Skip to main content
Top
Published in: Surgical Endoscopy 5/2004

01-05-2004 | Original article

Dexterity enhancement with robotic surgery

Authors: K. Moorthy, Y. Munz, A. Dosis, J. Hernandez, S. Martin, F. Bello, T. Rockall, A. Darzi

Published in: Surgical Endoscopy | Issue 5/2004

Login to get access

Abstract

Background

The aim of this study was to quantify the extent of dexterity enhancement in robotic surgery as compared to laparoscopic surgery.

Methods

Ten surgeons with varying laparoscopic suturing experience were asked to place three sutures on a suture pad. The sutures were placed laparoscopically, robotically with 2-D vision and robotically with 3-D vision. The da Vinci system’s Application Programming Interface (API) was used for positional data. A validated motion analysis system was used for data retrieval for the laparoscopic task. Custom software was developed for data analysis.

Results

Compared to laparoscopic suturing, when the task was undertaken robotically with 2-D vision there was a 20% reduction in the time taken but this was not significant (p = 0.07). There was a 55% reduction in the path traveled by the right hand (p = 0.01) and a 45% reduction in the path traveled by the left hand (p = 0.008). When the task was undertaken robotically with 3-D vision, there was a 40% reduction in the time taken (p = 0.01). There was a 70% reduction in the path traveled by right hand (p = 0.008) and a 55% reduction by the left hand (p = 0.08).

