Skip to main content
Top
Published in: Surgical Endoscopy 5/2012

01-05-2012

3D HD versus 2D HD: surgical task efficiency in standardised phantom tasks

Authors: Pirmin Storz, Gerhard F. Buess, Wolfgang Kunert, Andreas Kirschniak

Published in: Surgical Endoscopy | Issue 5/2012

Login to get access

Abstract

Background

Common video systems for laparoscopy provide the surgeon a two-dimensional image (2D), where information on spatial depth can be derived only from secondary spatial depth cues and experience. Although the advantage of stereoscopy for surgical task efficiency has been clearly shown, several attempts to introduce three-dimensional (3D) video systems into clinical routine have failed. The aim of this study is to evaluate users’ performances in standardised surgical phantom model tasks using 3D HD visualisation compared with 2D HD regarding precision and working speed.

Methods

This comparative study uses a 3D HD video system consisting of a dual-channel laparoscope, a stereoscopic camera, a camera controller with two separate outputs and a wavelength multiplex stereoscopic monitor. Each of 20 medical students and 10 laparoscopically experienced surgeons (more than 100 laparoscopic cholecystectomies each) pre-selected in a stereo vision test were asked to perform one task to familiarise themselves with the system and subsequently a set of five standardised tasks encountered in typical surgical procedures. The tasks were performed under either 3D or 2D conditions at random choice and subsequently repeated under the other vision condition. Predefined errors were counted, and time needed was measured.

Results

In four of the five tasks the study participants made fewer mistakes in 3D than in 2D vision. In four of the tasks they needed significantly more time in the 2D mode. Both the student group and the surgeon group showed similarly improved performance, while the surgeon group additionally saved more time on difficult tasks.

