Skip to main content
Top
Published in: Surgical Endoscopy 8/2011

01-08-2011

Novel method of the double-loop slip-knot: preknotting on the laparoscopic forceps enables easy and secure intracorporeal ligation

Authors: Takayuki Asao, So-ichi Tsutsumi, Yamaguchi Satoru, Takaaki Fujii, Erito Mochiki, Hiroyuki Kuwano

Published in: Surgical Endoscopy | Issue 8/2011

Login to get access

Abstract

Background

Laparoscopic ligation is a difficult and advanced technique because of the limited movement of forceps under two-dimensional videoscopic view. Currently, single-port surgery is widely used and a simple method for intracorporeal ligation is required. We describe an intracorporeal slip-knot with a double-loop strand that can be used to provide security and present the experimental results obtained.

Methods

A modified Eskimo bowline with a 4-0 absorbable monofilament was placed on a needle driver, and the forceps was used to grip both ends of the thread. Another forceps was used to pass the line under vessels in the abdominal cavity. The line was withdrawn from the gripping point through the preknot on the rod after it was gripped at the same point. The slip-knot was tightened, and a pushing forceps and a needle driver were used to push the knot and complete the ligation.

Results

The double-loop slip-knot has a high bursting pressure compatible with that of a conventional square-to-slip knot, which is significantly higher than that of any other slip-knot. In an experimental evaluation on animal laparoscopy, residents performed complete ligations of gastric and colonic arteries and veins within 30 s after a short explanation of the procedure.

