Skip to main content
Top
Published in: Surgical Endoscopy 4/2017

01-04-2017

Autologous augmentation of hiatal hernia repair with filtered platelet concentrate improves tissue remodeling in a swine model

Authors: Maria S. Altieri, Gabriel Pagnotti, Angelique Corthals, Kenneth Shroyer, Aurora D. Pryor, Mark Talamini, Dana A. Telem

Published in: Surgical Endoscopy | Issue 4/2017

Login to get access

Abstract

Introduction

Autologus augmentation of wound remodeling with platelet concentrate is a burgeoning field with promising results. We hypothesized that the addition of filtered platelet concentrate (fPC) to an acellular biologic graft would improve crural healing and tissue integrity in hiatal hernia repair.

Methods

Sixteen healthy Yorkshire female pigs were divided into three groups: hiatus repair (HR) (n = 7), HR with biologic graft (HRM; n = 8, and HR with biologic graft and fPC (fPC; n = 9). Surgeries were performed by a single surgeon. Animals were euthanized at 8 weeks, and the distal esophagus with hiatus was harvested en-block. Tissue was graded by a histopathologist on collagen deposition, vascularization, and inflammation at the graft–hiatal interface. Tensile strength testing was performed using the Teststar IIs (MTS), coupled with a strain extensometer (Epsilon). Samples of equal dimensions were preloaded to 1 N and deformed at a constant rate of 0.2 mm/s. Statistical analysis was performed via Kruskal–Wallis one-way analysis of variance.

Results

Aspirate analysis revealed a mean platelet count of 3 million platelets/1 mL of aspirate. Animals in the fPC group had significantly increased mean chronic inflammation (3.1 ± 1.1 vs. 1.8 ± 1.6, 1.2 ± 1.2, p = 0.04) compared to HR alone and HR + biologic graft. Vascular deposition did not differ between groups (p = 0.8). A trend toward increased collagen deposition was demonstrated for the fPC group (1.4 ± 1.1 vs. 2.0 ± 0.6 in HR group and 3.0 ± 1.2 in HRM group, p = 0.06). There was a statistically significant increase in tensile strength, yield force, and Young’s modulus in the fPC group compared with HR and HR + biologic mesh (p < 0.01).

