.73; p = 0.0021). FLER values correlated with ACR at the proximal site (rho 0.76; p = 0.04) and at the ischemic zone (rho 0.71; p = 0.01). In complicated cases, lactates at the proximal resection site were higher (5.8 ± 4.5) as opposed to uncomplicated cases (2.45 ± 1.5; p = 0.008). ACR was reduced proximally in complicated (1.3 ± 0.18) vs. uncomplicated cases (1.68 ± 0.3; p = 0.023).

Conclusions

FLER allows to image the quantified fluorescence signal in augmented reality and provides a reproducible estimation of bowel perfusion (NCT02626091).
Appendix
Available only for authorised users
Literature
1.
go back to reference Blanco-Colino R, Espin-Basany E (2018) Intraoperative use of ICG fluorescence imaging to reduce the risk of anastomotic leakage in colorectal surgery: a systematic review and meta-analysis. Tech Coloproctol 22(1):15–23CrossRef Blanco-Colino R, Espin-Basany E (2018) Intraoperative use of ICG fluorescence imaging to reduce the risk of anastomotic leakage in colorectal surgery: a systematic review and meta-analysis. Tech Coloproctol 22(1):15–23CrossRef
2.
go back to reference Baiocchi GL, Diana M, Boni L (2018) Indocyanine green-based fluorescence imaging in visceral and hepatobiliary and pancreatic surgery: state of the art and future directions. World J Gastroenterol 24(27):2921–2930CrossRef Baiocchi GL, Diana M, Boni L (2018) Indocyanine green-based fluorescence imaging in visceral and hepatobiliary and pancreatic surgery: state of the art and future directions. World J Gastroenterol 24(27):2921–2930CrossRef
3.
go back to reference van Manen L, Handgraaf HJM, Diana M et al (2018) A practical guide for the use of indocyanine green and methylene blue in fluorescence-guided abdominal surgery. J Surg Oncol 118(2):283–300CrossRef van Manen L, Handgraaf HJM, Diana M et al (2018) A practical guide for the use of indocyanine green and methylene blue in fluorescence-guided abdominal surgery. J Surg Oncol 118(2):283–300CrossRef
4.
go back to reference Jafari MD, Wexner SD, Martz JE et al (2015) Perfusion assessment in laparoscopic left-sided/anterior resection (PILLAR II): a multi-institutional study. J Am Coll Surg 220(1):82–92CrossRef Jafari MD, Wexner SD, Martz JE et al (2015) Perfusion assessment in laparoscopic left-sided/anterior resection (PILLAR II): a multi-institutional study. J Am Coll Surg 220(1):82–92CrossRef
5.
go back to reference Ris F, Liot E, Buchs NC et al (2018) Multicentre phase II trial of near-infrared imaging in elective colorectal surgery. Br J Surg 105(10):1359–1367CrossRef Ris F, Liot E, Buchs NC et al (2018) Multicentre phase II trial of near-infrared imaging in elective colorectal surgery. Br J Surg 105(10):1359–1367CrossRef
6.
go back to reference Kudszus S, Roesel C, Schachtrupp A et al (2010) Intraoperative laser fluorescence angiography in colorectal surgery: a noninvasive analysis to reduce the rate of anastomotic leakage. Langenbecks Arch Surg 395(8):1025–1030CrossRef Kudszus S, Roesel C, Schachtrupp A et al (2010) Intraoperative laser fluorescence angiography in colorectal surgery: a noninvasive analysis to reduce the rate of anastomotic leakage. Langenbecks Arch Surg 395(8):1025–1030CrossRef
7.
go back to reference Kim JC, Lee JL, Yoon YS et al (2016) Utility of indocyanine-green fluorescent imaging during robot-assisted sphincter-saving surgery on rectal cancer patients. Int J Med Robot 12(4):710–717CrossRef Kim JC, Lee JL, Yoon YS et al (2016) Utility of indocyanine-green fluorescent imaging during robot-assisted sphincter-saving surgery on rectal cancer patients. Int J Med Robot 12(4):710–717CrossRef
8.
go back to reference Kin C, Vo H, Welton L et al (2015) Equivocal effect of intraoperative fluorescence angiography on colorectal anastomotic leaks. Dis Colon Rectum 58(6):582–587CrossRef Kin C, Vo H, Welton L et al (2015) Equivocal effect of intraoperative fluorescence angiography on colorectal anastomotic leaks. Dis Colon Rectum 58(6):582–587CrossRef
9.
go back to reference Jafari MD, Lee KH, Halabi WJ et al (2013) The use of indocyanine green fluorescence to assess anastomotic perfusion during robotic assisted laparoscopic rectal surgery. Surg Endosc 27(8):3003–3008CrossRef Jafari MD, Lee KH, Halabi WJ et al (2013) The use of indocyanine green fluorescence to assess anastomotic perfusion during robotic assisted laparoscopic rectal surgery. Surg Endosc 27(8):3003–3008CrossRef
10.
