Skip to main content
Top
Published in: Surgical Endoscopy 11/2010

01-11-2010

Staple line reinforcement in laparoscopic bariatric surgery: does it actually make a difference? A systematic review and meta-analysis

Authors: George A. Giannopoulos, Nikolaos E. Tzanakis, George E. Rallis, Stamatis P. Efstathiou, Christos Tsigris, Nikolaos I. Nikiteas

Published in: Surgical Endoscopy | Issue 11/2010

Login to get access

Abstract

Background

Staple line leaks represent a major concern in all laparoscopic operations but are particularly important in bariatric surgery, where leak complications carry significant morbidity and mortality. Therefore, several means of staple line reinforcement have been described, but none is totally accepted. In this study, we attempt to illuminate any clear benefit of staple line reinforcement through a systematic review and meta-analysis of reported articles.

Methods

Two major databases (PubMed and Cochrane) were searched and assessed by two reviewers. Inclusion criteria were: detailed description of operative technique, especially concerning staple line reinforcement, and possible existence of proven staple line leak. Selected studies were evaluated by systematic review and meta-analysis according to their eligibility. The study population was finally divided into two groups: reinforcement (of any type) and no reinforcement.

Results

In the initial search, 126 studies were obtained. Then, 17 full papers, both randomised controlled trials (RCTs) and non-RCTs, were included in the systematic review. Seven studies, comprising 3,299 patients, were examined for evaluation of population odds of leak (7.69), which was considered clinically significant. Meta-analysis of three studies comprising 1,899 patients revealed no clear benefit of reinforcement group, though with marginal significance.

