Skip to main content
Top
Published in: European Journal of Applied Physiology 5/2011

01-05-2011 | Original Article

Muscle oxygenation of vastus lateralis and medialis muscles during alternating and pulsed current electrical stimulation

Authors: Abdulaziz Aldayel, Makii Muthalib, Marc Jubeau, Michael McGuigan, Kazunori Nosaka

Published in: European Journal of Applied Physiology | Issue 5/2011

Login to get access

Abstract

This study compared between alternating and pulsed current electrical muscle stimulation (EMS) for muscle oxygenation and blood volume during isometric contractions. Nine healthy men (23–48 years) received alternating current EMS (2500 Hz) modulated at 75 Hz on the knee extensors of one leg, and pulsed current EMS (75 Hz) for the other leg separated by 2 weeks in a randomised, counter-balanced order. Pulse duration (400 μs), on–off ratio (5–15 s) and other stimulation parameters were matched between conditions and 30 isometric contractions were induced at the knee joint angle of 100° (0° full extension). Changes in tissue oxygenation index (∆TOI) and total hemoglobin volume (∆tHb) of vastus lateralis and medialis muscles over 30 contractions were assessed by a near-infrared spectroscopy, and were compared between conditions by a two-way repeated measures ANOVA. Peak torque produced during EMS increased over 30 contractions in response to the increase in the stimulation intensity for pulsed current, but not for the alternating current EMS. The torque during each isometric contraction was less stable in alternating than pulsed current EMS. The changes in ∆TOI amplitude during relaxation phases and ∆tHb amplitude were not significantly different between conditions. However, the decreases in ∆TOI amplitude during contraction phases from baseline were significantly (P < 0.05) greater for the pulsed current than alternating current from the 18th contraction (−15.6 ± 2.3 vs. −8.9 ± 1.8%) to 30th contraction (−10.7 ± 1.8 vs. −4.8 ± 1.5%). These results suggest that the muscles were less activated in the alternating current EMS when compared with the pulsed current EMS.
Literature
go back to reference Binder-Macleod SA, Halden EE, Jungles KA (1995) Effects of stimulation intensity on the physiological responses of human motor units. Med Sci Sports Exerc 27:556–565PubMed Binder-Macleod SA, Halden EE, Jungles KA (1995) Effects of stimulation intensity on the physiological responses of human motor units. Med Sci Sports Exerc 27:556–565PubMed
go back to reference Cettolo V, Ferrari M, Biasini V, Quaresima V (2007) Vastus lateralis O2 desaturation in response to fast and short maximal contraction. Med Sci Sports Exerc 39:1949–1959PubMedCrossRef Cettolo V, Ferrari M, Biasini V, Quaresima V (2007) Vastus lateralis O2 desaturation in response to fast and short maximal contraction. Med Sci Sports Exerc 39:1949–1959PubMedCrossRef
go back to reference Chance B, Nioka S, Kent J, McCully K, Fountain M, Greenfeld R, Holtom G (1988) Time-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscle. Anal Biochem 174:698–707PubMedCrossRef Chance B, Nioka S, Kent J, McCully K, Fountain M, Greenfeld R, Holtom G (1988) Time-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscle. Anal Biochem 174:698–707PubMedCrossRef
go back to reference Felici F, Quaresima V, Fattorini L, Sbriccoli P, Filligoi GC, Ferrari M (2009) Biceps brachii myoelectric and oxygenation changes during static and sinusoidal isometric exercises. J Electromyogr Kinesiol 19:e1–e11PubMedCrossRef Felici F, Quaresima V, Fattorini L, Sbriccoli P, Filligoi GC, Ferrari M (2009) Biceps brachii myoelectric and oxygenation changes during static and sinusoidal isometric exercises. J Electromyogr Kinesiol 19:e1–e11PubMedCrossRef