go back to reference Boni L, Fingerhut A, Marzorati A et al (2017) Indocyanine green fluorescence angiography during laparoscopic low anterior resection: results of a case-matched study. Surg Endosc 31(4):1836–1840CrossRef Boni L, Fingerhut A, Marzorati A et al (2017) Indocyanine green fluorescence angiography during laparoscopic low anterior resection: results of a case-matched study. Surg Endosc 31(4):1836–1840CrossRef
11.
go back to reference De Nardi P, Elmore U, Maggi G et al (2019) Intraoperative angiography with indocyanine green to assess anastomosis perfusion in patients undergoing laparoscopic colorectal resection: results of a multicenter randomized controlled trial. Surg Endosc 34(1):53–60CrossRef De Nardi P, Elmore U, Maggi G et al (2019) Intraoperative angiography with indocyanine green to assess anastomosis perfusion in patients undergoing laparoscopic colorectal resection: results of a multicenter randomized controlled trial. Surg Endosc 34(1):53–60CrossRef
12.
go back to reference van den Bos J, Al-Taher M, Schols RM et al (2018) Near-infrared fluorescence imaging for real-time intraoperative guidance in anastomotic colorectal surgery: a systematic review of literature. J Laparoendosc Adv Surg Tech A 28(2):157–167CrossRef van den Bos J, Al-Taher M, Schols RM et al (2018) Near-infrared fluorescence imaging for real-time intraoperative guidance in anastomotic colorectal surgery: a systematic review of literature. J Laparoendosc Adv Surg Tech A 28(2):157–167CrossRef
13.
go back to reference Wada T, Kawada K, Takahashi R et al (2017) ICG fluorescence imaging for quantitative evaluation of colonic perfusion in laparoscopic colorectal surgery. Surg Endosc 31(10):4184–4193CrossRef Wada T, Kawada K, Takahashi R et al (2017) ICG fluorescence imaging for quantitative evaluation of colonic perfusion in laparoscopic colorectal surgery. Surg Endosc 31(10):4184–4193CrossRef
14.
go back to reference Son GM, Kwon MS, Kim Y et al (2019) Quantitative analysis of colon perfusion pattern using indocyanine green (ICG) angiography in laparoscopic colorectal surgery. Surg Endosc 33(5):1640–1649CrossRef Son GM, Kwon MS, Kim Y et al (2019) Quantitative analysis of colon perfusion pattern using indocyanine green (ICG) angiography in laparoscopic colorectal surgery. Surg Endosc 33(5):1640–1649CrossRef
15.
go back to reference Nerup N, Andersen HS, Ambrus R et al (2017) Quantification of fluorescence angiography in a porcine model. Langenbecks Arch Surg 402(4):655–662CrossRef Nerup N, Andersen HS, Ambrus R et al (2017) Quantification of fluorescence angiography in a porcine model. Langenbecks Arch Surg 402(4):655–662CrossRef
16.
go back to reference Diana M, Noll E, Agnus V et al (2017) Reply to letter: "Enhanced reality fluorescence videography to assess bowel perfusion: the cybernetic eye". Ann Surg 265(4):e49–e52CrossRef Diana M, Noll E, Agnus V et al (2017) Reply to letter: "Enhanced reality fluorescence videography to assess bowel perfusion: the cybernetic eye". Ann Surg 265(4):e49–e52CrossRef
17.
go back to reference Diana M, Noll E, Diemunsch P et al (2014) Enhanced-reality video fluorescence: a real-time assessment of intestinal viability. Ann Surg 259(4):700–707CrossRef Diana M, Noll E, Diemunsch P et al (2014) Enhanced-reality video fluorescence: a real-time assessment of intestinal viability. Ann Surg 259(4):700–707CrossRef
18.
go back to reference Watanabe J, Ishibe A, Suwa Y et al (2019) Indocyanine green fluorescence imaging to reduce the risk of anastomotic leakage in laparoscopic low anterior resection for rectal cancer: a propensity score-matched cohort study. Surg Endosc 34(1):202–208CrossRef Watanabe J, Ishibe A, Suwa Y et al (2019) Indocyanine green fluorescence imaging to reduce the risk of anastomotic leakage in laparoscopic low anterior resection for rectal cancer: a propensity score-matched cohort study. Surg Endosc 34(1):202–208CrossRef
19.
go back to reference Diana M (2017) Enabling precision digestive surgery with fluorescence imaging. Transl Gastroenterol Hepatol 2:97CrossRef Diana M (2017) Enabling precision digestive surgery with fluorescence imaging. Transl Gastroenterol Hepatol 2:97CrossRef
20.
go back to reference Mascagni P, Longo F, Barberio M et al (2018) New intraoperative imaging technologies: innovating the surgeon's eye toward surgical precision. J Surg Oncol 118(2):265–282CrossRef Mascagni P, Longo F, Barberio M et al (2018) New intraoperative imaging technologies: innovating the surgeon's eye toward surgical precision. J Surg Oncol 118(2):265–282CrossRef
21.
