Skip to main content
Top
Published in: Surgical Endoscopy 11/2013

01-11-2013 | Dynamic Manuscript

Suction test to demonstrate the peritoneal edge during laparoscopic extraperitoneal inguinal hernia repair

Authors: Christopher Nahm, Jason Free, Sivakumar Gananadha, Thomas J. Hugh, Jaswinder S. Samra

Published in: Surgical Endoscopy | Issue 11/2013

Login to get access

Abstract

Introduction

Inadequate peritoneal dissection from retroperitoneal structures may account for a large number of hernia recurrences amongst surgeons and trainees who are new to totally extraperitoneal (TEP) laparoscopic inguinal hernia repair. In this paper, we describe a simple dynamic test that allows surgeons to better appreciate the peritoneal edge during the initial dissection phase of TEP inguinal hernia repair, allowing for more adequate dissection of the peritoneum from retroperitoneal structures before placement of mesh.

Methods

Data from a single surgeon was collected on 113 consecutive patients who underwent laparoscopic TEP inguinal hernia repair at the Royal North Shore Hospital in Sydney. The data was retrospectively reviewed to determine the number of cases in which the suction test led to further peritoneal dissection prior to mesh placement.

Operative Technique

After balloon dissection of the pre-peritoneal space and initial dissection of peritoneum and sac from retroperitoneal structures, a laparoscopic suction device is used to aspirate the insufflated gas from the pre-peritoneal space to cause the peritoneum to bulge anteriorly, thus demonstrating the edge of the peritoneal reflection. Further dissection is performed if deemed necessary at this point, and the mesh is placed over the hernia defect.

Results

136 TEP hernia repairs were performed in 113 patients. In 26 (23 %) of patients, the abovementioned technique was of particular value resulting in further dissection of peritoneum prior to mesh placement. There were no complications as a direct result of the test.

