Skip to main content
Top
Published in: Surgical Endoscopy 4/2008

01-04-2008

Immunohistochemical analysis of host reaction to heavyweight-, reduced-weight-, and expanded polytetrafluoroethylene (ePTFE)-based meshes after short- and long-term intraabdominal implantations

Authors: Y. W. Novitsky, J. A. Cristiano, A. G. Harrell, W. Newcomb, J. H. Norton, K. W. Kercher, B. T. Heniford

Published in: Surgical Endoscopy | Issue 4/2008

Login to get access

Abstract

Background

Prosthetic meshes induce a variety of inflammatory changes in the host, which may lead to excessive scarring with detrimental clinical consequences, especially in the long term. This study aimed to characterize the degree of short- and long-term inflammatory changes induced by common prosthetic meshes.

Methods

Twenty 4 × 4-cm samples each of expanded polytetrafluoroethylene (ePTFE), heavyweight polypropylene (hPP), ePTFE/heavyweight polypropylene (ePTFE/hPP), and reduced-weight polypropylene/regenerated cellulose (rPP) were implanted intraperitoneally in 40 rabbits for 4 or 12 months. After explantation, samples of mesh/tissue complex were analyzed for the degrees of cellular apoptosis (enzyme-linked immunoassay [ELISA]) and cellular turnover (mouse monoclonal antibody).

Results

In the short term, the degree of apoptosis in the hPP mesh was significantly higher than in the ePTFE and rPP groups. Similarly, it was higher in the ePTFE/hPP group than in either the ePTFE or the rPP group. The amount of Ki-67-positive cells was significantly higher in the hPP group than in the ePTFE or rPP group. The cell turnover in the ePTFE/hPP group was similar to that in the hPP group, but significantly higher than in either the ePTFE or the rPP group. The rPP group, in turn, had a higher Ki-67 score than the ePTFE group. In the long term, both the degree of apoptosis and Ki-67 positivity were significantly lower in the rPP and ePTFE groups than in either the ePTFE/hPP or the hPP group. A significant decrease in Ki-67 scores between the short and long-term groups was found only in the rPP group.