go back to reference Gondin J, Giannesini B, Vilmen C, Dalmasso C, le Fur Y, Cozzone PJ, Bendahan D (2010) Effects of stimulation frequency and pulse duration on fatigue and metabolic cost during a single bout of neuromuscular electrical stimulation. Muscle Nerve 41:667–678PubMed Gondin J, Giannesini B, Vilmen C, Dalmasso C, le Fur Y, Cozzone PJ, Bendahan D (2010) Effects of stimulation frequency and pulse duration on fatigue and metabolic cost during a single bout of neuromuscular electrical stimulation. Muscle Nerve 41:667–678PubMed
go back to reference Gorgey AS, Mahoney E, Kendall T, Dudley GA (2006) Effects of neuromuscular electrical stimulation parameters on specific tension. Eur J Appl Physiol 97:737–744PubMedCrossRef Gorgey AS, Mahoney E, Kendall T, Dudley GA (2006) Effects of neuromuscular electrical stimulation parameters on specific tension. Eur J Appl Physiol 97:737–744PubMedCrossRef
go back to reference Grimby G, Wigerstad-Lossing I (1989) Comparison of high- and low-frequency muscle stimulators. Arch Phys Med Rehabil 70:835–838PubMed Grimby G, Wigerstad-Lossing I (1989) Comparison of high- and low-frequency muscle stimulators. Arch Phys Med Rehabil 70:835–838PubMed
go back to reference Hamaoka T, McCully KK, Quaresima V, Yamamoto K, Chance B (2007) Near-infrared spectroscopy/imaging for monitoring muscle oxygenation and oxidative metabolism in healthy and diseased humans. J Biomed Opt 12:062105PubMedCrossRef Hamaoka T, McCully KK, Quaresima V, Yamamoto K, Chance B (2007) Near-infrared spectroscopy/imaging for monitoring muscle oxygenation and oxidative metabolism in healthy and diseased humans. J Biomed Opt 12:062105PubMedCrossRef
go back to reference Hampson NB, Piantadosi CA (1988) Near infrared monitoring of human skeletal muscle oxygenation during forearm ischemia. J Appl Physiol 64:2449–2457PubMed Hampson NB, Piantadosi CA (1988) Near infrared monitoring of human skeletal muscle oxygenation during forearm ischemia. J Appl Physiol 64:2449–2457PubMed
go back to reference Holcomb WR, Golestani S, Hill S (2000) A comparison of knee-extension torque production with biphasic versus Russian current. J Sport Rehabil 9:229–239 Holcomb WR, Golestani S, Hill S (2000) A comparison of knee-extension torque production with biphasic versus Russian current. J Sport Rehabil 9:229–239
go back to reference Jubeau M, Sartorio A, Marinone PG, Agosti F, Van Hoecke J, Nosaka K, Maffiuletti NA (2008) Comparison between voluntary and stimulated contractions of the quadriceps femoris for growth hormone response and muscle damage. J Appl Physiol 104:75–81PubMedCrossRef Jubeau M, Sartorio A, Marinone PG, Agosti F, Van Hoecke J, Nosaka K, Maffiuletti NA (2008) Comparison between voluntary and stimulated contractions of the quadriceps femoris for growth hormone response and muscle damage. J Appl Physiol 104:75–81PubMedCrossRef
go back to reference Kooistra RD, de Ruiter CJ, de Haan A (2008) Knee angle-dependent oxygen consumption of human quadriceps muscles during maximal voluntary and electrically evoked contractions. Eur J Appl Physiol 102:233–242PubMedCrossRef Kooistra RD, de Ruiter CJ, de Haan A (2008) Knee angle-dependent oxygen consumption of human quadriceps muscles during maximal voluntary and electrically evoked contractions. Eur J Appl Physiol 102:233–242PubMedCrossRef
