Skip to main content
Top
Published in: European Journal of Applied Physiology 8/2011

01-08-2011 | Original Article

Venous occlusion plethysmography versus Doppler ultrasound in the assessment of leg blood flow during calf exercise

Authors: Simon Green, R. Thorp, E. J. Reeder, J. Donnelly, G. Fordy

Published in: European Journal of Applied Physiology | Issue 8/2011

Login to get access

Abstract

This study explored the accuracy with which venous occlusion plethysmography (VOP) assesses the hyperaemic response during calf exercise. Using Doppler ultrasound (DU) as a criterion standard technique, we tested the hypotheses that leg blood flow during contraction is not greater than at rest and that VOP provides similar estimates of the hyperaemic response between contractions as DU. Eleven subjects performed several bouts of calf exercise across a wide range of forces (50–400 N ≅ 6–45%MVC). Each bout consisted of 2 min of intermittent contractions preceded and immediately followed by sustained (40 s) contractions. DU estimates of leg blood flow during the sustained contractions were never significantly greater (P > 0.05) than those measured at rest. Paired (DU and VOP) estimates of leg blood flow (n = 488) were obtained between intermittent contractions and ranged between ~50–900 ml min−1. There was a strong correlation between these DU and VOP estimates (Pearson r = 0.91; P < 0.05). Ordinary least products regression analysis, with VOP as the y variable, showed a relatively small proportional bias (slope = 0.942; CI = 0.938–0.946) and fixed bias (y intercept = −13.3 ml min−1; CI = −14.4 to −12.2 ml min−1) between the two measurement techniques. Since these small biases can be explained by the slight differences in vascular regions which the two techniques assess, these data suggest that VOP can accurately assess the hyperaemic response to exercise.
Literature
go back to reference Adiseshiah M, Barber RW, Szaz KF (1984) Measurement of regional lower limb blood flow in normal humans by inhalation of 133Xe. Eur J Nucl Med 9:379–381PubMedCrossRef Adiseshiah M, Barber RW, Szaz KF (1984) Measurement of regional lower limb blood flow in normal humans by inhalation of 133Xe. Eur J Nucl Med 9:379–381PubMedCrossRef
go back to reference Albracht K, Arampatzis A, Baltzopoulos V (2008) Assessment of muscle volume and physiological cross-sectional area of the human triceps surae muscle in vivo. J Biomech 41:2211–2218PubMedCrossRef Albracht K, Arampatzis A, Baltzopoulos V (2008) Assessment of muscle volume and physiological cross-sectional area of the human triceps surae muscle in vivo. J Biomech 41:2211–2218PubMedCrossRef
go back to reference Andersen P, Saltin B (1985) Maximal perfusion of skeletal muscle in man. J Physiol 366:233–249PubMed Andersen P, Saltin B (1985) Maximal perfusion of skeletal muscle in man. J Physiol 366:233–249PubMed
go back to reference Anderson JD, Epstein FH, Meyer CH, Hagspiel KD, Wang HK, Berr SS, Harthun NL, Weltman A, DiMaria JM, West AM, Kramer CM (2009) Multifactorial determinants of functional capacity in peripheral arterial disease uncoupling of calf muscle perfusion and metabolism. J Am Coll Cardiol 54:628–635PubMedCrossRef Anderson JD, Epstein FH, Meyer CH, Hagspiel KD, Wang HK, Berr SS, Harthun NL, Weltman A, DiMaria JM, West AM, Kramer CM (2009) Multifactorial determinants of functional capacity in peripheral arterial disease uncoupling of calf muscle perfusion and metabolism. J Am Coll Cardiol 54:628–635PubMedCrossRef
go back to reference Barcroft H, Millen JLE (1939) The blood flow through muscle during sustained contraction. J Physiol 97:17–31PubMed Barcroft H, Millen JLE (1939) The blood flow through muscle during sustained contraction. J Physiol 97:17–31PubMed
go back to reference Barker G, Green S, Askew C, Green A, Walker P (2001) Effect of propionyl-l-carnitine on exercise performance in peripheral arterial disease. Med Sci Sports Exerc 33:1415–1422PubMedCrossRef Barker G, Green S, Askew C, Green A, Walker P (2001) Effect of propionyl-l-carnitine on exercise performance in peripheral arterial disease. Med Sci Sports Exerc 33:1415–1422PubMedCrossRef
