Skip to main content
Top
Published in: Surgical Endoscopy 6/2016

01-06-2016

The relationship between intracranial pressure and obesity: an ultrasonographic evaluation of the optic nerve

Authors: Fernando Dip, David Nguyen, Morris Sasson, Emanuele Lo Menzo, Samuel Szomstein, Raul Rosenthal

Published in: Surgical Endoscopy | Issue 6/2016

Login to get access

Abstract

Background

Measurements of optic nerve sheath diameter (ONSD) with noninvasive ocular ultrasonography have been shown to be accurate in determining increased intracranial pressure. Obesity is associated with chronic increases in intraabdominal pressure that could consequently result in intracranial hypertension. By utilizing ONSD ultrasonographic measurements, we compare the difference that may exist between obese and non-obese patients.

Study Design

We prospectively collected data from patients who underwent laparoscopic procedures in the supine position between July 2013 and March 2014. Ophthalmic pathology was not present in any patient. Ultrasonographic measurement of the ONSD was obtained sagittally with a 12-MHz transducer 3 mm from its origin. The measurements were taken at 0, 15, and 30 min, and at the end of surgery.

Results

There were 62 subjects, 28 females (45.2 %) and 34 males (54.8 %), with a mean age of 44.22 ± 10.44 years (range 23–66). Forty-eight percent of patients were non-obese, and 52 % of patients were obese. The mean body mass index was 30.70 ± 7.61 kg/m2 (range 20.0–59.5). The mean ONSD of non-obese and obese patients was 4.7 and 5.5 mm at baseline (p = 0.01), 5.4 and 6.2 mm at 15 min (p = 0.01), 5.8 and 6.6 mm at 30 min (p = 0.01), and 5.1 and 5.7 mm after deflation of pneumoperitoneum (p = 0.03), respectively.