Conclusions

Although several drawbacks exist, this study illustrates two important aspects: that current staplers may not be uniformly reliable, and that staple line reinforcement does not seem to have any clear benefit, at least concerning leak rate.
Literature
1.
go back to reference Baker RS, Foote J, Kemmeter P, Brady R, Vroegop T, Serveld M (2004) The science of stapling and leaks. Obes Surg 14:1290–1298CrossRefPubMed Baker RS, Foote J, Kemmeter P, Brady R, Vroegop T, Serveld M (2004) The science of stapling and leaks. Obes Surg 14:1290–1298CrossRefPubMed
2.
go back to reference Marecik SJ, Chaudhry V, Jan A, Pearl RK, Park JJ, Prasad LM (2007) A comparison of robotic, laparoscopic, and hand-sewn intestinal sutured anastomoses performed by residents. Am J Surg 193:349–355 discussion 355CrossRefPubMed Marecik SJ, Chaudhry V, Jan A, Pearl RK, Park JJ, Prasad LM (2007) A comparison of robotic, laparoscopic, and hand-sewn intestinal sutured anastomoses performed by residents. Am J Surg 193:349–355 discussion 355CrossRefPubMed
3.
go back to reference Basu NN, Leschinskey D, Heath DI (2008) The use of Seamguard to buttress the suture repair of a staple line leak following laparoscopic gastric bypass for obesity. Obes Surg 18:896–897CrossRefPubMed Basu NN, Leschinskey D, Heath DI (2008) The use of Seamguard to buttress the suture repair of a staple line leak following laparoscopic gastric bypass for obesity. Obes Surg 18:896–897CrossRefPubMed
4.
go back to reference Podnos YD, Jimenez JC, Wilson SE, Stevens CM, Nguyen NT (2003) Complications after laparoscopic gastric bypass: a review of 3464 cases. Arch Surg 138:957–961CrossRefPubMed Podnos YD, Jimenez JC, Wilson SE, Stevens CM, Nguyen NT (2003) Complications after laparoscopic gastric bypass: a review of 3464 cases. Arch Surg 138:957–961CrossRefPubMed
5.
go back to reference Fullum TM, Aluka KJ, Turner PL (2009) Decreasing anastomotic and staple line leaks after laparoscopic Roux-en-Y gastric bypass. Surg Endosc 23(6):1403–1408CrossRef Fullum TM, Aluka KJ, Turner PL (2009) Decreasing anastomotic and staple line leaks after laparoscopic Roux-en-Y gastric bypass. Surg Endosc 23(6):1403–1408CrossRef
6.
7.
go back to reference Bax L, Yu LM, Ikeda N, Tsuruta H, Moons KG (2006) Development and validation of MIX: comprehensive free software for meta-analysis of causal research data. BMC Med Res Methodol 6:50CrossRefPubMed Bax L, Yu LM, Ikeda N, Tsuruta H, Moons KG (2006) Development and validation of MIX: comprehensive free software for meta-analysis of causal research data. BMC Med Res Methodol 6:50CrossRefPubMed
8.
go back to reference Sutton AJ, Abrams KR, Jones DR, Sheldon TA (2000) Methods for meta-analysis in medical research, 1st edn. Wiley, London Sutton AJ, Abrams KR, Jones DR, Sheldon TA (2000) Methods for meta-analysis in medical research, 1st edn. Wiley, London
9.
go back to reference Kasalicky M, Michalsky D, Housova J, Haluzik M, Housa D, Haluzikova D, Fried M (2008) Laparoscopic sleeve gastrectomy without an over-sewing of the staple line. Obes Surg 18:1257–1262CrossRefPubMed Kasalicky M, Michalsky D, Housova J, Haluzik M, Housa D, Haluzikova D, Fried M (2008) Laparoscopic sleeve gastrectomy without an over-sewing of the staple line. Obes Surg 18:1257–1262CrossRefPubMed
10.
go back to reference Jones WB, Myers KM, Traxler LB, Bour ES (2008) Clinical results using bioabsorbable staple line reinforcement for circular staplers. Am Surg 74:462–467 discussion 467-468PubMed Jones WB, Myers KM, Traxler LB, Bour ES (2008) Clinical results using bioabsorbable staple line reinforcement for circular staplers. Am Surg 74:462–467 discussion 467-468PubMed
11.
go back to reference Chen B, Kiriakopoulos A, Tsakayannis D, Wachtel MS, Linos D, Frezza EE (2009) Reinforcement does not necessarily reduce the rate of staple line leaks after sleeve gastrectomy. A review of the literature and clinical experiences. Obes Surg 19:166–172CrossRefPubMed Chen B, Kiriakopoulos A, Tsakayannis D, Wachtel MS, Linos D, Frezza EE (2009) Reinforcement does not necessarily reduce the rate of staple line leaks after sleeve gastrectomy. A review of the literature and clinical experiences. Obes Surg 19:166–172CrossRefPubMed
12.
go back to reference Arnold W, Shikora SA (2005) A comparison of burst pressure between buttressed versus non-buttressed staple-lines in an animal model. Obes Surg 15:164–171CrossRefPubMed Arnold W, Shikora SA (2005) A comparison of burst pressure between buttressed versus non-buttressed staple-lines in an animal model. Obes Surg 15:164–171CrossRefPubMed
13.
go back to reference Shikora SA, Kim JJ, Tarnoff ME (2008) Comparison of permanent and nonpermanent staple line buttressing materials for linear gastric staple lines during laparoscopic Roux-en-Y gastric bypass. Surg Obes Relat Dis 4:729–734CrossRefPubMed Shikora SA, Kim JJ, Tarnoff ME (2008) Comparison of permanent and nonpermanent staple line buttressing materials for linear gastric staple lines during laparoscopic Roux-en-Y gastric bypass. Surg Obes Relat Dis 4:729–734CrossRefPubMed
14.
go back to reference Schweitzer MA, Lidor A, Magnuson TH (2006) A zero leak rate in 251 consecutive laparoscopic gastric bypass operations using a two-layer gastrojejunostomy technique. J Laparoendosc Adv Surg Tech A 16:83–87CrossRefPubMed Schweitzer MA, Lidor A, Magnuson TH (2006) A zero leak rate in 251 consecutive laparoscopic gastric bypass operations using a two-layer gastrojejunostomy technique. J Laparoendosc Adv Surg Tech A 16:83–87CrossRefPubMed