go back to reference Barker GA, Green S, Green AA, Walker PJ (2004) Walking performance, oxygen uptake kinetics and resting muscle pyruvate dehydrogenase complex activity in peripheral arterial disease. Clin Sci 106:241–249PubMedCrossRef Barker GA, Green S, Green AA, Walker PJ (2004) Walking performance, oxygen uptake kinetics and resting muscle pyruvate dehydrogenase complex activity in peripheral arterial disease. Clin Sci 106:241–249PubMedCrossRef
go back to reference Bauer TA, Regensteiner JG, Brass EP, Hiatt WR (1999) Oxygen uptake kinetics during exercise are slowed in patients with peripheral arterial disease. J Appl Physiol 87:809–816PubMed Bauer TA, Regensteiner JG, Brass EP, Hiatt WR (1999) Oxygen uptake kinetics during exercise are slowed in patients with peripheral arterial disease. J Appl Physiol 87:809–816PubMed
go back to reference Bernink PJLM, Lubbers J, Barendsen GJ, van den Berg J (1982) Blood flow in the calf during and after exercise: measurements with Doppler ultrasound and venous occlusion plethysmography in healthy subjects and in patients with arterial occlusive disease. Angiology 33:146–160PubMedCrossRef Bernink PJLM, Lubbers J, Barendsen GJ, van den Berg J (1982) Blood flow in the calf during and after exercise: measurements with Doppler ultrasound and venous occlusion plethysmography in healthy subjects and in patients with arterial occlusive disease. Angiology 33:146–160PubMedCrossRef
go back to reference Boushel R, Langberg H, Green S, Skovgaard D, Bulow J, Kjaer M (2000) Blood flow and oxygenation in peritendinous tissue and calf muscle during dynamic exercise in humans. J Physiol 524.1:305–313CrossRef Boushel R, Langberg H, Green S, Skovgaard D, Bulow J, Kjaer M (2000) Blood flow and oxygenation in peritendinous tissue and calf muscle during dynamic exercise in humans. J Physiol 524.1:305–313CrossRef
go back to reference Boyd J, Buick J, Green S (2006) A second order accurate lattice Boltzmann non-Newtonian flow model. J Phys A Math Gen 39:14241–14247CrossRef Boyd J, Buick J, Green S (2006) A second order accurate lattice Boltzmann non-Newtonian flow model. J Phys A Math Gen 39:14241–14247CrossRef
go back to reference Bylund-Fellenius AC, Walker PM, Elander A, Holm S, Schersten T (1981) Energy metabolism in relation to oxygen partial pressure in human skeletal muscle during exercise. Biochem J 200:247–255PubMed Bylund-Fellenius AC, Walker PM, Elander A, Holm S, Schersten T (1981) Energy metabolism in relation to oxygen partial pressure in human skeletal muscle during exercise. Biochem J 200:247–255PubMed
go back to reference Bystrom S, Jensen B, Jensen-Urstad M, Lindblad LE, Kilbom A (1998) Ultrasound-Doppler technique for monitoring blood flow in the brachial artery compared with occlusion plethysmography of the forearm. Scand J Clin Lab Invest 58:569–576PubMedCrossRef Bystrom S, Jensen B, Jensen-Urstad M, Lindblad LE, Kilbom A (1998) Ultrasound-Doppler technique for monitoring blood flow in the brachial artery compared with occlusion plethysmography of the forearm. Scand J Clin Lab Invest 58:569–576PubMedCrossRef
go back to reference Egana M, Green S (2005) Effect of body tilt on calf muscle performance and blood flow in humans. J Appl Physiol 98:2249–2258PubMedCrossRef Egana M, Green S (2005) Effect of body tilt on calf muscle performance and blood flow in humans. J Appl Physiol 98:2249–2258PubMedCrossRef
go back to reference Gaffney FA, Sjogaard G, Saltin B (1990) Cardiovascular and metabolic responses to static contraction in man. Acta Physiol Scand 138:249–258PubMedCrossRef Gaffney FA, Sjogaard G, Saltin B (1990) Cardiovascular and metabolic responses to static contraction in man. Acta Physiol Scand 138:249–258PubMedCrossRef
go back to reference Gonzalez-Alonso J, Mortensen SP, Dawson EA, Secher NH, Damsgaard R (2006) Erythrocytes and the regulation of human skeletal muscle blood flow and oxygen delivery: role of erythrocyte count and oxygenation state of haemoglobin. J Physiol 572:295–305PubMed Gonzalez-Alonso J, Mortensen SP, Dawson EA, Secher NH, Damsgaard R (2006) Erythrocytes and the regulation of human skeletal muscle blood flow and oxygen delivery: role of erythrocyte count and oxygenation state of haemoglobin. J Physiol 572:295–305PubMed