go back to reference Laufer Y, Elboim M (2008) Effect of burst frequency and duration of kilohertz-frequency alternating currents and of low-frequency pulsed currents on strength of contraction, muscle fatigue, and perceived discomfort. Phys Ther 88:1167–1176PubMedCrossRef Laufer Y, Elboim M (2008) Effect of burst frequency and duration of kilohertz-frequency alternating currents and of low-frequency pulsed currents on strength of contraction, muscle fatigue, and perceived discomfort. Phys Ther 88:1167–1176PubMedCrossRef
go back to reference Laufer Y, Ries JD, Leininger PM, Alon G (2001) Quadriceps femoris muscle torques and fatigue generated by neuromuscular electrical stimulation with three different waveforms. Phys Ther 81:1307–1316PubMed Laufer Y, Ries JD, Leininger PM, Alon G (2001) Quadriceps femoris muscle torques and fatigue generated by neuromuscular electrical stimulation with three different waveforms. Phys Ther 81:1307–1316PubMed
go back to reference Lyons CL, Robb JB, Irrgang JJ, Fitzgerald GK (2005) Differences in quadriceps femoris muscle torque when using a clinical electrical stimulator versus a portable electrical stimulator. Phys Ther 85:44–51PubMed Lyons CL, Robb JB, Irrgang JJ, Fitzgerald GK (2005) Differences in quadriceps femoris muscle torque when using a clinical electrical stimulator versus a portable electrical stimulator. Phys Ther 85:44–51PubMed
go back to reference Mackel RG, Brink EE (1995) Accommodation in single human nerve fibers in vivo. Muscle Nerve 18:469–471PubMedCrossRef Mackel RG, Brink EE (1995) Accommodation in single human nerve fibers in vivo. Muscle Nerve 18:469–471PubMedCrossRef
go back to reference McCully KK, Hamaoka T (2000) Near-infrared spectroscopy: what can it tell us about oxygen saturation in skeletal muscle? Exerc Sport Sci Rev 28:123–127PubMed McCully KK, Hamaoka T (2000) Near-infrared spectroscopy: what can it tell us about oxygen saturation in skeletal muscle? Exerc Sport Sci Rev 28:123–127PubMed
go back to reference Owens J, Malone TR (1983) Treatment parameters of high frequency electrical stimulation as established on the Electro-Stim 180. J Orthop Sports Phys Ther 4:162–168PubMed Owens J, Malone TR (1983) Treatment parameters of high frequency electrical stimulation as established on the Electro-Stim 180. J Orthop Sports Phys Ther 4:162–168PubMed
go back to reference Quaresima V, Lepanto R, Ferrari M (2003) The use of near infrared spectroscopy in sports medicine. J Sports Med Phys Fitness 43:1–13PubMed Quaresima V, Lepanto R, Ferrari M (2003) The use of near infrared spectroscopy in sports medicine. J Sports Med Phys Fitness 43:1–13PubMed
go back to reference Robertson V, Ward AR, Low J, Reed A (2006) Electrotherapy explained: principles and practice. Butterworth-Heinemann Ltd, London Robertson V, Ward AR, Low J, Reed A (2006) Electrotherapy explained: principles and practice. Butterworth-Heinemann Ltd, London
go back to reference Rooney JG, Currier DP, Nitz AJ (1992) Effect of variation in the burst and carrier frequency modes of neuromuscular electrical stimulation on pain perception of healthy subjects. Phys Ther 72:800–806 discussion 807–809PubMed Rooney JG, Currier DP, Nitz AJ (1992) Effect of variation in the burst and carrier frequency modes of neuromuscular electrical stimulation on pain perception of healthy subjects. Phys Ther 72:800–806 discussion 807–809PubMed
go back to reference Sadamoto T, Bonde-Petersen F, Suzuki Y (1983) Skeletal muscle tension, flow, pressure, and EMG during sustained isometric contractions in humans. Eur J Appl Physiol Occup Physiol 51:395–408PubMedCrossRef Sadamoto T, Bonde-Petersen F, Suzuki Y (1983) Skeletal muscle tension, flow, pressure, and EMG during sustained isometric contractions in humans. Eur J Appl Physiol Occup Physiol 51:395–408PubMedCrossRef