15.
go back to reference Nguyen NT, Nguyen CT, Stevens CM, Steward E, Paya M (2004) The efficacy of fibrin sealant in prevention of anastomotic leak after laparoscopic gastric bypass. J Surg Res 122:218–224CrossRefPubMed Nguyen NT, Nguyen CT, Stevens CM, Steward E, Paya M (2004) The efficacy of fibrin sealant in prevention of anastomotic leak after laparoscopic gastric bypass. J Surg Res 122:218–224CrossRefPubMed
16.
go back to reference DeMaria EJ, Sugerman HJ, Kellum JM, Meador JG, Wolfe LG (2002) Results of 281 consecutive total laparoscopic Roux-en-Y gastric bypasses to treat morbid obesity. Ann Surg 235:640–645 discussion 645-647CrossRefPubMed DeMaria EJ, Sugerman HJ, Kellum JM, Meador JG, Wolfe LG (2002) Results of 281 consecutive total laparoscopic Roux-en-Y gastric bypasses to treat morbid obesity. Ann Surg 235:640–645 discussion 645-647CrossRefPubMed
17.
go back to reference Saber AA, Scharf KR, Turk AZ, Elgamal MH, Martinez RL (2008) Early experience with intraluminal reinforcement of stapled gastrojejunostomy during laparoscopic Roux-en-Y gastric bypass. Obes Surg 18:525–529CrossRefPubMed Saber AA, Scharf KR, Turk AZ, Elgamal MH, Martinez RL (2008) Early experience with intraluminal reinforcement of stapled gastrojejunostomy during laparoscopic Roux-en-Y gastric bypass. Obes Surg 18:525–529CrossRefPubMed
18.
go back to reference Miller KA, Pump A (2007) Use of bioabsorbable staple reinforcement material in gastric bypass: a prospective randomized clinical trial. Surg Obes Relat Dis 3:417–421 discussion 422CrossRefPubMed Miller KA, Pump A (2007) Use of bioabsorbable staple reinforcement material in gastric bypass: a prospective randomized clinical trial. Surg Obes Relat Dis 3:417–421 discussion 422CrossRefPubMed
19.
go back to reference Gonzalez R, Haines K, Gallagher SF, Murr MM (2006) Does experience preclude leaks in laparoscopic gastric bypass? Surg Endosc 20:1687–1692CrossRefPubMed Gonzalez R, Haines K, Gallagher SF, Murr MM (2006) Does experience preclude leaks in laparoscopic gastric bypass? Surg Endosc 20:1687–1692CrossRefPubMed
20.
go back to reference Dapri G, Vaz C, Cadiere GB, Himpens J (2007) A prospective randomized study comparing two different techniques for laparoscopic sleeve gastrectomy. Obes Surg 17:1435–1441CrossRefPubMed Dapri G, Vaz C, Cadiere GB, Himpens J (2007) A prospective randomized study comparing two different techniques for laparoscopic sleeve gastrectomy. Obes Surg 17:1435–1441CrossRefPubMed
21.
go back to reference Nocca D, Aggarwal R, Blanc P, Gallix B, Di Mauro GL, Millat B, Seguin des De Hons C, Deneve E, Rodier JG, Tincani G, Pierredon MA, Fabre JM (2007) Laparoscopic vertical banded gastroplasty. A multicenter prospective study of 200 procedures. Surg Endosc 21:870–874CrossRefPubMed Nocca D, Aggarwal R, Blanc P, Gallix B, Di Mauro GL, Millat B, Seguin des De Hons C, Deneve E, Rodier JG, Tincani G, Pierredon MA, Fabre JM (2007) Laparoscopic vertical banded gastroplasty. A multicenter prospective study of 200 procedures. Surg Endosc 21:870–874CrossRefPubMed
22.
go back to reference Simper SC, Erzinger JM, Smith SC (2007) Comparison of laparoscopic linear staplers in clinical practice. Surg Obes Relat Dis 3:446–450 discussion 450-441CrossRefPubMed Simper SC, Erzinger JM, Smith SC (2007) Comparison of laparoscopic linear staplers in clinical practice. Surg Obes Relat Dis 3:446–450 discussion 450-441CrossRefPubMed
23.
go back to reference Givon-Madhala O, Spector R, Wasserberg N, Beglaibter N, Lustigman H, Stein M, Arar N, Rubin M (2007) Technical aspects of laparoscopic sleeve gastrectomy in 25 morbidly obese patients. Obes Surg 17:722–727CrossRefPubMed Givon-Madhala O, Spector R, Wasserberg N, Beglaibter N, Lustigman H, Stein M, Arar N, Rubin M (2007) Technical aspects of laparoscopic sleeve gastrectomy in 25 morbidly obese patients. Obes Surg 17:722–727CrossRefPubMed
24.
go back to reference Baltasar A, Serra C, Perez N, Bou R, Bengochea M, Ferri L (2005) Laparoscopic sleeve gastrectomy: a multi-purpose bariatric operation. Obes Surg 15:1124–1128CrossRefPubMed Baltasar A, Serra C, Perez N, Bou R, Bengochea M, Ferri L (2005) Laparoscopic sleeve gastrectomy: a multi-purpose bariatric operation. Obes Surg 15:1124–1128CrossRefPubMed
25.
go back to reference Consten EC, Gagner M, Pomp A, Inabnet WB (2004) Decreased bleeding after laparoscopic sleeve gastrectomy with or without duodenal switch for morbid obesity using a stapled buttressed absorbable polymer membrane. Obes Surg 14:1360–1366CrossRefPubMed Consten EC, Gagner M, Pomp A, Inabnet WB (2004) Decreased bleeding after laparoscopic sleeve gastrectomy with or without duodenal switch for morbid obesity using a stapled buttressed absorbable polymer membrane. Obes Surg 14:1360–1366CrossRefPubMed
Metadata
Title
Staple line reinforcement in laparoscopic bariatric surgery: does it actually make a difference? A systematic review and meta-analysis
Authors
George A. Giannopoulos
Nikolaos E. Tzanakis
George E. Rallis
Stamatis P. Efstathiou
Christos Tsigris
Nikolaos I. Nikiteas
Publication date
01-11-2010
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 11/2010
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-010-1047-5

Other articles of this Issue 11/2010

Surgical Endoscopy 11/2010 Go to the issue