Conclusion

This dynamic suction test is a risk-free and useful operative tool for surgeons and trainees who are new to TEP inguinal hernia repair, and provides a definitive way of identifying the peritoneal reflection to ensure the peritoneum has been dissected adequately prior to mesh placement.
Appendix
Available only for authorised users
Literature
1.
go back to reference McKernan JB, Laws HL (1993) Laparoscopic repair of inguinal hernias using a totally extraperitoneal prosthetic approach. Surg Endosc 7(1):26–28PubMedCrossRef McKernan JB, Laws HL (1993) Laparoscopic repair of inguinal hernias using a totally extraperitoneal prosthetic approach. Surg Endosc 7(1):26–28PubMedCrossRef
2.
go back to reference Langeveld HR, van’t Riet M, Weidema WF, Stassen LP, Steyerberg EW, Lange J, Bonjer HJ, Jeekel J (2010) Total extraperitoneal inguinal hernia repair compared with lichtenstein (the LEVEL-Trial). Ann Surg 251(5):819–824 Langeveld HR, van’t Riet M, Weidema WF, Stassen LP, Steyerberg EW, Lange J, Bonjer HJ, Jeekel J (2010) Total extraperitoneal inguinal hernia repair compared with lichtenstein (the LEVEL-Trial). Ann Surg 251(5):819–824
3.
go back to reference Eker HH, Langeveld HR, Klitsie PJ, van't Riet M, Stassen LP, Weidema WF, Steyerberg EW, Lange JF, Bonjer HJ, Jeekel J (2012) Randomized clinical trial of total extraperitoneal inguinal hernioplasty vs Lichtenstein repair: a long-term follow-up study. Arch Surg 147(3):256–260 Eker HH, Langeveld HR, Klitsie PJ, van't Riet M, Stassen LP, Weidema WF, Steyerberg EW, Lange JF, Bonjer HJ, Jeekel J (2012) Randomized clinical trial of total extraperitoneal inguinal hernioplasty vs Lichtenstein repair: a long-term follow-up study. Arch Surg 147(3):256–260
4.
go back to reference Eklund A, Montgomery A, Bergkvist L, Rudberg C (2010) Chronic pain 5 years after randomized comparison of laparoscopic and Lichtenstein inguinal hernia repair. Br J Surg 97(4):600–608PubMedCrossRef Eklund A, Montgomery A, Bergkvist L, Rudberg C (2010) Chronic pain 5 years after randomized comparison of laparoscopic and Lichtenstein inguinal hernia repair. Br J Surg 97(4):600–608PubMedCrossRef
5.
go back to reference Neumayer L, Giobbie-Hurder A, Jonasson O, Fitzgibbons R Jr, Dunlop D, Gibbs J, Reda D, Henderson W, Veterans Affairs Cooperative Studies Program 456 Investigators (2004) Open mesh versus laparoscopic mesh repair of inguinal hernia. N Engl J Med 350(18):1819–1827 Neumayer L, Giobbie-Hurder A, Jonasson O, Fitzgibbons R Jr, Dunlop D, Gibbs J, Reda D, Henderson W, Veterans Affairs Cooperative Studies Program 456 Investigators (2004) Open mesh versus laparoscopic mesh repair of inguinal hernia. N Engl J Med 350(18):1819–1827
6.
go back to reference O’Reilly EA, Burke JP, O’Connell PR (2012) A meta-analysis of surgical morbidity and recurrence after laparoscopic and open repair of primary unilateral inguinal hernia. Ann Surg 255(5):846–853PubMedCrossRef O’Reilly EA, Burke JP, O’Connell PR (2012) A meta-analysis of surgical morbidity and recurrence after laparoscopic and open repair of primary unilateral inguinal hernia. Ann Surg 255(5):846–853PubMedCrossRef
7.
go back to reference McCormack K, Wake B, Perez J, Fraser C, Cook J, McIntosh E, Vale L, Grant A (2005) Laparoscopic surgery for inguinal hernia repair: systematic review of effectiveness and economic evaluation. Health Technol Assess 9(14):1–203, iii–iv McCormack K, Wake B, Perez J, Fraser C, Cook J, McIntosh E, Vale L, Grant A (2005) Laparoscopic surgery for inguinal hernia repair: systematic review of effectiveness and economic evaluation. Health Technol Assess 9(14):1–203, iii–iv
8.
go back to reference Lau H, Lee F (2002) A prospective comparative study of needlescopic and conventional endoscopic extraperitoneal inguinal hernioplasty. Surg Endosc 16(12):1737–1740PubMedCrossRef Lau H, Lee F (2002) A prospective comparative study of needlescopic and conventional endoscopic extraperitoneal inguinal hernioplasty. Surg Endosc 16(12):1737–1740PubMedCrossRef
9.
go back to reference Bittner R, Arregui ME, Bisgaard T, Dudai M, Ferzli GS, Fitzgibbons RJ, Fortelny RH, Klinge U, Kockerling F, Kuhry E, Kukleta J, Lomanto D, Misra MC, Montgomery A, Morales-Conde S, Reinpold W, Rosenberg J, Sauerland S, Schug-Pass C, Singh K, Timoney M, Weyhe D, Chowbey P (2011) Guidelines for laparoscopic (TAPP) and endoscopic (TEP) treatment of inguinal Hernia [International Endohernia Society (IEHS)]. Surg Endosc 25(9):2773–2843 Bittner R, Arregui ME, Bisgaard T, Dudai M, Ferzli GS, Fitzgibbons RJ, Fortelny RH, Klinge U, Kockerling F, Kuhry E, Kukleta J, Lomanto D, Misra MC, Montgomery A, Morales-Conde S, Reinpold W, Rosenberg J, Sauerland S, Schug-Pass C, Singh K, Timoney M, Weyhe D, Chowbey P (2011) Guidelines for laparoscopic (TAPP) and endoscopic (TEP) treatment of inguinal Hernia [International Endohernia Society (IEHS)]. Surg Endosc 25(9):2773–2843
10.
go back to reference Bringman S, Ek A, Haglind E, Heikkinen T, Kald A, Kylberg F, Ramel S, Wallon C, Anderberg B (2001) Is a dissection balloon beneficial in totally extraperitoneal endoscopic hernioplasty (TEP)? A randomized prospective multicenter study. Surg Endosc 15(3):266–270 Bringman S, Ek A, Haglind E, Heikkinen T, Kald A, Kylberg F, Ramel S, Wallon C, Anderberg B (2001) Is a dissection balloon beneficial in totally extraperitoneal endoscopic hernioplasty (TEP)? A randomized prospective multicenter study. Surg Endosc 15(3):266–270
11.
go back to reference Bell RCW, Price JG (2003) Laparoscopic inguinal hernia repair using an anatomically contoured three-dimensional mesh. Surg Endosc 17(11):1784–1788PubMedCrossRef Bell RCW, Price JG (2003) Laparoscopic inguinal hernia repair using an anatomically contoured three-dimensional mesh. Surg Endosc 17(11):1784–1788PubMedCrossRef
12.
go back to reference Akolekar D, Kumar S, Khan LR, de Beaux AC, Nixon SJ (2008) Comparison of recurrence with lightweight composite polypropylene mesh and heavyweight mesh in laparoscopic totally extraperitoneal inguinal hernia repair: an audit of 1,232 repairs. Hernia 12(1):39–43PubMedCrossRef Akolekar D, Kumar S, Khan LR, de Beaux AC, Nixon SJ (2008) Comparison of recurrence with lightweight composite polypropylene mesh and heavyweight mesh in laparoscopic totally extraperitoneal inguinal hernia repair: an audit of 1,232 repairs. Hernia 12(1):39–43PubMedCrossRef
13.
go back to reference Berney CR (2012) The Endoloop technique for the primary closure of direct inguinal hernia defect during the endoscopic totally extraperitoneal approach. Hernia 16(3):301–305PubMedCrossRef Berney CR (2012) The Endoloop technique for the primary closure of direct inguinal hernia defect during the endoscopic totally extraperitoneal approach. Hernia 16(3):301–305PubMedCrossRef
14.
go back to reference Olmi S, Scaini A, Erba L, Croce E (2007) Use of fibrin glue (Tissucol) in laparoscopic repair of abdominal wall defects: preliminary experience. Surg Endosc 21(3):409–413PubMedCrossRef Olmi S, Scaini A, Erba L, Croce E (2007) Use of fibrin glue (Tissucol) in laparoscopic repair of abdominal wall defects: preliminary experience. Surg Endosc 21(3):409–413PubMedCrossRef
15.
go back to reference Taylor C, Layani L, Liew V, Ghusn M, Crampton N, White S (2008) Laparoscopic inguinal hernia repair without mesh fixation, early results of a large randomised clinical trial. Surg Endosc 22(3):757–762PubMedCrossRef Taylor C, Layani L, Liew V, Ghusn M, Crampton N, White S (2008) Laparoscopic inguinal hernia repair without mesh fixation, early results of a large randomised clinical trial. Surg Endosc 22(3):757–762PubMedCrossRef
Metadata
Title
Suction test to demonstrate the peritoneal edge during laparoscopic extraperitoneal inguinal hernia repair
Authors
Christopher Nahm
Jason Free
Sivakumar Gananadha
Thomas J. Hugh
Jaswinder S. Samra
Publication date
01-11-2013
Publisher
Springer US
Published in
Surgical Endoscopy / Issue 11/2013
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-013-3031-3

Other articles of this Issue 11/2013

Surgical Endoscopy 11/2013 Go to the issue