Conclusion

In the short term, heavyweight polypropylene-based meshes were associated with significantly higher cell proliferation and death. A significantly higher degree of apoptosis and cell turnover were associated with heavyweight polypropylene-based meshes even 1 year after implantation, indicating ongoing inflammation and scar remodeling. On the other hand, ePTFE and reduced-weight polypropylene meshes were associated with nearly physiologic levels of inflammatory markers. Overall, an exaggerated and persistent host foreign body response to heavyweight polypropylene-based meshes indicates poor biocompatibility, with potential detrimental clinical sequela.
Literature
1.
2.
go back to reference Novitsky YW, Harrell AG, Cristiano JA, Paton BL, Norton HJ, Peindl RD, Kercher KW, Heniford BT (2007) Comparative evaluation of adhesion formation, strength of ingrowth, and textile properties of prosthetic meshes after long-term intra-abdominal implantation in a rabbit. J Surg Res 140:6–11PubMedCrossRef Novitsky YW, Harrell AG, Cristiano JA, Paton BL, Norton HJ, Peindl RD, Kercher KW, Heniford BT (2007) Comparative evaluation of adhesion formation, strength of ingrowth, and textile properties of prosthetic meshes after long-term intra-abdominal implantation in a rabbit. J Surg Res 140:6–11PubMedCrossRef
3.
go back to reference Novitsky YW, Harrell AG, Hope WW, Kercher KW, Heniford BT (2007) Meshes in hernia repair. Surg Technol Int 16:123–127PubMed Novitsky YW, Harrell AG, Hope WW, Kercher KW, Heniford BT (2007) Meshes in hernia repair. Surg Technol Int 16:123–127PubMed
4.
go back to reference Greca FH, de Paula JB, Biondo-Simões ML, da Costa FD, da Silva AP, Time S, Mansur A (2001) The influence of differing pore sizes on the biocompatibility of two polypropylene meshes in the repair of abdominal defects: experimental study in dogs. Hernia 5:59–64PubMedCrossRef Greca FH, de Paula JB, Biondo-Simões ML, da Costa FD, da Silva AP, Time S, Mansur A (2001) The influence of differing pore sizes on the biocompatibility of two polypropylene meshes in the repair of abdominal defects: experimental study in dogs. Hernia 5:59–64PubMedCrossRef
5.
go back to reference Klosterhalfen B, Junge K, Klinge U (2005) The lightweight and large porous mesh concept for hernia repair. Expert Rev Med Devices 2:103–117PubMedCrossRef Klosterhalfen B, Junge K, Klinge U (2005) The lightweight and large porous mesh concept for hernia repair. Expert Rev Med Devices 2:103–117PubMedCrossRef
6.
go back to reference Cobb WS, Kercher KW, Heniford BT (2005) The argument for lightweight polypropylene mesh in hernia repair. Surg Innov 12:63–69PubMedCrossRef Cobb WS, Kercher KW, Heniford BT (2005) The argument for lightweight polypropylene mesh in hernia repair. Surg Innov 12:63–69PubMedCrossRef
7.
go back to reference Harrell AG, Novitsky YW, Peindl RD, Cobb WS, Austin CE, Cristiano JA, Norton JH, Kercher KW, Heniford BT (2006) Prospective evaluation of adhesion formation and shrinkage of intra-abdominal prosthetics in a rabbit model. Am Surg 72:808–813, discussion 813–814PubMed Harrell AG, Novitsky YW, Peindl RD, Cobb WS, Austin CE, Cristiano JA, Norton JH, Kercher KW, Heniford BT (2006) Prospective evaluation of adhesion formation and shrinkage of intra-abdominal prosthetics in a rabbit model. Am Surg 72:808–813, discussion 813–814PubMed
8.
go back to reference Klinge U, Klosterhalfen B, Muller M, Schumpelick V (1999) Foreign body reaction to meshes used for the repair of abdominal wall hernias. Eur J Surg 165:665–673PubMedCrossRef Klinge U, Klosterhalfen B, Muller M, Schumpelick V (1999) Foreign body reaction to meshes used for the repair of abdominal wall hernias. Eur J Surg 165:665–673PubMedCrossRef
9.
go back to reference Matthews BD, Mostafa G, Carbonell AM, Joels CS, Kercher KW, Austin C, Norton HJ, Heniford BT (2005) Evaluation of adhesion formation and host tissue response to intra-abdominal polytetrafluoroethylene mesh and composite prosthetic mesh. J Surg Res 123:227–234PubMedCrossRef Matthews BD, Mostafa G, Carbonell AM, Joels CS, Kercher KW, Austin C, Norton HJ, Heniford BT (2005) Evaluation of adhesion formation and host tissue response to intra-abdominal polytetrafluoroethylene mesh and composite prosthetic mesh. J Surg Res 123:227–234PubMedCrossRef
10.
