Skip to main content
Top
Published in: Surgical Endoscopy 5/2018

01-05-2018

The influence of the different forms of appendix base closure on patient outcome in laparoscopic appendectomy: a randomized trial

Authors: Samir Delibegović, Zlatan Mehmedovic

Published in: Surgical Endoscopy | Issue 5/2018

Login to get access

Abstract

Background

During laparoscopic appendectomy, the base of the appendix is usually secured by loop ligature or stapling device. Hem-o-lok and DS clips have been shown as alternative techniques. The aim of this study was to compare the clinical outcomes of various forms of securing the base of the appendix, in order to find the most suitable method.

Patients and methods

The study included 120 patients with acute appendicitis randomly divided into four groups with 30 patients in each. In the first group, the base of the appendix was secured using an Endoloop, in the second group using a stapling device, in the third group using Hem-o-lok, and in the fourth group using a DS clip. The primary outcome was overall morbidity following securing the base of the appendix. Secondary outcomes were time of application and operative procedure, total length of stay, and surgical outcome.

Results

No morbidity was recorded in any group. The time of application was significantly longer in the Endoloop group than in the Stapler (P < 0.0001), Hem-o-lok (P < 0.0001), and DS clips (P < 0.0001) groups. The time of application in the Stapler group was significantly shorter than in the Hem-o-lok (P < 0.0001) and the DS clips (P < 0.0001) groups. The time of the operative procedure was significantly longer in the Endoloop than in the Stapler group (P < 0.0001). The time of the operative procedure in the Stapler group was significantly shorter than in the DS clips group (P < 0.0001) but did not differ significantly from the Hem-o-lok group (P = 0.199). The time of the operative procedure in the Hem-o-lok group was significantly shorter than in the DS clips group (P = 0.044).

