Skip to main content
Top
Published in: Surgical Endoscopy 4/2017

01-04-2017

Technical description of the microinjection pump (MIP®) and granulometric characterization of the aerosol applied for pressurized intraperitoneal aerosol chemotherapy (PIPAC)

Authors: Daniel Göhler, Veria Khosrawipour, Tanja Khosrawipour, David Diaz-Carballo, Thomas Albert Falkenstein, Jürgen Zieren, Michael Stintz, Urs Giger-Pabst

Published in: Surgical Endoscopy | Issue 4/2017

Login to get access

Abstract

Background

Pressurized intraperitoneal aerosol chemotherapy (PIPAC) is gaining acceptance in clinical practice, but detailed information about the microinjection pump (MIP®), the generated aerosol and drug distribution is missing.

Analytical methods

Ex vivo granulometric analyses by means of laser diffraction spectrometry were performed for MIP® aerosol characterization. Beside the standard operation conditions, the impact of the volumetric liquid flow rate on the aerosol characteristics was investigated with different liquids. Granulometric results as well as the local drug distribution were verified by ex vivo gravimetric analyses. On the basis of determined MIP® characteristics, the aerosol droplet size, which is necessary for a homogenous intra-abdominal drug distribution, was calculated.

Results

Granulometric analyses showed that the MIP® aerosol consists of a bimodal volume-weighted particle size distribution (PSD3) with a median droplet diameter of x 50,3 = 25 µm. Calculations reveal that the droplet size for a homogenous intra-abdominal drug distribution during PIPAC therapy should be below 1.2 µm. We show that >97.5 vol% of the aerosolized liquid is delivered as droplets with ≥3 µm in diameter, which are primarily deposited on the surface beneath the MIP® by gravitational settling and inertial impaction. These findings were confirmed by ex vivo gravimetric analyses, where more than 86.0 vol% of the aerosolized liquid was deposited within a circular area with a diameter of 15 cm.