Conclusion

This novel slip-knot with a double-strand loop could provide easy and secure intracorporeal ligation. This type of slip-knot has great potential for wide use in open surgery using laparoscopy. Further evaluation is required to determine its clinical applicability.
Literature
1.
go back to reference Asao T, Kuwano H, Mochiki E, Nakamura J, Shoji H, Shimura T, Fujita K (2001) A novel ligation forceps can be used as a ligature carrier and knot pusher during laparoscopic surgery. Surg Endosc 15:524–527PubMedCrossRef Asao T, Kuwano H, Mochiki E, Nakamura J, Shoji H, Shimura T, Fujita K (2001) A novel ligation forceps can be used as a ligature carrier and knot pusher during laparoscopic surgery. Surg Endosc 15:524–527PubMedCrossRef
2.
go back to reference Chiu AW, Wu ST, Sun GH, Liu CJ, Lin JJ, Tseng CY, Lin JT (2003) Novel intracorporeal vascular knot applier for large vessel ligation in laparoscopic surgery: experience in pigs and preliminary clinical use. J Endourol 17:73–78PubMedCrossRef Chiu AW, Wu ST, Sun GH, Liu CJ, Lin JJ, Tseng CY, Lin JT (2003) Novel intracorporeal vascular knot applier for large vessel ligation in laparoscopic surgery: experience in pigs and preliminary clinical use. J Endourol 17:73–78PubMedCrossRef
3.
go back to reference Lim BS (1996) Intracorporeal ligation of the cystic duct during laparoscopic cholecystectomy. Surg Laparosc Endosc 6:388–391PubMedCrossRef Lim BS (1996) Intracorporeal ligation of the cystic duct during laparoscopic cholecystectomy. Surg Laparosc Endosc 6:388–391PubMedCrossRef
4.
go back to reference Olmi S, Croce E (2003) Scissor-knot-pusher: an instrument for simplified laparoscopic extracorporeal knotting. JSLS 7:281–284PubMed Olmi S, Croce E (2003) Scissor-knot-pusher: an instrument for simplified laparoscopic extracorporeal knotting. JSLS 7:281–284PubMed
5.
go back to reference Jaffer U (2009) Forming an intracorporeal slip-knot in laparoscopic suturing. Can J Surg 52:E23–E24PubMed Jaffer U (2009) Forming an intracorporeal slip-knot in laparoscopic suturing. Can J Surg 52:E23–E24PubMed
6.
go back to reference Chi T, Eisner BH, Berger AD, Stoller ML (2010) An ex-vivo evaluation of the application and strength of a novel laparoscopic knot substitute device. J Endourol 24:95–98PubMedCrossRef Chi T, Eisner BH, Berger AD, Stoller ML (2010) An ex-vivo evaluation of the application and strength of a novel laparoscopic knot substitute device. J Endourol 24:95–98PubMedCrossRef
7.
go back to reference Asao T, Yamaguchi S, Tsutsumi S, Mochiki E, Kuwano H (2007) Experimental results and early clinical experience with an easy method for intracorporeal knot tying using a novel laparoscopic needleholder. Surg Endosc 21:1553–1556PubMedCrossRef Asao T, Yamaguchi S, Tsutsumi S, Mochiki E, Kuwano H (2007) Experimental results and early clinical experience with an easy method for intracorporeal knot tying using a novel laparoscopic needleholder. Surg Endosc 21:1553–1556PubMedCrossRef
8.
go back to reference Meier JD, Meier SW (2007) Over-pointing technique: an approach to past-pointing arthroscopic knots on alternating suture posts without alternating the knot pusher. Arthroscopy 23:1358.e1–1358.e3CrossRef Meier JD, Meier SW (2007) Over-pointing technique: an approach to past-pointing arthroscopic knots on alternating suture posts without alternating the knot pusher. Arthroscopy 23:1358.e1–1358.e3CrossRef
9.
go back to reference Barto W, Chen S (2003) Improved design knot pusher for laparoscopic extracorporeal suturing. ANZ J Surg 73:162PubMedCrossRef Barto W, Chen S (2003) Improved design knot pusher for laparoscopic extracorporeal suturing. ANZ J Surg 73:162PubMedCrossRef
10.
go back to reference Araujo MB, Andreoni C, Bomfim AC, Ortiz V, Ferreira PS, Figueiredo LP, Srougi M (2005) The Boatman’s knot: a single knot for renal-vein ligation during laparoscopic nephrectomy: description of technique and evaluation of feasibility and safety. J Endourol 19:1134–1139PubMedCrossRef Araujo MB, Andreoni C, Bomfim AC, Ortiz V, Ferreira PS, Figueiredo LP, Srougi M (2005) The Boatman’s knot: a single knot for renal-vein ligation during laparoscopic nephrectomy: description of technique and evaluation of feasibility and safety. J Endourol 19:1134–1139PubMedCrossRef
11.
go back to reference Bomfim AC, Andreoni C, Miotto A, Araújo MB, Ortiz V, de Figueiredo LF, Srougi M (2005) The “Boatman’s knot”: a new option for renal hilum ligation during laparoscopic nephrectomy. Acta Cir Bras 20:258–261PubMedCrossRef Bomfim AC, Andreoni C, Miotto A, Araújo MB, Ortiz V, de Figueiredo LF, Srougi M (2005) The “Boatman’s knot”: a new option for renal hilum ligation during laparoscopic nephrectomy. Acta Cir Bras 20:258–261PubMedCrossRef
12.
go back to reference Bucher P, Pugin F, Morel P (2009) Single-port access laparoscopic radical left colectomy in humans. Dis Colon Rectum 52:1797–1801PubMedCrossRef Bucher P, Pugin F, Morel P (2009) Single-port access laparoscopic radical left colectomy in humans. Dis Colon Rectum 52:1797–1801PubMedCrossRef
13.
go back to reference Langwieler TE, Nimmesgern T, Back M (2009) Single-port access in laparoscopic cholecystectomy. Surg Endosc 23:1138–1141PubMedCrossRef Langwieler TE, Nimmesgern T, Back M (2009) Single-port access in laparoscopic cholecystectomy. Surg Endosc 23:1138–1141PubMedCrossRef
14.
go back to reference Aron M, Canes D, Desai MM, Haber GP, Kaouk JH, Gill IS (2009) Transumbilical single-port laparoscopic partial nephrectomy. BJU Int 103:516–521PubMedCrossRef Aron M, Canes D, Desai MM, Haber GP, Kaouk JH, Gill IS (2009) Transumbilical single-port laparoscopic partial nephrectomy. BJU Int 103:516–521PubMedCrossRef
15.
go back to reference Co CS, Cheung HY, Yau KK, Chung CC, Li M (2010) Combined single-port and endoluminal technique for laparoscopic anterior resection. Surg Laparosc Endosc Percutan Tech 20:253–256PubMedCrossRef Co CS, Cheung HY, Yau KK, Chung CC, Li M (2010) Combined single-port and endoluminal technique for laparoscopic anterior resection. Surg Laparosc Endosc Percutan Tech 20:253–256PubMedCrossRef
16.
go back to reference Boni L, Dionigi G, Cassinotti E, Di Giuseppe M, Diurni M, Rausei S, Cantore F, Dionigi R (2010) Single incision laparoscopic right colectomy. Surg Endosc 24(12):3233–3236PubMedCrossRef Boni L, Dionigi G, Cassinotti E, Di Giuseppe M, Diurni M, Rausei S, Cantore F, Dionigi R (2010) Single incision laparoscopic right colectomy. Surg Endosc 24(12):3233–3236PubMedCrossRef
17.
go back to reference Huang CK, Yao SF, Lo CH, Houng JY, Chen YS, Lee PH (2010) A novel surgical technique: single-incision transumbilical laparoscopic Roux-en-Y gastric bypass. Obes Surg 20:1429–1435PubMedCrossRef Huang CK, Yao SF, Lo CH, Houng JY, Chen YS, Lee PH (2010) A novel surgical technique: single-incision transumbilical laparoscopic Roux-en-Y gastric bypass. Obes Surg 20:1429–1435PubMedCrossRef
Metadata
Title
Novel method of the double-loop slip-knot: preknotting on the laparoscopic forceps enables easy and secure intracorporeal ligation
Authors
Takayuki Asao
So-ichi Tsutsumi
Yamaguchi Satoru
Takaaki Fujii
Erito Mochiki
Hiroyuki Kuwano
Publication date
01-08-2011
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 8/2011
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-010-1570-4

Other articles of this Issue 8/2011

Surgical Endoscopy 8/2011 Go to the issue

Letter--Reply

Author reply