Conclusions

Utilizing a noninvasive method to measure the ONSD, a chronic increase in intracranial pressure in obese patients was demonstrated. The increase in the ONSD during laparoscopic procedures reflects a temporary increase in the intracranial pressure from baseline.
Literature
2.
go back to reference Wakerley B, Tan M, Ting E (2014) Idiopathic intracranial hypertension. Cephalalgia. 2014 May 20. [Epub ahead of print] Wakerley B, Tan M, Ting E (2014) Idiopathic intracranial hypertension. Cephalalgia. 2014 May 20. [Epub ahead of print]
3.
go back to reference Willenberg T, Clemens R, Haegeli LM, Amann-Vesti B, Baumgartner I, Husmann M (2011) The influence of abdominal pressure on lower extremity venous pressure and hemodynamics: a human in vivo model simulating the effect of abdominal obesity. Eur J Vasc Endovasc Surg 41(6):849–855CrossRefPubMed Willenberg T, Clemens R, Haegeli LM, Amann-Vesti B, Baumgartner I, Husmann M (2011) The influence of abdominal pressure on lower extremity venous pressure and hemodynamics: a human in vivo model simulating the effect of abdominal obesity. Eur J Vasc Endovasc Surg 41(6):849–855CrossRefPubMed
4.
go back to reference Varela JE, Hinojosa M, Nguyen N (2009) Correlations between intra-abdominal pressure and obesity-related co-morbidities. Surg Obes Relat Dis 5(5):524–528CrossRefPubMed Varela JE, Hinojosa M, Nguyen N (2009) Correlations between intra-abdominal pressure and obesity-related co-morbidities. Surg Obes Relat Dis 5(5):524–528CrossRefPubMed
5.
go back to reference Sugerman HJ (2001) Effects of increased intra-abdominal pressure in severe obesity. Surg Clin North Am 81(5):1063–1075CrossRefPubMed Sugerman HJ (2001) Effects of increased intra-abdominal pressure in severe obesity. Surg Clin North Am 81(5):1063–1075CrossRefPubMed
6.
go back to reference Rosenthal RJ, Friedman RL, Kahn AM, Martz J, Thiagarajah S, Cohen D, Shi Q, Nussbaum M (1998) Reasons for intracranial hypertension and hemodynamic instability during acute elevations of intra-abdominal pressure: observations in a large animal model. J Gastrointest Surg 2(5):415–425CrossRefPubMed Rosenthal RJ, Friedman RL, Kahn AM, Martz J, Thiagarajah S, Cohen D, Shi Q, Nussbaum M (1998) Reasons for intracranial hypertension and hemodynamic instability during acute elevations of intra-abdominal pressure: observations in a large animal model. J Gastrointest Surg 2(5):415–425CrossRefPubMed
7.
go back to reference Rosin D, Brasesco O, Varela J, Saber AA, You S, Rosenthal RJ, Cohn SM (2002) Low-pressure laparoscopy may ameliorate intracranial hypertension and renal hypoperfusion. J Laparoendosc Adv Surg Tech A 12(1):15–19CrossRefPubMed Rosin D, Brasesco O, Varela J, Saber AA, You S, Rosenthal RJ, Cohn SM (2002) Low-pressure laparoscopy may ameliorate intracranial hypertension and renal hypoperfusion. J Laparoendosc Adv Surg Tech A 12(1):15–19CrossRefPubMed
8.
go back to reference Kimberly HH, Shah S, Marill K (2008) Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure. Acad Emerg Med 15:201–204CrossRefPubMed Kimberly HH, Shah S, Marill K (2008) Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure. Acad Emerg Med 15:201–204CrossRefPubMed
9.
go back to reference Geeraerts T, Merceron S, Benhamou D, Vigué B, Duranteau J (2008) Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients. Intensive Care Med 34:2062–2067CrossRefPubMed Geeraerts T, Merceron S, Benhamou D, Vigué B, Duranteau J (2008) Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients. Intensive Care Med 34:2062–2067CrossRefPubMed
10.
go back to reference Moretti R, Pizzi B, Cassini F, Vivaldi N (2009) Reliability of optic nerve ultrasound for the evaluation of patients with spontaneous intracranial hemorrhage. Neurocrit Care 11:406–410CrossRefPubMed Moretti R, Pizzi B, Cassini F, Vivaldi N (2009) Reliability of optic nerve ultrasound for the evaluation of patients with spontaneous intracranial hemorrhage. Neurocrit Care 11:406–410CrossRefPubMed
11.
go back to reference Rajajee V, Vanaman M, Fletcher JJ, Jacobs TL (2011) Optic nerve ultrasound for the detection of raised intracranial pressure. Neurocrit Care 15(3):506–515CrossRefPubMed Rajajee V, Vanaman M, Fletcher JJ, Jacobs TL (2011) Optic nerve ultrasound for the detection of raised intracranial pressure. Neurocrit Care 15(3):506–515CrossRefPubMed
12.
13.
go back to reference Lambert DM, Marceau S, Forse RA (2005) Intra-abdominal pressure in the morbidly obese. Obes Surg 15(9):1225–1232CrossRefPubMed Lambert DM, Marceau S, Forse RA (2005) Intra-abdominal pressure in the morbidly obese. Obes Surg 15(9):1225–1232CrossRefPubMed
14.
go back to reference Noblett KL, Jensen JK, Ostergard DR (1997) The relationship of body mass index to intra-abdominal pressure as measured by multichannel cystometry. Int Urogynecol J Pelvic Floor Dysfunct 8(6):323–326CrossRefPubMed Noblett KL, Jensen JK, Ostergard DR (1997) The relationship of body mass index to intra-abdominal pressure as measured by multichannel cystometry. Int Urogynecol J Pelvic Floor Dysfunct 8(6):323–326CrossRefPubMed
15.
go back to reference Schein M, Wittmann DH, Aprahamian CC, Condon RE (1995) The abdominal compartment syndrome: the physiological and clinical consequences of elevated intra-abdominal pressure. J Am Coll Surg 180:745–753PubMed Schein M, Wittmann DH, Aprahamian CC, Condon RE (1995) The abdominal compartment syndrome: the physiological and clinical consequences of elevated intra-abdominal pressure. J Am Coll Surg 180:745–753PubMed