Conclusion

All forms of closure of the appendix base are acceptable, but Hem-o-lok and DS clips have the best potential for further development, and will probably become the method of choice in securing the base of the appendix.
Literature
1.
go back to reference Neugebauer EAM, Troidl H, Kum CK, Eypasch E, Miserez M, Paul A (2006) The EAES clinical practice guidelines on laparoscopic cholecystectomy, appendectomy, and hernia repair. In: Neugebauer EAM, Sauerland S, Fingerhut A, Millat B, Buess G (eds) EAES guidelines for endoscopic surgery. Springer, Berlin, pp 265–289CrossRef Neugebauer EAM, Troidl H, Kum CK, Eypasch E, Miserez M, Paul A (2006) The EAES clinical practice guidelines on laparoscopic cholecystectomy, appendectomy, and hernia repair. In: Neugebauer EAM, Sauerland S, Fingerhut A, Millat B, Buess G (eds) EAES guidelines for endoscopic surgery. Springer, Berlin, pp 265–289CrossRef
2.
go back to reference Wagner M, Aronsky D, Tschudi J, Metzger A, Klaiber C (1996) Laparoscopic stapler appendectomy. A prospective study of 267 consecutive cases. Surg Endosc 10:895–899CrossRefPubMed Wagner M, Aronsky D, Tschudi J, Metzger A, Klaiber C (1996) Laparoscopic stapler appendectomy. A prospective study of 267 consecutive cases. Surg Endosc 10:895–899CrossRefPubMed
3.
go back to reference Hanssen A, Plotnikov S, Dubois R (2007) Laparoscopic appendectomy using a polymeric clip to close the appendicular stump. JSLS 11:59–62PubMedPubMedCentral Hanssen A, Plotnikov S, Dubois R (2007) Laparoscopic appendectomy using a polymeric clip to close the appendicular stump. JSLS 11:59–62PubMedPubMedCentral
4.
go back to reference Delibegovic S, Matovic E (2009) Hem-o-lok plastic clips in securing of the base of the appendix during laparoscopic appendectomy. Surg Endosc 23:2851–2854CrossRefPubMed Delibegovic S, Matovic E (2009) Hem-o-lok plastic clips in securing of the base of the appendix during laparoscopic appendectomy. Surg Endosc 23:2851–2854CrossRefPubMed
5.
go back to reference Delibegovic S (2012) The use of a single Hem-o-lok clip in securing the base of the appendix during laparoscopic appendectomy. J Laparoendosc Adv Surg Tech A 22:86–87CrossRef Delibegovic S (2012) The use of a single Hem-o-lok clip in securing the base of the appendix during laparoscopic appendectomy. J Laparoendosc Adv Surg Tech A 22:86–87CrossRef
6.
go back to reference Delibegović S, Iljazović E, Katica M, Koluh A (2011) Tissue reaction to absorbable endoloop, nonabsorbable titanium staples, and polymer Hem-o-lok clip after laparoscopic appendectomy. JSLS 15:70–76CrossRefPubMedPubMedCentral Delibegović S, Iljazović E, Katica M, Koluh A (2011) Tissue reaction to absorbable endoloop, nonabsorbable titanium staples, and polymer Hem-o-lok clip after laparoscopic appendectomy. JSLS 15:70–76CrossRefPubMedPubMedCentral
7.
go back to reference Rickert A, Krüger CM, Runkel N, Kuthe A, Köninger J, Jansen-Winkeln B, Gutt CN, Marcus DR, Hoey B, Wente MN, Kienle P (2015) The TICAP-Study (titanium clips for appendicular stump closure): a prospective multicentre observational study on appendicular stump closure with an innovative titanium clip. BMC Surg 15:85CrossRefPubMedPubMedCentral Rickert A, Krüger CM, Runkel N, Kuthe A, Köninger J, Jansen-Winkeln B, Gutt CN, Marcus DR, Hoey B, Wente MN, Kienle P (2015) The TICAP-Study (titanium clips for appendicular stump closure): a prospective multicentre observational study on appendicular stump closure with an innovative titanium clip. BMC Surg 15:85CrossRefPubMedPubMedCentral
8.
go back to reference Dai L, Shuai J (2017) Laparoscopic versus open appendectomy in adults and children: a meta-analysis of randomised trials. United Eur Gastroenterol J 4:542–553CrossRef Dai L, Shuai J (2017) Laparoscopic versus open appendectomy in adults and children: a meta-analysis of randomised trials. United Eur Gastroenterol J 4:542–553CrossRef
10.
go back to reference Beldi G, Vorburger SA, Bruegger LE, Kocher T, Inderbitzin D, Candinas D (2006) Analysis of stapling versus endoloops in appendiceal stump closure. Br J Surg 93:1390–1393CrossRefPubMed Beldi G, Vorburger SA, Bruegger LE, Kocher T, Inderbitzin D, Candinas D (2006) Analysis of stapling versus endoloops in appendiceal stump closure. Br J Surg 93:1390–1393CrossRefPubMed
12.
go back to reference Delibegovic S, Mehmedovic Z (2016) The influence of appendiceal base diameter on appendix stump closure in laparoscopic appendectomy. World J Surg 40:2342–2347CrossRefPubMed Delibegovic S, Mehmedovic Z (2016) The influence of appendiceal base diameter on appendix stump closure in laparoscopic appendectomy. World J Surg 40:2342–2347CrossRefPubMed
13.
go back to reference Kwaznenski D, Six C, Stahfeld K (2013) The unacknowledged incidence of laparoscopic stapler malfunction. Surg Endosc 27:86–89CrossRef Kwaznenski D, Six C, Stahfeld K (2013) The unacknowledged incidence of laparoscopic stapler malfunction. Surg Endosc 27:86–89CrossRef
Metadata
Title
The influence of the different forms of appendix base closure on patient outcome in laparoscopic appendectomy: a randomized trial
Authors
Samir Delibegović
Zlatan Mehmedovic
Publication date
01-05-2018
Publisher
Springer US
Published in
Surgical Endoscopy / Issue 5/2018
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-017-5924-z

Other articles of this Issue 5/2018

Surgical Endoscopy 5/2018 Go to the issue