Skip to main content
Top
Published in: Surgical Endoscopy 5/2013

01-05-2013

Influence of carbon dioxide insufflation of the neck on intraocular pressure during robot-assisted endoscopic thyroidectomy: a comparison with open thyroidectomy

Authors: Jie-Ae Kim, Jee-Soo Kim, Moon-Seok Chang, Yeon-Kyeong Yoo, Duk-Kyung Kim

Published in: Surgical Endoscopy | Issue 5/2013

Login to get access

Abstract

Background

Increased intraocular pressure (IOP) during surgery can result in serious ophthalmic complications. We hypothesized that carbon dioxide (CO2) insufflation of the neck during endoscopic thyroidectomy would constrict the jugular veins mechanically, causing elevated venous pressure and thus elevated IOP. We compared IOP changes at each step of open thyroidectomy (OT) versus robot-assisted endoscopic thyroidectomy (RET)

Methods

Perioperatively, IOP was measured at six time points in patients undergoing OT (n = 18) or RET with CO2 insufflation (n = 19). Anesthesia, ventilatory strategy, intravenous infusions, and surgical positioning were standardized

Results

In both groups, induction of anesthesia reduced IOP, but surgical positioning with the neck in extension had no effect on IOP. In the OT group, IOP remained unchanged during anesthesia. In the RET group, CO2 insufflation significantly increased IOP to an average of 3.6 ± 3.0 mmHg higher than the previous measurement (P < 0.001), and this IOP increase persisted immediately before gas deflation. These elevated IOP values during CO2 insufflation in the RET group were significantly higher than those at corresponding time points in the OT group. However, these elevated IOP values were similar to the pre-anesthetic baseline IOP