go back to reference Diana M, Halvax P, Dallemagne B et al (2014) Real-time navigation by fluorescence-based enhanced reality for precise estimation of future anastomotic site in digestive surgery. Surg Endosc 28(11):3108–3118CrossRef Diana M, Halvax P, Dallemagne B et al (2014) Real-time navigation by fluorescence-based enhanced reality for precise estimation of future anastomotic site in digestive surgery. Surg Endosc 28(11):3108–3118CrossRef
22.
go back to reference Diana M, Dallemagne B, Chung H et al (2014) Probe-based confocal laser endomicroscopy and fluorescence-based enhanced reality for real-time assessment of intestinal microcirculation in a porcine model of sigmoid ischemia. Surg Endosc 28(11):3224–3233CrossRef Diana M, Dallemagne B, Chung H et al (2014) Probe-based confocal laser endomicroscopy and fluorescence-based enhanced reality for real-time assessment of intestinal microcirculation in a porcine model of sigmoid ischemia. Surg Endosc 28(11):3224–3233CrossRef
23.
go back to reference Diana M, Agnus V, Halvax P et al (2015) Intraoperative fluorescence-based enhanced reality laparoscopic real-time imaging to assess bowel perfusion at the anastomotic site in an experimental model. Br J Surg 102(2):e169–e176CrossRef Diana M, Agnus V, Halvax P et al (2015) Intraoperative fluorescence-based enhanced reality laparoscopic real-time imaging to assess bowel perfusion at the anastomotic site in an experimental model. Br J Surg 102(2):e169–e176CrossRef
24.
go back to reference Quero G, Lapergola A, Barberio M et al (2019) Discrimination between arterial and venous bowel ischemia by computer-assisted analysis of the fluorescent signal. Surg Endosc 33(6):1988–1997CrossRef Quero G, Lapergola A, Barberio M et al (2019) Discrimination between arterial and venous bowel ischemia by computer-assisted analysis of the fluorescent signal. Surg Endosc 33(6):1988–1997CrossRef
25.
go back to reference Gosvig K, Jensen SS, Qvist N et al (2019) Remote computer-assisted analysis of ICG fluorescence signal for evaluation of small intestinal anastomotic perfusion: a blinded, randomized, experimental trial. Surg Endosc 34(5):2095–2102CrossRef Gosvig K, Jensen SS, Qvist N et al (2019) Remote computer-assisted analysis of ICG fluorescence signal for evaluation of small intestinal anastomotic perfusion: a blinded, randomized, experimental trial. Surg Endosc 34(5):2095–2102CrossRef
27.
go back to reference Barberio M, Longo F, Fiorillo C et al (2020) HYPerspectral enhanced reality (HYPER): a physiology-based surgical guidance tool. Surg Endosc 34(4):1736–1744CrossRef Barberio M, Longo F, Fiorillo C et al (2020) HYPerspectral enhanced reality (HYPER): a physiology-based surgical guidance tool. Surg Endosc 34(4):1736–1744CrossRef
29.
go back to reference Schlagowski AI, Singh F, Charles AL et al (2014) Mitochondrial uncoupling reduces exercise capacity despite several skeletal muscle metabolic adaptations. J Appl Physiol 116(4):364–375CrossRef Schlagowski AI, Singh F, Charles AL et al (2014) Mitochondrial uncoupling reduces exercise capacity despite several skeletal muscle metabolic adaptations. J Appl Physiol 116(4):364–375CrossRef
30.
go back to reference Diana M, Noll E, Diemunsch P et al (2015) Metabolism-guided bowel resection: potential role and accuracy of instant capillary lactates to identify the optimal resection site. Surg Innov 22(5):453–461CrossRef Diana M, Noll E, Diemunsch P et al (2015) Metabolism-guided bowel resection: potential role and accuracy of instant capillary lactates to identify the optimal resection site. Surg Innov 22(5):453–461CrossRef
31.
go back to reference Hayami S, Matsuda K, Iwamoto H et al (2019) Visualization and quantification of anastomotic perfusion in colorectal surgery using near-infrared fluorescence. Tech Coloproctol 23(10):973–980CrossRef Hayami S, Matsuda K, Iwamoto H et al (2019) Visualization and quantification of anastomotic perfusion in colorectal surgery using near-infrared fluorescence. Tech Coloproctol 23(10):973–980CrossRef
Metadata
Title
Computer-assisted quantification and visualization of bowel perfusion using fluorescence-based enhanced reality in left-sided colonic resections
Authors
Antonio D’Urso
Vincent Agnus
Manuel Barberio
Barbara Seeliger
Francesco Marchegiani
Anne-Laure Charles
Bernard Geny
Jacques Marescaux
Didier Mutter
Michele Diana
Publication date
01-08-2021
Publisher
Springer US
Published in
Surgical Endoscopy / Issue 8/2021
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-020-07922-9

Other articles of this Issue 8/2021

Surgical Endoscopy 8/2021 Go to the issue