Conclusions

This study shows that 3D HD using a state-of-the-art 3D monitor permits superior task efficiency, even as compared with the latest 2D HD video systems.
Literature
1.
go back to reference Matouschek E, Becker H (1995) The value of 3D video endoscopy for surgical procedures. Bildgebung 62:174–178PubMed Matouschek E, Becker H (1995) The value of 3D video endoscopy for surgical procedures. Bildgebung 62:174–178PubMed
2.
go back to reference Buess GF, van Bergen P, Kunert W, Schurr MO (1996) Comparative study of various 2-D and 3-D vision systems in minimally invasive surgery. Chirurg 67:1041–1046PubMedCrossRef Buess GF, van Bergen P, Kunert W, Schurr MO (1996) Comparative study of various 2-D and 3-D vision systems in minimally invasive surgery. Chirurg 67:1041–1046PubMedCrossRef
3.
go back to reference van Bergen P, Kunert W, Bessell J, Buess GF (1998) Comparative study of two-dimensional and three-dimensional vision systems for minimally invasive surgery. Surg Endosc 12:948–954PubMedCrossRef van Bergen P, Kunert W, Bessell J, Buess GF (1998) Comparative study of two-dimensional and three-dimensional vision systems for minimally invasive surgery. Surg Endosc 12:948–954PubMedCrossRef
4.
go back to reference LaGrange CA, Clark CJ, Gerber EW, Strup SE (2008) Evaluation of three laparoscopic modalities: robotics versus three-dimensional vision laparoscopy versus standard laparoscopy. J Endourol 22:511–516PubMedCrossRef LaGrange CA, Clark CJ, Gerber EW, Strup SE (2008) Evaluation of three laparoscopic modalities: robotics versus three-dimensional vision laparoscopy versus standard laparoscopy. J Endourol 22:511–516PubMedCrossRef
5.
go back to reference Taffinder N, Smith SG, Huber J, Russell RC, Darzi A (1999) The effect of a second-generation 3D endoscope on the laparoscopic precision of novices and experienced surgeons. Surg Endosc 13:1087–1092PubMedCrossRef Taffinder N, Smith SG, Huber J, Russell RC, Darzi A (1999) The effect of a second-generation 3D endoscope on the laparoscopic precision of novices and experienced surgeons. Surg Endosc 13:1087–1092PubMedCrossRef
6.
go back to reference Kong SH, Oh BM, Yoon H, Ahn HS, Lee HJ, Chung SG, Shiraishi N, Kitano S, Yang HK (2010) Comparison of two- and three-dimensional camera systems in laparoscopic performance: a novel 3D system with one camera. Surg Endosc 24:1132–1143PubMedCrossRef Kong SH, Oh BM, Yoon H, Ahn HS, Lee HJ, Chung SG, Shiraishi N, Kitano S, Yang HK (2010) Comparison of two- and three-dimensional camera systems in laparoscopic performance: a novel 3D system with one camera. Surg Endosc 24:1132–1143PubMedCrossRef
7.
go back to reference Blavier A, Gaudissart Q, Cadiere GB, Nyssen AS (2006) Impact of 2D and 3D vision on performance of novice subjects using da Vinci robotic system. Acta Chir Belg 106:662–664PubMed Blavier A, Gaudissart Q, Cadiere GB, Nyssen AS (2006) Impact of 2D and 3D vision on performance of novice subjects using da Vinci robotic system. Acta Chir Belg 106:662–664PubMed
8.
go back to reference van Bergen P, Kunert W, Buess GF (2000) The effect of high-definition imaging on surgical task efficiency in minimally invasive surgery: an experimental comparison between three-dimensional imaging and direct vision through a stereoscopic TEM rectoscope. Surg Endosc 14:71–74PubMedCrossRef van Bergen P, Kunert W, Buess GF (2000) The effect of high-definition imaging on surgical task efficiency in minimally invasive surgery: an experimental comparison between three-dimensional imaging and direct vision through a stereoscopic TEM rectoscope. Surg Endosc 14:71–74PubMedCrossRef
9.
go back to reference Shah J, Buckley D, Frisby J, Darzi A (2003) Depth cue reliance in surgeons and medical students. Surg Endosc 17:1472–1474PubMedCrossRef Shah J, Buckley D, Frisby J, Darzi A (2003) Depth cue reliance in surgeons and medical students. Surg Endosc 17:1472–1474PubMedCrossRef
10.
go back to reference Brigner WL, Deni JR, Hildreth LL (1994) Simultaneous changes in length and direction as a cue for perceived depth. Percept Mot Skills 78:1385–1386PubMedCrossRef Brigner WL, Deni JR, Hildreth LL (1994) Simultaneous changes in length and direction as a cue for perceived depth. Percept Mot Skills 78:1385–1386PubMedCrossRef
11.
12.
13.
go back to reference Rogers B (2009) Motion parallax as an independent cue for depth perception: a retrospective. Perception 38:907–911PubMedCrossRef Rogers B (2009) Motion parallax as an independent cue for depth perception: a retrospective. Perception 38:907–911PubMedCrossRef
14.
go back to reference Voorhorst FA, Overbeeke KJ, Smets GJ (1996) Using movement parallax for 3D laparoscopy. Med Prog Technol 21:211–218PubMedCrossRef Voorhorst FA, Overbeeke KJ, Smets GJ (1996) Using movement parallax for 3D laparoscopy. Med Prog Technol 21:211–218PubMedCrossRef
15.
go back to reference Arezzo A, Kees T, Kunert W, De Gregori M, Buess G (2000) Shadow optic. An endoscope with optimized light. Chir Ital 52:451–453PubMed Arezzo A, Kees T, Kunert W, De Gregori M, Buess G (2000) Shadow optic. An endoscope with optimized light. Chir Ital 52:451–453PubMed
16.
go back to reference Buess G, Theiss R, Gunther M, Hutterer F, Pichlmaier H (1985) Endoscopic surgery in the rectum. Endoscopy 17:31–35PubMedCrossRef Buess G, Theiss R, Gunther M, Hutterer F, Pichlmaier H (1985) Endoscopic surgery in the rectum. Endoscopy 17:31–35PubMedCrossRef
17.
go back to reference Muller-Richter UD, Limberger A, Weber P, Schilling M (2003) Comparative study of spatial imaging techniques in stereo-endoscopy. Mund Kiefer Gesichtschir 7:157–163PubMedCrossRef Muller-Richter UD, Limberger A, Weber P, Schilling M (2003) Comparative study of spatial imaging techniques in stereo-endoscopy. Mund Kiefer Gesichtschir 7:157–163PubMedCrossRef
18.
go back to reference Inoue H, Tanaka H (1967) Relationship between abdnormal position of the eye and amblyopia, and angle of stereopsis for near object—mainly about the results due to stereotests. Nippon Ganka Gakkai Zasshi 71:92–97PubMed Inoue H, Tanaka H (1967) Relationship between abdnormal position of the eye and amblyopia, and angle of stereopsis for near object—mainly about the results due to stereotests. Nippon Ganka Gakkai Zasshi 71:92–97PubMed
19.
Metadata
Title
3D HD versus 2D HD: surgical task efficiency in standardised phantom tasks
Authors
Pirmin Storz
Gerhard F. Buess
Wolfgang Kunert
Andreas Kirschniak
Publication date
01-05-2012
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 5/2012
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-011-2055-9

Other articles of this Issue 5/2012

Surgical Endoscopy 5/2012 Go to the issue