Conclusion

CO2 insufflation of the neck at pressure of 6 mmHg increased the IOP significantly compared with open thyroidectomy. However, this increase in IOP could be balanced by an anesthetic-induced IOP-lowering effect, thereby having no clinical significance in patients with normal IOP undergoing robot-assisted endoscopic thyroidectomy.
Literature
1.
go back to reference Roth S (2009) Perioperative visual loss: what do we know, what can we do? Br J Anaesth 103(Suppl 1):31–40CrossRef Roth S (2009) Perioperative visual loss: what do we know, what can we do? Br J Anaesth 103(Suppl 1):31–40CrossRef
2.
go back to reference Warner ME, Warner MA, Garrity JA, MacKenzie RA, Warner DO (2001) The frequency of perioperative vision loss. Anesth Analg 93:1417–1421PubMedCrossRef Warner ME, Warner MA, Garrity JA, MacKenzie RA, Warner DO (2001) The frequency of perioperative vision loss. Anesth Analg 93:1417–1421PubMedCrossRef
3.
go back to reference Götte K, Riedel F, Knorz MC, Hörmann K (2000) Delayed anterior ischemic optic neuropathy after neck dissection. Arch Otolaryngol Head Neck Surg 126:220–223PubMed Götte K, Riedel F, Knorz MC, Hörmann K (2000) Delayed anterior ischemic optic neuropathy after neck dissection. Arch Otolaryngol Head Neck Surg 126:220–223PubMed
4.
go back to reference Buono LM, Foroozan R (2005) Perioperative posterior ischemic optic neuropathy: review of the literature. Surv Ophthalmol 50:15–26PubMedCrossRef Buono LM, Foroozan R (2005) Perioperative posterior ischemic optic neuropathy: review of the literature. Surv Ophthalmol 50:15–26PubMedCrossRef
5.
go back to reference Murphy DF (1985) Anesthesia and intraocular pressure. Anesth Analg 64:520–530PubMed Murphy DF (1985) Anesthesia and intraocular pressure. Anesth Analg 64:520–530PubMed
6.
go back to reference Rubino F, Pamoukian VN, Zhu JF, Deutsch H, Inabnet WB, Gagner M (2000) Endoscopic endocrine neck surgery with carbon dioxide insufflation: the effect on intracranial pressure in a large animal model. Surgery 128:1035–1042PubMedCrossRef Rubino F, Pamoukian VN, Zhu JF, Deutsch H, Inabnet WB, Gagner M (2000) Endoscopic endocrine neck surgery with carbon dioxide insufflation: the effect on intracranial pressure in a large animal model. Surgery 128:1035–1042PubMedCrossRef
7.
go back to reference Lee KE, Choi JY, Youn YK (2011) Bilateral axillo-breast approach robotic thyroidectomy. Surg Laparosc Endosc Percutan Tech 21:230–236PubMedCrossRef Lee KE, Choi JY, Youn YK (2011) Bilateral axillo-breast approach robotic thyroidectomy. Surg Laparosc Endosc Percutan Tech 21:230–236PubMedCrossRef
8.
go back to reference Lee J, Lee JH, Nah KY, Soh EY, Chung WY (2011) Comparison of endoscopic and robotic thyroidectomy. Ann Surg Oncol 18:1439–1446PubMedCrossRef Lee J, Lee JH, Nah KY, Soh EY, Chung WY (2011) Comparison of endoscopic and robotic thyroidectomy. Ann Surg Oncol 18:1439–1446PubMedCrossRef
9.
go back to reference Lee S, Ryu HR, Park JH, Kim KH, Kang SW, Jeong JJ, Nam KH, Chung WY, Park CS (2011) Excellence in robotic thyroid surgery: a comparative study of robot-assisted versus conventional endoscopic thyroidectomy in papillary thyroid microcarcinoma patients. Ann Surg 253:1060–1066PubMedCrossRef Lee S, Ryu HR, Park JH, Kim KH, Kang SW, Jeong JJ, Nam KH, Chung WY, Park CS (2011) Excellence in robotic thyroid surgery: a comparative study of robot-assisted versus conventional endoscopic thyroidectomy in papillary thyroid microcarcinoma patients. Ann Surg 253:1060–1066PubMedCrossRef
10.
go back to reference Hay ID, Bergstrahl EJ, Goellner JR, Ebersold JR, Grant CS (1993) Predicting outcome in papillary thyroid carcinoma: development of a reliable prognostic scoring system in a cohort of 1779 patients surgically treated at one institution during 1940 through 1989. Surgery 114:1050–1058PubMed Hay ID, Bergstrahl EJ, Goellner JR, Ebersold JR, Grant CS (1993) Predicting outcome in papillary thyroid carcinoma: development of a reliable prognostic scoring system in a cohort of 1779 patients surgically treated at one institution during 1940 through 1989. Surgery 114:1050–1058PubMed
11.
go back to reference Ochiai R, Takeda J, Noguchi J, Ohgami M, Ishii S (2000) Subcutaneous carbon dioxide insufflation does not cause hypercarbia during endoscopic thyroidectomy. Anesth Analg 90:760–762PubMedCrossRef Ochiai R, Takeda J, Noguchi J, Ohgami M, Ishii S (2000) Subcutaneous carbon dioxide insufflation does not cause hypercarbia during endoscopic thyroidectomy. Anesth Analg 90:760–762PubMedCrossRef