go back to reference Green S (2002) Haemodynamic limitations and exercise performance in peripheral arterial disease. Clin Physiol Funct Imaging 22:81–91PubMedCrossRef Green S (2002) Haemodynamic limitations and exercise performance in peripheral arterial disease. Clin Physiol Funct Imaging 22:81–91PubMedCrossRef
go back to reference Heinonen I, Nesterov SV, Kemppainen J, Nuutila P, Knuuti J, Laitio R, Kjaer M, Boushel R, Kalliokoski KK (2007) Role of adenosine in regulating the heterogeneity of skeletal muscle blood flow during exercise in humans. J Appl Physiol 103:2042–2048PubMedCrossRef Heinonen I, Nesterov SV, Kemppainen J, Nuutila P, Knuuti J, Laitio R, Kjaer M, Boushel R, Kalliokoski KK (2007) Role of adenosine in regulating the heterogeneity of skeletal muscle blood flow during exercise in humans. J Appl Physiol 103:2042–2048PubMedCrossRef
go back to reference Hiatt WR, Huang SY, Regensteiner JG, Micco AJ, Ishimoto G, Manco-Johnson M, Drose J, Reeves JT (1989) Venous occlusion plethysmography reduces arterial diameter and flow velocity. J Appl Physiol 66:2239–2244PubMed Hiatt WR, Huang SY, Regensteiner JG, Micco AJ, Ishimoto G, Manco-Johnson M, Drose J, Reeves JT (1989) Venous occlusion plethysmography reduces arterial diameter and flow velocity. J Appl Physiol 66:2239–2244PubMed
go back to reference Hiatt WR, Brass EP, Green S (2004) Skeletal muscle metabolic changes in peripheral arterial disease contribute to exercise intolerance: a point-counterpoint discussion. Vasc Med 9:293–301PubMedCrossRef Hiatt WR, Brass EP, Green S (2004) Skeletal muscle metabolic changes in peripheral arterial disease contribute to exercise intolerance: a point-counterpoint discussion. Vasc Med 9:293–301PubMedCrossRef
go back to reference Hughson RL, Tschakovsky ME, Houston ME (2001) Regulation of oxygen consumption at the onset of exercise. Exerc Sport Sci Rev 29:129–133PubMedCrossRef Hughson RL, Tschakovsky ME, Houston ME (2001) Regulation of oxygen consumption at the onset of exercise. Exerc Sport Sci Rev 29:129–133PubMedCrossRef
go back to reference Jorfeldt L, Rutberg H (1990) Comparison of dye-dilution and plethysmographic blood flow measurements: an evaluation of the influence of invasive techniques on blood flow and on arterial and femoral venous substrate variables in man. Clin Sci 79:81–87PubMed Jorfeldt L, Rutberg H (1990) Comparison of dye-dilution and plethysmographic blood flow measurements: an evaluation of the influence of invasive techniques on blood flow and on arterial and femoral venous substrate variables in man. Clin Sci 79:81–87PubMed
go back to reference Jorfeldt L, Vedung T, Forsstrom E, Henriksson J (2003) Influence of leg position and environmental temperature on segmental volume expansion during venous occlusion plethysmography. Clin Sci 104:599–605PubMedCrossRef Jorfeldt L, Vedung T, Forsstrom E, Henriksson J (2003) Influence of leg position and environmental temperature on segmental volume expansion during venous occlusion plethysmography. Clin Sci 104:599–605PubMedCrossRef
go back to reference Joyner MJ, Dietz NM, Shepherd JT (2001) From Belfast to Mayo and beyond: the use and future of plethysmography to study blood flow in human limbs. J Appl Physiol 91:2431–2441PubMed Joyner MJ, Dietz NM, Shepherd JT (2001) From Belfast to Mayo and beyond: the use and future of plethysmography to study blood flow in human limbs. J Appl Physiol 91:2431–2441PubMed
go back to reference Kagaya A, Homma S (1997) Brachial arterial blood flow during static handgrip exercise of short duration at varying intensities studied by a Doppler ultrasound method. Acta Physiol Scand 160:257–265PubMedCrossRef Kagaya A, Homma S (1997) Brachial arterial blood flow during static handgrip exercise of short duration at varying intensities studied by a Doppler ultrasound method. Acta Physiol Scand 160:257–265PubMedCrossRef
go back to reference Kalliokoski KK, Laaksonen MS, Takala TO, Knuuti J, Nuutila P (2003) Muscle oxygen extraction and perfusion heterogeneity during continuous and intermittent static exercise. J Appl Physiol 94:953–958PubMed Kalliokoski KK, Laaksonen MS, Takala TO, Knuuti J, Nuutila P (2003) Muscle oxygen extraction and perfusion heterogeneity during continuous and intermittent static exercise. J Appl Physiol 94:953–958PubMed