16.
go back to reference Cullen DJ, Coyle JP, Teplick R, Long MC (1989) Cardiovascular, pulmonary, and renal effects of massively increased intra-abdominal pressure in critically ill patients. Crit Care 17:118–121CrossRef Cullen DJ, Coyle JP, Teplick R, Long MC (1989) Cardiovascular, pulmonary, and renal effects of massively increased intra-abdominal pressure in critically ill patients. Crit Care 17:118–121CrossRef
17.
go back to reference Sugerman HJ, Wolfe LG, Sica DA, Clore JN (2003) Diabetes and hypertension in severe obesity and effects of gastric bypass-induced weight loss. Ann Surg 237:751–756PubMedPubMedCentral Sugerman HJ, Wolfe LG, Sica DA, Clore JN (2003) Diabetes and hypertension in severe obesity and effects of gastric bypass-induced weight loss. Ann Surg 237:751–756PubMedPubMedCentral
18.
go back to reference Sugerman H, Windsor A, Bessos M, Kellum J, Reines H, DeMaria E (1998) Effects of surgically induced weight loss on urinary bladder pressure, sagittal abdominal diameter and obesity co-morbidity. Int J Obes Relat Metab Disord 22:230–235CrossRefPubMed Sugerman H, Windsor A, Bessos M, Kellum J, Reines H, DeMaria E (1998) Effects of surgically induced weight loss on urinary bladder pressure, sagittal abdominal diameter and obesity co-morbidity. Int J Obes Relat Metab Disord 22:230–235CrossRefPubMed
19.
go back to reference Sugerman H, Windsor A, Bessos M, Wolfe L (1997) Intra-abdominal pressure, sagittal abdominal diameter and obesity comorbidity. J Intern Med 241:71–79CrossRefPubMed Sugerman H, Windsor A, Bessos M, Wolfe L (1997) Intra-abdominal pressure, sagittal abdominal diameter and obesity comorbidity. J Intern Med 241:71–79CrossRefPubMed
20.
go back to reference Dip F, Nguyen D, Lo Menzo E, Szomstein S, Rosenthal R (2014) Non-invasive intracranial pressure methods during pneumoperitoneum in an animal model. J Am Coll Surg 219(3):S1–S162CrossRef Dip F, Nguyen D, Lo Menzo E, Szomstein S, Rosenthal R (2014) Non-invasive intracranial pressure methods during pneumoperitoneum in an animal model. J Am Coll Surg 219(3):S1–S162CrossRef
21.
go back to reference Whiteley JR, Taylor J, Henry M, Epperson TI, Hand WR (2014) Detection of elevated intracranial pressure in robot-assisted laparoscopic radical prostatectomy using ultrasonography of optic nerve sheath diameter. J Neurosurg Anesthesiol 27(2):155–159 CrossRef Whiteley JR, Taylor J, Henry M, Epperson TI, Hand WR (2014) Detection of elevated intracranial pressure in robot-assisted laparoscopic radical prostatectomy using ultrasonography of optic nerve sheath diameter. J Neurosurg Anesthesiol 27(2):155–159 CrossRef
22.
go back to reference Frumin E, Schlang J, Wiechmann W, Hata S, Rosen S, Anderson C, Pare L, Rosen M, Fox JC (2014) Prospective analysis of single operator sonographic optic nerve sheath diameter measurement for diagnosis of elevated intracranial pressure. West J Emerg Med 15(2):217–220CrossRefPubMedPubMedCentral Frumin E, Schlang J, Wiechmann W, Hata S, Rosen S, Anderson C, Pare L, Rosen M, Fox JC (2014) Prospective analysis of single operator sonographic optic nerve sheath diameter measurement for diagnosis of elevated intracranial pressure. West J Emerg Med 15(2):217–220CrossRefPubMedPubMedCentral
23.
go back to reference Brainar L, Chen DA, Aziz KM, Hillman TA (2012) Association of benign intracranial hypertension and spontaneous encephalocele with cerebrospinal fluid leak. Otol Neurotol 33(9):1621–1624CrossRef Brainar L, Chen DA, Aziz KM, Hillman TA (2012) Association of benign intracranial hypertension and spontaneous encephalocele with cerebrospinal fluid leak. Otol Neurotol 33(9):1621–1624CrossRef
24.
go back to reference Kim MS, Bai SJ, Lee JR, Choi YD, Kim YJ, Choi SH (2014) Increase in intracranial pressure during carbon dioxide pneumoperitoneum with steep trendelenburg positioning proven by ultrasonographic measurement of optic nerve sheath diameter. J Endourol 28(7):801–806CrossRefPubMed Kim MS, Bai SJ, Lee JR, Choi YD, Kim YJ, Choi SH (2014) Increase in intracranial pressure during carbon dioxide pneumoperitoneum with steep trendelenburg positioning proven by ultrasonographic measurement of optic nerve sheath diameter. J Endourol 28(7):801–806CrossRefPubMed
25.
go back to reference Ballantyne SA, O’Neill G, Hamilton R, Hollman AS (2002) Observer variation in the sonographic measurement of optic nerve sheath diameter in normal adults. Eur J Ultrasound 15:145–149CrossRefPubMed Ballantyne SA, O’Neill G, Hamilton R, Hollman AS (2002) Observer variation in the sonographic measurement of optic nerve sheath diameter in normal adults. Eur J Ultrasound 15:145–149CrossRefPubMed
26.
go back to reference Bäuerle J, Schuchardt F, Schroeder L, Egger K, Weigel M, Harloff A (2013) Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging. BMC Neurol 1(13):187CrossRef Bäuerle J, Schuchardt F, Schroeder L, Egger K, Weigel M, Harloff A (2013) Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging. BMC Neurol 1(13):187CrossRef
Metadata
Title
The relationship between intracranial pressure and obesity: an ultrasonographic evaluation of the optic nerve
Authors
Fernando Dip
David Nguyen
Morris Sasson
Emanuele Lo Menzo
Samuel Szomstein
Raul Rosenthal
Publication date
01-06-2016
Publisher
Springer US
Published in
Surgical Endoscopy / Issue 6/2016
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-015-4458-5

Other articles of this Issue 6/2016

Surgical Endoscopy 6/2016 Go to the issue