Conclusions

The granulometric aerosol properties, as well as the aerodynamic conditions achieved by standard MIP® operation, do not support the idea of widespread or homogenous drug distribution in the abdominal cavity.
Literature
1.
go back to reference Solass W, Hetzel A, Nadiradze G et al (2012) Description of a novel approach for intraperitoneal drug delivery and the related device. Surg Endosc 26:1849–1855CrossRefPubMed Solass W, Hetzel A, Nadiradze G et al (2012) Description of a novel approach for intraperitoneal drug delivery and the related device. Surg Endosc 26:1849–1855CrossRefPubMed
2.
go back to reference Solass W, Kerb R, Mürdter T et al (2014) Intraperitoneal chemotherapy of peritoneal carcinomatosis using pressurized aerosol as an alternative to liquid solution: first evidence for efficacy. Ann Surg Oncol 21:553–559CrossRefPubMed Solass W, Kerb R, Mürdter T et al (2014) Intraperitoneal chemotherapy of peritoneal carcinomatosis using pressurized aerosol as an alternative to liquid solution: first evidence for efficacy. Ann Surg Oncol 21:553–559CrossRefPubMed
3.
go back to reference Jacquet P, Stuart OA, Chang D et al (1997) Effects of intra-abdominal pressure on pharmacokinetics and tissue distribution of doxorubicin after intraperitoneal administration. Anticancer Drugs 7:596–603CrossRef Jacquet P, Stuart OA, Chang D et al (1997) Effects of intra-abdominal pressure on pharmacokinetics and tissue distribution of doxorubicin after intraperitoneal administration. Anticancer Drugs 7:596–603CrossRef
4.
go back to reference Solass W, Hetzel T, Schwarz T, Nadiradze G, Sagynaliev E, Reymond MA (2014) PIPAC technology. In: Reymond MA, Solass W (eds) Pressurized intraperitoneal aerosol chemotherapy—cancer under pressure, vol Chapter 8, 1st edn. De Gruyter, Berlin, pp 87–94 Solass W, Hetzel T, Schwarz T, Nadiradze G, Sagynaliev E, Reymond MA (2014) PIPAC technology. In: Reymond MA, Solass W (eds) Pressurized intraperitoneal aerosol chemotherapy—cancer under pressure, vol Chapter 8, 1st edn. De Gruyter, Berlin, pp 87–94
5.
go back to reference Khosrawipour V, Khosrawipour T, Diaz-Carballo D, Förster E, Zieren J, Giger-Pabst U (2016) Exploring the spatial drug distribution pattern during pressurized intraperitoneal aerosol chemotherapy (PIPAC). Ann Surg Oncol 23:1220–1224CrossRefPubMed Khosrawipour V, Khosrawipour T, Diaz-Carballo D, Förster E, Zieren J, Giger-Pabst U (2016) Exploring the spatial drug distribution pattern during pressurized intraperitoneal aerosol chemotherapy (PIPAC). Ann Surg Oncol 23:1220–1224CrossRefPubMed
6.
go back to reference Heuer M, Leschonski K (1985) Results obtained with a new instrument for the measurement of particle size distributions from diffraction patterns. Part Part Syst Charact 2:7–13CrossRef Heuer M, Leschonski K (1985) Results obtained with a new instrument for the measurement of particle size distributions from diffraction patterns. Part Part Syst Charact 2:7–13CrossRef
7.
go back to reference ISO 13320:2009. Particle size analysis—laser diffraction ISO 13320:2009. Particle size analysis—laser diffraction
9.
go back to reference ISO 9276-1:1998. Representation of results of particle size analysis—part 1: graphical representation ISO 9276-1:1998. Representation of results of particle size analysis—part 1: graphical representation
10.
go back to reference ISO 26824:2013. Particle characterization of particulate systems—vocabulary ISO 26824:2013. Particle characterization of particulate systems—vocabulary
11.
go back to reference Leschonski K (1984) Representation and evaluation of particle size analysis data. Part Part Syst Charact 1:89–95CrossRef Leschonski K (1984) Representation and evaluation of particle size analysis data. Part Part Syst Charact 1:89–95CrossRef
12.
go back to reference Bowen P (2002) Particle size distribution measurement from millimeters to nanometers and from rods to platelets. J Dispers Sci Technol 23:631–662CrossRef Bowen P (2002) Particle size distribution measurement from millimeters to nanometers and from rods to platelets. J Dispers Sci Technol 23:631–662CrossRef
14.
go back to reference Göhler D, Stintz M (2014) Granulometric characterization of airborne particulate release during spray application of nanoparticle-doped coatings. J Nanopart Res 16:2520CrossRefPubMedPubMedCentral Göhler D, Stintz M (2014) Granulometric characterization of airborne particulate release during spray application of nanoparticle-doped coatings. J Nanopart Res 16:2520CrossRefPubMedPubMedCentral
15.
go back to reference Hinds WC (1999) Aerosol technology—properties, behavior, and measurement of airborne particles. Wiley, New York Hinds WC (1999) Aerosol technology—properties, behavior, and measurement of airborne particles. Wiley, New York
16.
go back to reference Khilnani GC, Banga A (2004) Aerosol therapy. JIACM 5(2):114–123 Khilnani GC, Banga A (2004) Aerosol therapy. JIACM 5(2):114–123
Metadata
Title
Technical description of the microinjection pump (MIP®) and granulometric characterization of the aerosol applied for pressurized intraperitoneal aerosol chemotherapy (PIPAC)
Authors
Daniel Göhler
Veria Khosrawipour
Tanja Khosrawipour
David Diaz-Carballo
Thomas Albert Falkenstein
Jürgen Zieren
Michael Stintz
Urs Giger-Pabst
Publication date
01-04-2017
Publisher
Springer US
Published in
Surgical Endoscopy / Issue 4/2017
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-016-5174-5

Other articles of this Issue 4/2017

Surgical Endoscopy 4/2017 Go to the issue