go back to reference Kaulesar Sukul DMKS, den Hoed PT, Johannes EJ, van Dolder R, Benda E (1993) Direct and indirect methods for the quantification of leg volume: comparison between water displacement volumetry, the disk model method and the frustum sign model method, using the correlation coefficient and the limits of agreement. J Biomed Eng 15:477–480PubMedCrossRef Kaulesar Sukul DMKS, den Hoed PT, Johannes EJ, van Dolder R, Benda E (1993) Direct and indirect methods for the quantification of leg volume: comparison between water displacement volumetry, the disk model method and the frustum sign model method, using the correlation coefficient and the limits of agreement. J Biomed Eng 15:477–480PubMedCrossRef
go back to reference Knox R, Cramer M, Fell G, Breslau P, Beach K, Strandness DE (1982) Pitfall of venous occlusion plethysmography. Angiology 33:268–276PubMedCrossRef Knox R, Cramer M, Fell G, Breslau P, Beach K, Strandness DE (1982) Pitfall of venous occlusion plethysmography. Angiology 33:268–276PubMedCrossRef
go back to reference Koskolou M, Calbet JA, Radegran G, Roach RC (1997) Hypoxia and the cardiovascular response to dynamic knee-extensor exercise. Am J Physiol 272:H2655–H2663PubMed Koskolou M, Calbet JA, Radegran G, Roach RC (1997) Hypoxia and the cardiovascular response to dynamic knee-extensor exercise. Am J Physiol 272:H2655–H2663PubMed
go back to reference Lassen NA, Kampp M (1965) Calf muscle blood flow during walking studied by the Xe133 method in normals and in patients with intermittent claudication. Scand J Clin Lab Invest 17:447–453PubMed Lassen NA, Kampp M (1965) Calf muscle blood flow during walking studied by the Xe133 method in normals and in patients with intermittent claudication. Scand J Clin Lab Invest 17:447–453PubMed
go back to reference Longhurst J, Capone RJ, Mason DT, Zelis R (1974) Comparison of blood flow measured by plethysmograph and flowmeter during steady state forearm exercise. Circulation 49:535–540PubMed Longhurst J, Capone RJ, Mason DT, Zelis R (1974) Comparison of blood flow measured by plethysmograph and flowmeter during steady state forearm exercise. Circulation 49:535–540PubMed
go back to reference Lubbers J, Bernink PJLM, Barendsen GJ, vab den Berg JW (1979) A continuous wave Doppler velocimeter for monitoring blood flow in the popliteal artery, compared with venous occlusion plethysmography of the calf. Pflugers Arch 382:241–248PubMedCrossRef Lubbers J, Bernink PJLM, Barendsen GJ, vab den Berg JW (1979) A continuous wave Doppler velocimeter for monitoring blood flow in the popliteal artery, compared with venous occlusion plethysmography of the calf. Pflugers Arch 382:241–248PubMedCrossRef
go back to reference Pallares LCM, Deane CR, Baudouin SV, Evans TW (1994) Strain gauge plethysmography and Doppler ultrasound in the measurement of limb blood flow. Eur J Clin Inv 24:279–286CrossRef Pallares LCM, Deane CR, Baudouin SV, Evans TW (1994) Strain gauge plethysmography and Doppler ultrasound in the measurement of limb blood flow. Eur J Clin Inv 24:279–286CrossRef
go back to reference Pernow B, Saltin B, Wahren J, Cronestrand R, Ekestrom S (1975) Leg blood flow and muscle metabolism in occlusive arterial disease of the leg before and after reconstructive surgery. Clin Sci Mol Med 49:265–275PubMed Pernow B, Saltin B, Wahren J, Cronestrand R, Ekestrom S (1975) Leg blood flow and muscle metabolism in occlusive arterial disease of the leg before and after reconstructive surgery. Clin Sci Mol Med 49:265–275PubMed
go back to reference Radegran G (1997) Ultrasound Doppler estimates of femoral artery blood flow during dynamic knee extensor exercise in humans. J Appl Physiol 83:1383–1388PubMed Radegran G (1997) Ultrasound Doppler estimates of femoral artery blood flow during dynamic knee extensor exercise in humans. J Appl Physiol 83:1383–1388PubMed
go back to reference Radegran G (1999) Limb and skeletal muscle blood flow measurements at rest and during exercise in human subjects. Proc Nutr Soc 58:887–898PubMedCrossRef Radegran G (1999) Limb and skeletal muscle blood flow measurements at rest and during exercise in human subjects. Proc Nutr Soc 58:887–898PubMedCrossRef