go back to reference Heniford BT, Park A, Ramshaw BJ, Voeller G (2003) Laparoscopic repair of ventral hernias: nine years’ experience with 850 consecutive hernias. Ann Surg 238:391–399, discussion 399–400PubMed Heniford BT, Park A, Ramshaw BJ, Voeller G (2003) Laparoscopic repair of ventral hernias: nine years’ experience with 850 consecutive hernias. Ann Surg 238:391–399, discussion 399–400PubMed
11.
go back to reference Carbajo MA, Martín del Olmo JC, Blanco JI, de la Cuesta C, Toledano M, Martin F, Vaquero C, Inglada L (1999) Laparoscopic treatment vs open surgery in the solution of major incisional and abdominal wall hernias with mesh. Surg Endosc 13:250–252PubMedCrossRef Carbajo MA, Martín del Olmo JC, Blanco JI, de la Cuesta C, Toledano M, Martin F, Vaquero C, Inglada L (1999) Laparoscopic treatment vs open surgery in the solution of major incisional and abdominal wall hernias with mesh. Surg Endosc 13:250–252PubMedCrossRef
12.
go back to reference Novitsky YW, Cobb WS, Kercher KW, Matthews BD, Sing RF, Heniford BT (2006) Laparoscopic ventral hernia repair in obese patients: a new standard of care. Arch Surg 141:57–61PubMedCrossRef Novitsky YW, Cobb WS, Kercher KW, Matthews BD, Sing RF, Heniford BT (2006) Laparoscopic ventral hernia repair in obese patients: a new standard of care. Arch Surg 141:57–61PubMedCrossRef
13.
go back to reference Leber GE, Garb JL, Alexander AI, Reed WP (1998) Long-term complications associated with prosthetic repair of incisional hernias. Arch Surg 133:378–382PubMedCrossRef Leber GE, Garb JL, Alexander AI, Reed WP (1998) Long-term complications associated with prosthetic repair of incisional hernias. Arch Surg 133:378–382PubMedCrossRef
14.
go back to reference Matthews BD, Pratt BL, Pollinger HS, Backus CL, Kercher KW, Sing RF, Heniford BT (2003) Assessment of adhesion formation to intra-abdominal polypropylene mesh and polytetrafluoroethylene mesh. J Surg Res 114:126–132PubMedCrossRef Matthews BD, Pratt BL, Pollinger HS, Backus CL, Kercher KW, Sing RF, Heniford BT (2003) Assessment of adhesion formation to intra-abdominal polypropylene mesh and polytetrafluoroethylene mesh. J Surg Res 114:126–132PubMedCrossRef
15.
go back to reference Welty G, Klinge U, Klosterhalfen B, Kasperk R, Schumpelick V (2001) Functional impairment and complaints following incisional hernia repair with different polypropylene meshes. Hernia 5:142–147PubMedCrossRef Welty G, Klinge U, Klosterhalfen B, Kasperk R, Schumpelick V (2001) Functional impairment and complaints following incisional hernia repair with different polypropylene meshes. Hernia 5:142–147PubMedCrossRef
16.
go back to reference Rosch R, Junge K, Schachtrupp A, Klinge U, Klosterhalfen B, Schumpelick V (2003) Mesh implants in hernia repair: inflammatory cell response in a rat model. Eur Surg Res 35:161–166PubMedCrossRef Rosch R, Junge K, Schachtrupp A, Klinge U, Klosterhalfen B, Schumpelick V (2003) Mesh implants in hernia repair: inflammatory cell response in a rat model. Eur Surg Res 35:161–166PubMedCrossRef
17.
go back to reference Harrell AG, Novitsky YW, Cristiano JA, Gersin KS, Norton HJ, Kercher KW, Heniford BT (2007) Prospective histologic evaluation of intra-abdominal prosthetics four months after implantation in a rabbit model. Surg Endosc 21:1170–1174PubMedCrossRef Harrell AG, Novitsky YW, Cristiano JA, Gersin KS, Norton HJ, Kercher KW, Heniford BT (2007) Prospective histologic evaluation of intra-abdominal prosthetics four months after implantation in a rabbit model. Surg Endosc 21:1170–1174PubMedCrossRef
18.
go back to reference Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res 103:208–214PubMedCrossRef Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res 103:208–214PubMedCrossRef
19.
go back to reference Scheidbach H, Tamme C, Tannapfel A, Lippert H, Köckerling F (2004) In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty: an experimental study in pigs. Surg Endosc 18:211–220PubMedCrossRef Scheidbach H, Tamme C, Tannapfel A, Lippert H, Köckerling F (2004) In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty: an experimental study in pigs. Surg Endosc 18:211–220PubMedCrossRef
20.
go back to reference Gonzalez R, Fugate K, McClusky D III, Ritter EM, Lederman A, Dillehay D, Smith CD, Ramshaw BJ (2005) Relationship between tissue ingrowth and mesh contraction. World J Surg 29:1038–1043PubMedCrossRef Gonzalez R, Fugate K, McClusky D III, Ritter EM, Lederman A, Dillehay D, Smith CD, Ramshaw BJ (2005) Relationship between tissue ingrowth and mesh contraction. World J Surg 29:1038–1043PubMedCrossRef