Conclusion

A trend toward increased collagen deposition and vascularity of the fPC group was demonstrated. In addition, there was an increase in tensile strength and yield force in the fPC group. Use of autologous fPC appears a safe and promising adjunct to wound remodeling and healing in a swine model.
Literature
1.
go back to reference Diaz S, Brunt LM, Klingensmith ME, Frisella PM, Soper NJ (2003) Laparoscopic paraesophageal hernia repair, a challenging operation: medium-term outcome of 116 patients. J Gastrointest Surg 7(1):59–66CrossRefPubMed Diaz S, Brunt LM, Klingensmith ME, Frisella PM, Soper NJ (2003) Laparoscopic paraesophageal hernia repair, a challenging operation: medium-term outcome of 116 patients. J Gastrointest Surg 7(1):59–66CrossRefPubMed
2.
go back to reference Dallemagne B, Kohnen L, Perretta S, Weerts J, Markiewicz S, Jehaes C (2011) Laparoscopic repair of paraesophageal hernia. long-term follow-up reveals good clinical outcome despite high radiological recurrence rate. Ann Surg 253(2):291–296CrossRefPubMed Dallemagne B, Kohnen L, Perretta S, Weerts J, Markiewicz S, Jehaes C (2011) Laparoscopic repair of paraesophageal hernia. long-term follow-up reveals good clinical outcome despite high radiological recurrence rate. Ann Surg 253(2):291–296CrossRefPubMed
3.
go back to reference Antoniou SA, Antoniou GA, Koch OO, Pointner R, Granderath FA (2012) Lower recurrence rates after mesh-reinforced versus simple hiatal hernia repair: a meta-analysis of randomized trials. Surg Laparosc Endosc Percutan Tech 22(6):498–502CrossRefPubMed Antoniou SA, Antoniou GA, Koch OO, Pointner R, Granderath FA (2012) Lower recurrence rates after mesh-reinforced versus simple hiatal hernia repair: a meta-analysis of randomized trials. Surg Laparosc Endosc Percutan Tech 22(6):498–502CrossRefPubMed
4.
go back to reference Oelschlager BK, Pellegrini CA, Hunter JG et al (2011) Biologic prosthesis to prevent recurrence after laparoscopic paraesophageal hernia repair: long-term follow-up from a multicenter, prospective, randomized trial. J Am Coll Surg 213(4):461–468CrossRefPubMed Oelschlager BK, Pellegrini CA, Hunter JG et al (2011) Biologic prosthesis to prevent recurrence after laparoscopic paraesophageal hernia repair: long-term follow-up from a multicenter, prospective, randomized trial. J Am Coll Surg 213(4):461–468CrossRefPubMed
5.
go back to reference Heffner JJ, Homes JW, Ferrari JP et al (2012) Bone marrow-derived mesenchymal stem cells and platelet-rich plasma on a collagen matrix to improve fascial healing. Hernia 16(6):677–687CrossRefPubMed Heffner JJ, Homes JW, Ferrari JP et al (2012) Bone marrow-derived mesenchymal stem cells and platelet-rich plasma on a collagen matrix to improve fascial healing. Hernia 16(6):677–687CrossRefPubMed
6.
go back to reference Altman AM, Chiu ES, Bai X et al (2008) Human adipose-derived stem cells adhere to acellular matrix. Aesthetic Plast Surg 32(4):698–699CrossRefPubMed Altman AM, Chiu ES, Bai X et al (2008) Human adipose-derived stem cells adhere to acellular matrix. Aesthetic Plast Surg 32(4):698–699CrossRefPubMed
7.
go back to reference Franz MG, Kuhn MA, Nguyen K et al (2001) Transforming growth factor b(2) lowers the incidence of incisional hernias. J Surg Res 97(2):109–116CrossRefPubMed Franz MG, Kuhn MA, Nguyen K et al (2001) Transforming growth factor b(2) lowers the incidence of incisional hernias. J Surg Res 97(2):109–116CrossRefPubMed
8.
go back to reference Dubay DA, Wang X, Kuhn MA, Robson MC, Franz MG (2004) The prevention of incisional hernia formation using a delayedrelease polymer of basic fibroblast growth factor. Ann Surg 240(1):179–186CrossRefPubMedPubMedCentral Dubay DA, Wang X, Kuhn MA, Robson MC, Franz MG (2004) The prevention of incisional hernia formation using a delayedrelease polymer of basic fibroblast growth factor. Ann Surg 240(1):179–186CrossRefPubMedPubMedCentral
9.
go back to reference Brody FJ, Hunt J, Sackier J (1998) Transthoracic induction of a hiatal hernia in domestic swine. Surg Endosc 12(8):1061–1063CrossRefPubMed Brody FJ, Hunt J, Sackier J (1998) Transthoracic induction of a hiatal hernia in domestic swine. Surg Endosc 12(8):1061–1063CrossRefPubMed
10.
go back to reference Van Eps J, Fernandez-Moure J, Cabrera F, et al (2015) Decreased hernia recurrence using autologous platelet-rich plasma (PRP) with Strattice™ mesh in a rodent ventral hernia model. Surg Endosc 30(8):3239–3249 Van Eps J, Fernandez-Moure J, Cabrera F, et al (2015) Decreased hernia recurrence using autologous platelet-rich plasma (PRP) with Strattice™ mesh in a rodent ventral hernia model. Surg Endosc 30(8):3239–3249
11.
go back to reference Cohen J (1988) Statistical power analysis for the behavioral sciences, 2nd edn. Lawrence Earlbaum Associates, Hillsdale Cohen J (1988) Statistical power analysis for the behavioral sciences, 2nd edn. Lawrence Earlbaum Associates, Hillsdale
12.
go back to reference Fernandez-Moure JS, Van Eps JL, Menn ZK et al (2015) Platelet rich plasma enhances tissue incorporation of biologic mesh. J Surg Res 199(2):412–419CrossRefPubMed Fernandez-Moure JS, Van Eps JL, Menn ZK et al (2015) Platelet rich plasma enhances tissue incorporation of biologic mesh. J Surg Res 199(2):412–419CrossRefPubMed
Metadata
Title
Autologous augmentation of hiatal hernia repair with filtered platelet concentrate improves tissue remodeling in a swine model
Authors
Maria S. Altieri
Gabriel Pagnotti
Angelique Corthals
Kenneth Shroyer
Aurora D. Pryor
Mark Talamini
Dana A. Telem
Publication date
01-04-2017
Publisher
Springer US
Published in
Surgical Endoscopy / Issue 4/2017
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-016-5145-x

Other articles of this Issue 4/2017

Surgical Endoscopy 4/2017 Go to the issue