12.
go back to reference Shimizu K (2001) Minimally invasive thyroid surgery. Best Pract Res Clin Endocrinol Metab 15:123–137PubMedCrossRef Shimizu K (2001) Minimally invasive thyroid surgery. Best Pract Res Clin Endocrinol Metab 15:123–137PubMedCrossRef
13.
go back to reference Teng C, Gurses-Ozden R, Liebmann JM, Tello C, Ritch R (2003) Effect of a tight necktie on intraocular pressure. Br J Ophthalmol 87:946–948PubMedCrossRef Teng C, Gurses-Ozden R, Liebmann JM, Tello C, Ritch R (2003) Effect of a tight necktie on intraocular pressure. Br J Ophthalmol 87:946–948PubMedCrossRef
14.
go back to reference Malihi M, Sit AJ (2012) Effect of head and body position on intraocular pressure. Ophthalmology 119:987–991PubMedCrossRef Malihi M, Sit AJ (2012) Effect of head and body position on intraocular pressure. Ophthalmology 119:987–991PubMedCrossRef
15.
go back to reference Klein A, Shemesh G, Loewenstein A, Kurtz S (2011) Intraocular pressure measurements in relation to head position and through soft contact lenses: comparison of three portable instruments. Ophthalmic Surg Lasers Imaging 42:64–71PubMedCrossRef Klein A, Shemesh G, Loewenstein A, Kurtz S (2011) Intraocular pressure measurements in relation to head position and through soft contact lenses: comparison of three portable instruments. Ophthalmic Surg Lasers Imaging 42:64–71PubMedCrossRef
16.
go back to reference Reddy SC, Mohan SM (2010) Intraocular pressure as indicator of sympathetic asymmetry in the eyes. Int J Ophthalmol 3:326–327PubMed Reddy SC, Mohan SM (2010) Intraocular pressure as indicator of sympathetic asymmetry in the eyes. Int J Ophthalmol 3:326–327PubMed
17.
go back to reference Dane S, Gümustekin K, Yazici AT, Baykal O (2003) Correlation between hand preference and intraocular pressure from right and left eyes in right-and left-handers. Vision Res 43:405–408PubMedCrossRef Dane S, Gümustekin K, Yazici AT, Baykal O (2003) Correlation between hand preference and intraocular pressure from right and left eyes in right-and left-handers. Vision Res 43:405–408PubMedCrossRef
18.
go back to reference Awad H, Santilli S, Ohr M, Roth A, Yan W, Fernandez S, Roth S, Patel V (2009) The effects of steep trendelenburg positioning on intraocular pressure during robotic radical prostatectomy. Anesth Analg 109:473–478PubMedCrossRef Awad H, Santilli S, Ohr M, Roth A, Yan W, Fernandez S, Roth S, Patel V (2009) The effects of steep trendelenburg positioning on intraocular pressure during robotic radical prostatectomy. Anesth Analg 109:473–478PubMedCrossRef
19.
go back to reference Madan R, Tamilselvan P, Sadhasivam S, Shende D, Gupta V, Kaul HL (2000) Intra-ocular pressure and haemodynamic changes after tracheal intubation and extubation: a comparative study in glaucomatous and nonglaucomatous children. Anaesthesia 55:380–384PubMedCrossRef Madan R, Tamilselvan P, Sadhasivam S, Shende D, Gupta V, Kaul HL (2000) Intra-ocular pressure and haemodynamic changes after tracheal intubation and extubation: a comparative study in glaucomatous and nonglaucomatous children. Anaesthesia 55:380–384PubMedCrossRef
20.
go back to reference Krieglstein G, Langham ME (1975) Influence of body position on the intraocular pressure of normal and glaucomatous eyes. Ophthalmologica 171:132–145PubMedCrossRef Krieglstein G, Langham ME (1975) Influence of body position on the intraocular pressure of normal and glaucomatous eyes. Ophthalmologica 171:132–145PubMedCrossRef
21.
go back to reference Galambos P, Vafiadis J, Vilchez SE, Wagenfeld L, Matthiessen ET, Richard G, Klemm M, Zeitz O (2006) Compromised autoregulatory control of ocular hemodynamics in glaucoma patients after postural change. Ophthalmology 113:1832–1836PubMedCrossRef Galambos P, Vafiadis J, Vilchez SE, Wagenfeld L, Matthiessen ET, Richard G, Klemm M, Zeitz O (2006) Compromised autoregulatory control of ocular hemodynamics in glaucoma patients after postural change. Ophthalmology 113:1832–1836PubMedCrossRef
Metadata
Title
Influence of carbon dioxide insufflation of the neck on intraocular pressure during robot-assisted endoscopic thyroidectomy: a comparison with open thyroidectomy
Authors
Jie-Ae Kim
Jee-Soo Kim
Moon-Seok Chang
Yeon-Kyeong Yoo
Duk-Kyung Kim
Publication date
01-05-2013
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 5/2013
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-012-2633-5

Other articles of this Issue 5/2013

Surgical Endoscopy 5/2013 Go to the issue