21.
go back to reference Junge K, Klinge U, Klosterhalfen B, Mertens PR, Rosch R, Schachtrupp A, Ulmer F, Schumpelick V (2002) Influence of mesh materials on collagen deposition in a rat model. J Invest Surg 15:319–328PubMedCrossRef Junge K, Klinge U, Klosterhalfen B, Mertens PR, Rosch R, Schachtrupp A, Ulmer F, Schumpelick V (2002) Influence of mesh materials on collagen deposition in a rat model. J Invest Surg 15:319–328PubMedCrossRef
22.
go back to reference Marois Y, Cadi R, Gourdon J, Fatouraee N, King MW, Zhang Z, Guidoin R (2000) Biostability, inflammatory response, and healing characteristics of a fluoropassivated polyester-knit mesh in the repair of experimental abdominal hernias. Artif Organs 24:533–543PubMedCrossRef Marois Y, Cadi R, Gourdon J, Fatouraee N, King MW, Zhang Z, Guidoin R (2000) Biostability, inflammatory response, and healing characteristics of a fluoropassivated polyester-knit mesh in the repair of experimental abdominal hernias. Artif Organs 24:533–543PubMedCrossRef
23.
go back to reference Post S, Weiss B, Willer M, Neufang T, Lorenz D (2004) Randomized clinical trial of lightweight composite mesh for Lichtenstein inguinal hernia repair. Br J Surg 91:44–48PubMedCrossRef Post S, Weiss B, Willer M, Neufang T, Lorenz D (2004) Randomized clinical trial of lightweight composite mesh for Lichtenstein inguinal hernia repair. Br J Surg 91:44–48PubMedCrossRef
24.
go back to reference O’Dwyer PJ, Alani A, McConnachie A (2005) Groin hernia repair: postherniorrhaphy pain. World J Surg 29:1062–1065PubMedCrossRef O’Dwyer PJ, Alani A, McConnachie A (2005) Groin hernia repair: postherniorrhaphy pain. World J Surg 29:1062–1065PubMedCrossRef
25.
go back to reference Gerdes J, Lemke H, Baisch H, Wacker HH, Schwab U, Stein H (1984) Cell cycle analysis of a cell proliferation-associated human nuclear antigen defined by the monoclonal antibody Ki-67. J Immunol 133:1710–1715PubMed Gerdes J, Lemke H, Baisch H, Wacker HH, Schwab U, Stein H (1984) Cell cycle analysis of a cell proliferation-associated human nuclear antigen defined by the monoclonal antibody Ki-67. J Immunol 133:1710–1715PubMed
26.
go back to reference Ben-Izhak O, Laster Z, Araidy S, Nagler RM (2007) TUNEL—an efficient prognosis predictor of salivary malignancies. Br J Cancer 96:1101–1106PubMedCrossRef Ben-Izhak O, Laster Z, Araidy S, Nagler RM (2007) TUNEL—an efficient prognosis predictor of salivary malignancies. Br J Cancer 96:1101–1106PubMedCrossRef
27.
go back to reference Junge K, Klinge U, Rosch R, Klosterhalfen B, Schumpelick V (2002) Functional and morphologic properties of a modified mesh for inguinal hernia repair. World J Surg 26:1472–1480PubMedCrossRef Junge K, Klinge U, Rosch R, Klosterhalfen B, Schumpelick V (2002) Functional and morphologic properties of a modified mesh for inguinal hernia repair. World J Surg 26:1472–1480PubMedCrossRef
28.
go back to reference Klinge U, Junge K, Stumpf M, AP AP, Klosterhalfen B (2002) Functional and morphological evaluation of a low-weight, monofilament polypropylene mesh for hernia repair. J Biomed Mater Res 63:129–136PubMedCrossRef Klinge U, Junge K, Stumpf M, AP AP, Klosterhalfen B (2002) Functional and morphological evaluation of a low-weight, monofilament polypropylene mesh for hernia repair. J Biomed Mater Res 63:129–136PubMedCrossRef
29.
go back to reference Klosterhalfen B, Junge K, Hermanns B, Klinge U (2002) Influence of implantation interval on the long-term biocompatibility of surgical mesh. Br J Surg 89:1043–1048PubMedCrossRef Klosterhalfen B, Junge K, Hermanns B, Klinge U (2002) Influence of implantation interval on the long-term biocompatibility of surgical mesh. Br J Surg 89:1043–1048PubMedCrossRef
Metadata
Title
Immunohistochemical analysis of host reaction to heavyweight-, reduced-weight-, and expanded polytetrafluoroethylene (ePTFE)-based meshes after short- and long-term intraabdominal implantations
Authors
Y. W. Novitsky
J. A. Cristiano
A. G. Harrell
W. Newcomb
J. H. Norton
K. W. Kercher
B. T. Heniford
Publication date
01-04-2008
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 4/2008
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-007-9737-3

Other articles of this Issue 4/2008

Surgical Endoscopy 4/2008 Go to the issue