go back to reference Radegran G, Saltin B (1998) Muscle blood flow at onset of dynamic exercise in humans. Am J Physiol 43:H314–H322 Radegran G, Saltin B (1998) Muscle blood flow at onset of dynamic exercise in humans. Am J Physiol 43:H314–H322
go back to reference Richardson D (1981) Blood flow response of human calf muscles to static contractions at various percentages of MVC. J Appl Physiol 51:929–933PubMed Richardson D (1981) Blood flow response of human calf muscles to static contractions at various percentages of MVC. J Appl Physiol 51:929–933PubMed
go back to reference Richardson D, Shewchuk R (1980) Effects of contraction force and frequency on postexercise hyperemia in human calf muscles. J Appl Physiol 49:649–654PubMed Richardson D, Shewchuk R (1980) Effects of contraction force and frequency on postexercise hyperemia in human calf muscles. J Appl Physiol 49:649–654PubMed
go back to reference Roberts DH, Tsao Y, Breckenridge AM (1986) The reproducibility of limb blood flow measurements in human volunteers at rest and after exercise by using mercury-in-Silastic strain gauge plethysmography under standardised conditions. Clin Sci 70:635–638PubMed Roberts DH, Tsao Y, Breckenridge AM (1986) The reproducibility of limb blood flow measurements in human volunteers at rest and after exercise by using mercury-in-Silastic strain gauge plethysmography under standardised conditions. Clin Sci 70:635–638PubMed
go back to reference Saltin B (2007) Exercise hyperaemia: magnitude and aspects on regulation in humans. J Physiol 583.3:819–823CrossRef Saltin B (2007) Exercise hyperaemia: magnitude and aspects on regulation in humans. J Physiol 583.3:819–823CrossRef
go back to reference Saunders NR, Pyke KE, Tschakovsky ME (2005) Dynamic response characteristics of local muscle blood flow regulatory mechanisms in human forearm exercise. J Appl Physiol 98:1286–1296PubMedCrossRef Saunders NR, Pyke KE, Tschakovsky ME (2005) Dynamic response characteristics of local muscle blood flow regulatory mechanisms in human forearm exercise. J Appl Physiol 98:1286–1296PubMedCrossRef
go back to reference Sorlie D, Myhre K (1978) Lower leg blood flow in intermittent claudication. Scand J Clin Lab Invest 38:171–179PubMedCrossRef Sorlie D, Myhre K (1978) Lower leg blood flow in intermittent claudication. Scand J Clin Lab Invest 38:171–179PubMedCrossRef
go back to reference Tschakovsky ME, Shoemaker JK, Hughson RL (1995) Beat-by-beat forearm blood flow with Doppler ultrasound and strain-gauge plethysmography. J Appl Physiol 79:713–719PubMed Tschakovsky ME, Shoemaker JK, Hughson RL (1995) Beat-by-beat forearm blood flow with Doppler ultrasound and strain-gauge plethysmography. J Appl Physiol 79:713–719PubMed
go back to reference Tschakovsky ME, Saunders NR, Webb KA, O’Donnell DE (2006) Muscle blood flow dynamics at exercise onset: Do the limbs differ? Med Sci Sports Exerc 38:1811–1818PubMedCrossRef Tschakovsky ME, Saunders NR, Webb KA, O’Donnell DE (2006) Muscle blood flow dynamics at exercise onset: Do the limbs differ? Med Sci Sports Exerc 38:1811–1818PubMedCrossRef
go back to reference Walloe L, Wesche J (1988) Time course and magnitude of blood flow changes in the human quadriceps muscles during and following rhythmic exercise. J Physiol 405:257–273PubMed Walloe L, Wesche J (1988) Time course and magnitude of blood flow changes in the human quadriceps muscles during and following rhythmic exercise. J Physiol 405:257–273PubMed
go back to reference Whitney RJ (1953) The measurement of volume changes in human limbs. J Physiol 121:1–27PubMed Whitney RJ (1953) The measurement of volume changes in human limbs. J Physiol 121:1–27PubMed
Metadata
Title
Venous occlusion plethysmography versus Doppler ultrasound in the assessment of leg blood flow during calf exercise
Authors
Simon Green
R. Thorp
E. J. Reeder
J. Donnelly
G. Fordy
Publication date
01-08-2011
Publisher
Springer-Verlag
Published in
European Journal of Applied Physiology / Issue 8/2011
Print ISSN: 1439-6319
Electronic ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-010-1819-6

Other articles of this Issue 8/2011

European Journal of Applied Physiology 8/2011 Go to the issue