go back to reference Selkowitz DM (1985) Improvement in isometric strength of the quadriceps femoris muscle after training with electrical stimulation. Phys Ther 65:186–196PubMed Selkowitz DM (1985) Improvement in isometric strength of the quadriceps femoris muscle after training with electrical stimulation. Phys Ther 65:186–196PubMed
go back to reference Sieck GC, Prakash YS (1995) Fatigue at the neuromuscular junction. Branch point vs. presynaptic vs. postsynaptic mechanisms. Adv Exp Med Biol 384:83–100PubMed Sieck GC, Prakash YS (1995) Fatigue at the neuromuscular junction. Branch point vs. presynaptic vs. postsynaptic mechanisms. Adv Exp Med Biol 384:83–100PubMed
go back to reference Snyder-Mackler L, Garrett M, Roberts M (1989) A comparison of torque generating capabilities of three different electrical stimulating currents. J Orthop Sports Phys Ther 10:297–301PubMed Snyder-Mackler L, Garrett M, Roberts M (1989) A comparison of torque generating capabilities of three different electrical stimulating currents. J Orthop Sports Phys Ther 10:297–301PubMed
go back to reference Snyder-Mackler L, Delitto A, Stralka SW, Bailey SL (1994) Use of electrical stimulation to enhance recovery of quadriceps femoris muscle force production in patients following anterior cruciate ligament reconstruction. Phys Ther 74:901–907PubMed Snyder-Mackler L, Delitto A, Stralka SW, Bailey SL (1994) Use of electrical stimulation to enhance recovery of quadriceps femoris muscle force production in patients following anterior cruciate ligament reconstruction. Phys Ther 74:901–907PubMed
go back to reference Stefanovska A, Vodovnik L (1985) Change in muscle force following electrical stimulation. Dependence on stimulation waveform and frequency. Scand J Rehabil Med 17:141–146PubMed Stefanovska A, Vodovnik L (1985) Change in muscle force following electrical stimulation. Dependence on stimulation waveform and frequency. Scand J Rehabil Med 17:141–146PubMed
go back to reference Suzuki S, Takasaki S, Ozaki T, Kobayashi Y (1999) Tissue oxygenation monitor using NIR spatially resolved spectroscopy. In: Britton C, Robert RA, Bruce JT (eds) SPIE, pp 582–592 Suzuki S, Takasaki S, Ozaki T, Kobayashi Y (1999) Tissue oxygenation monitor using NIR spatially resolved spectroscopy. In: Britton C, Robert RA, Bruce JT (eds) SPIE, pp 582–592
go back to reference Ward AR (2009) Electrical stimulation using kilohertz-frequency alternating current. Phys Ther 89:181–190PubMedCrossRef Ward AR (2009) Electrical stimulation using kilohertz-frequency alternating current. Phys Ther 89:181–190PubMedCrossRef
go back to reference Ward AR, Robertson VJ (2000) The variation in fatigue rate with frequency using kHz frequency alternating current. Med Eng Phys 22:637–646PubMedCrossRef Ward AR, Robertson VJ (2000) The variation in fatigue rate with frequency using kHz frequency alternating current. Med Eng Phys 22:637–646PubMedCrossRef
go back to reference Ward AR, Shkuratova N (2002) Russian electrical stimulation: the early experiments. Phys Ther 82:1019–1030PubMed Ward AR, Shkuratova N (2002) Russian electrical stimulation: the early experiments. Phys Ther 82:1019–1030PubMed
Metadata
Title
Muscle oxygenation of vastus lateralis and medialis muscles during alternating and pulsed current electrical stimulation
Authors
Abdulaziz Aldayel
Makii Muthalib
Marc Jubeau
Michael McGuigan
Kazunori Nosaka
Publication date
01-05-2011
Publisher
Springer-Verlag
Published in
European Journal of Applied Physiology / Issue 5/2011
Print ISSN: 1439-6319
Electronic ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-010-1699-9

Other articles of this Issue 5/2011

European Journal of Applied Physiology 5/2011 Go to the issue