Conclusions

The presence of “wristed” instrumentation, tremor abolition, and motion scaling enhance dexterity by nearly 50% as compared to laparoscopic surgery. 3-D vision enhances dexterity by a further 10–15%. In addition, the presence of 3-D vision results in a 93% reduction in skills-based errors.
Literature
2.
go back to reference Beurger, R, Rember, M, Beckley, D 1997Laparoscopic instruments cause increased forearm fatigue: a subjective and objective comparison of open and laparoscopic techniques.Min Invasive Ther Allied63640 Beurger, R, Rember, M, Beckley, D 1997Laparoscopic instruments cause increased forearm fatigue: a subjective and objective comparison of open and laparoscopic techniques.Min Invasive Ther Allied63640
3.
go back to reference Buess, GF, Schurr, MO, Fischer, SC 2000Robotics and allied technologies in endoscopic surgery.Arch Surg132229235CrossRef Buess, GF, Schurr, MO, Fischer, SC 2000Robotics and allied technologies in endoscopic surgery.Arch Surg132229235CrossRef
4.
go back to reference Chan, A, Chung, S, Yim, A, Lau, J, Ng, E, Li, A 1997Comparison of two-dimensional vs three-dimensional camera systems in laparoscopic surgery.Surg Endosc11438440CrossRefPubMed Chan, A, Chung, S, Yim, A, Lau, J, Ng, E, Li, A 1997Comparison of two-dimensional vs three-dimensional camera systems in laparoscopic surgery.Surg Endosc11438440CrossRefPubMed
5.
go back to reference Cheah, WK, Lenzi, JE, So, J, Dong, F, Kum, CK, Goh, P 2001Evaluation of a head-mounted display (HMD) in the performance of a simulated laparoscopic task.Surg Endosc15990991PubMed Cheah, WK, Lenzi, JE, So, J, Dong, F, Kum, CK, Goh, P 2001Evaluation of a head-mounted display (HMD) in the performance of a simulated laparoscopic task.Surg Endosc15990991PubMed
6.
go back to reference Davies, B 2000A review of robotics in surgery.Proc Inst Mech Eng214129140CrossRef Davies, B 2000A review of robotics in surgery.Proc Inst Mech Eng214129140CrossRef
7.
go back to reference Dosis, A, Bello, F, Rockall, T, Munz, Y, Moorthy, K, Martin, S, Darzi, A 200xROVIMAS: a software package for assessing surgical skills using the da Vinci telemanipulator system.... Dosis, A, Bello, F, Rockall, T, Munz, Y, Moorthy, K, Martin, S, Darzi, A 200xROVIMAS: a software package for assessing surgical skills using the da Vinci telemanipulator system....
8.
go back to reference Felger, JE, Nifong, LW, Chitwood, WR,Jr 2002The evolution of and early experience with robot-assisted mitral valve surgery.Surg Laparosc Endosc Percutan Technol125863 Felger, JE, Nifong, LW, Chitwood, WR,Jr 2002The evolution of and early experience with robot-assisted mitral valve surgery.Surg Laparosc Endosc Percutan Technol125863
9.
go back to reference Gallagher, AG, Satava, RM 2002Virtual reality as a metric for the assessment of laparoscopic psychomotor skills.Learning curves and reliability measures. Surg Endosc1617461752CrossRef Gallagher, AG, Satava, RM 2002Virtual reality as a metric for the assessment of laparoscopic psychomotor skills.Learning curves and reliability measures. Surg Endosc1617461752CrossRef
10.
go back to reference Hanna, GB, Cuschieri, A 2000Influence of two-dimensional and three-dimensional imaging on endoscopic bowel suturing.World J Surg24444449PubMed Hanna, GB, Cuschieri, A 2000Influence of two-dimensional and three-dimensional imaging on endoscopic bowel suturing.World J Surg24444449PubMed
11.
go back to reference Hernandez, JD, Bann, SD, Munz, Y, Moorthy, K, Datta, V, Martin, S, Dosis, A, Bello, F, Darzi, A, Rockall, T 2002The learning curve of a simulated surgical task using the da Vinci telemanipulator system.Br J Surg891718CrossRef Hernandez, JD, Bann, SD, Munz, Y, Moorthy, K, Datta, V, Martin, S, Dosis, A, Bello, F, Darzi, A, Rockall, T 2002The learning curve of a simulated surgical task using the da Vinci telemanipulator system.Br J Surg891718CrossRef
12.
go back to reference Johns, DB, Brewer, JD, Soper, NJ 1996The influence of three-dimensional video systems on laparoscopic task performance.Surg Laparosc Endosc6191197CrossRefPubMed Johns, DB, Brewer, JD, Soper, NJ 1996The influence of three-dimensional video systems on laparoscopic task performance.Surg Laparosc Endosc6191197CrossRefPubMed
13.
go back to reference Kim, VB, Chapman, WHH, Albrecht, RJ, et al. 2002Early experience with Telemanipulative Robot-assisted laparoscopic cholecystectomy using da Vinci.Surg Laparosc Endosc Percutan Technol123340 Kim, VB, Chapman, WHH, Albrecht, RJ,  et al. 2002Early experience with Telemanipulative Robot-assisted laparoscopic cholecystectomy using da Vinci.Surg Laparosc Endosc Percutan Technol123340
14.
go back to reference Mueller, MD, Camartin, C, Dreher, E, Hanggi, W 1999Three-dimensional laparoscopy. Gadget or progress? A randomized trial on the efficacy of three-dimensional laparoscopy.Surg Endosc13469472CrossRefPubMed Mueller, MD, Camartin, C, Dreher, E, Hanggi, W 1999Three-dimensional laparoscopy. Gadget or progress? A randomized trial on the efficacy of three-dimensional laparoscopy.Surg Endosc13469472CrossRefPubMed
15.
go back to reference Munz, Y, Hernandez, H, Bann, S, Bello, F, Dosis, A, Martin, S, Moorthy, K, Rockall, T, Darzi, A 2002The advantages of 3D visualization in surgical performance with the Da-Vinci telemaniputation system.J Soc Laparosc Surg6264 Munz, Y, Hernandez, H, Bann, S, Bello, F, Dosis, A, Martin, S, Moorthy, K, Rockall, T, Darzi, A 2002The advantages of 3D visualization in surgical performance with the Da-Vinci telemaniputation system.J Soc Laparosc Surg6264
16.
go back to reference Shea, JA, Healey, MJ, Berlin, JA, Clarke, JR, Malet, PF, Staroscik, RN, Schwartz, JS, Williams, SV 1996Mortality and complications associated with laparoscopic cholecystectomy.A meta-analysis. Ann Surg224609620CrossRef Shea, JA, Healey, MJ, Berlin, JA, Clarke, JR, Malet, PF, Staroscik, RN, Schwartz, JS, Williams, SV 1996Mortality and complications associated with laparoscopic cholecystectomy.A meta-analysis. Ann Surg224609620CrossRef
17.
go back to reference Taffinder, N, Smith, S, Mair, J, et al. 1999Can a computer measure surgical precision? Reliability, validity and feasibility of the ICSAD.Surg Endosc1381CrossRef Taffinder, N, Smith, S, Mair, J,  et al. 1999Can a computer measure surgical precision? Reliability, validity and feasibility of the ICSAD.Surg Endosc1381CrossRef
18.
go back to reference Williams, LF, Chapman, WC, Bonau, RA, McGee, EC, Boyd, RW, Jacobs, JK 1993Comparison of laparoscopic cholecystectomy with open cholecystectomy in a single center.Am J Surg165459465PubMed Williams, LF, Chapman, WC, Bonau, RA, McGee, EC, Boyd, RW, Jacobs, JK 1993Comparison of laparoscopic cholecystectomy with open cholecystectomy in a single center.Am J Surg165459465PubMed
19.
go back to reference Yohannes, P, Rotariu, P, Pinto, P, Smith, AD, Lee, BR 2002Comparison of robotic versus laparoscopic skills: is there a difference in the learning curve?Urology603945CrossRef Yohannes, P, Rotariu, P, Pinto, P, Smith, AD, Lee, BR 2002Comparison of robotic versus laparoscopic skills: is there a difference in the learning curve?Urology603945CrossRef
Metadata
Title
Dexterity enhancement with robotic surgery
Authors
K. Moorthy
Y. Munz
A. Dosis
J. Hernandez
S. Martin
F. Bello
T. Rockall
A. Darzi
Publication date
01-05-2004
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 5/2004
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-003-8922-2

Other articles of this Issue 5/2004

Surgical Endoscopy 5/2004 Go to the issue