Skip to main content
Top
Published in: European Journal of Applied Physiology 5/2011

01-05-2011 | Short Communication

Validation of the SenseWear Armband at high intensity exercise

Authors: Clemens Drenowatz, Joey C. Eisenmann

Published in: European Journal of Applied Physiology | Issue 5/2011

Login to get access

Abstract

The SenseWear Armband (SWA) has been shown to be a valid and practical tool to assess energy expenditure during habitual physical activity. However, previous studies have focused on low-to-moderate intensity activities. The purpose of this study was to assess the validity of the SWA during high intensity exercise. Twenty (ten males, ten females) endurance trained subjects, 24.3 (±2.8) years of age, performed three 10-min treadmill runs at 65, 75, and 85% of their VO2max each and also ran outside for 30 min at their preferred speed. Energy expenditure was measured with the SWA (software version 6.1) and a portable indirect calorimetry system (Jaeger Oxycon Mobile®). The SWA showed a ceiling effect around an intensity of ten METs. Since all subjects exceeded that intensity range during the exercise trials, the SWA significantly underestimated energy expenditure at high intensities. The intra-individual correlations between MET values calculated by the SWA and values derived from the Oxycon, however, were significant for all but two subjects (r = 0.390–0.933, mean = 0.66 ± 0.25). While providing accurate results for energy expenditure during low-to-moderate intensity physical activities, the SWA does not provide accurate estimates of energy expenditure at high intensity levels. The threshold for accurate measurements seems to be around an intensity of ten METs.
Literature
go back to reference Ainslie P, Reilly T, Westerterp K (2003) Estimating human energy expenditure: a review of techniques with particular reference to doubly labelled water. Sports Med 33(9):683–698PubMedCrossRef Ainslie P, Reilly T, Westerterp K (2003) Estimating human energy expenditure: a review of techniques with particular reference to doubly labelled water. Sports Med 33(9):683–698PubMedCrossRef
go back to reference Beashel P, Taylor J (eds) (1996) Advanced studies in physical education and sports. Nelson Thornes, Cheltenham Beashel P, Taylor J (eds) (1996) Advanced studies in physical education and sports. Nelson Thornes, Cheltenham
go back to reference Calabró MA, Welk GJ, Eisenmann JC (2009) Validation of the SenseWear Pro Armband algorithms in children. Med Sci Sports Exerc 41:1714–1720PubMedCrossRef Calabró MA, Welk GJ, Eisenmann JC (2009) Validation of the SenseWear Pro Armband algorithms in children. Med Sci Sports Exerc 41:1714–1720PubMedCrossRef
go back to reference Corder K, Brage S, Ekelund U (2007) Accelerometers and pedometers: methodology and clinical application. Curr Opin Clin Nutr Metab Care 10:597–603PubMedCrossRef Corder K, Brage S, Ekelund U (2007) Accelerometers and pedometers: methodology and clinical application. Curr Opin Clin Nutr Metab Care 10:597–603PubMedCrossRef
go back to reference Foss Ø, Hallén J (2005) Validity and stability of a computerized metabolic system with mixing chamber. Int J Sports Med 26(7):569–575PubMedCrossRef Foss Ø, Hallén J (2005) Validity and stability of a computerized metabolic system with mixing chamber. Int J Sports Med 26(7):569–575PubMedCrossRef
go back to reference Fruin ML, Rankin JW (2004) Validity of a multi-sensor armband in estimating rest and exercise energy expenditure. Med Sci Sports Exerc 36(6):1063–1069PubMedCrossRef Fruin ML, Rankin JW (2004) Validity of a multi-sensor armband in estimating rest and exercise energy expenditure. Med Sci Sports Exerc 36(6):1063–1069PubMedCrossRef
go back to reference King GA, Torres N, Potter C, Brooks TJ, Coleman KJ (2004) Comparison of activity monitors to estimate energy cost of treadmill exercise. Med Sci Sports Exerc 36(7):1244–1251PubMedCrossRef King GA, Torres N, Potter C, Brooks TJ, Coleman KJ (2004) Comparison of activity monitors to estimate energy cost of treadmill exercise. Med Sci Sports Exerc 36(7):1244–1251PubMedCrossRef
go back to reference Koehler K, deMarees M, Braun H, Schaenzer W (2010) Comparison of two portable devices for assessing energy expenditure during high-intensity running. Med Sci Sports Exerc 42(5 Suppl): S304–S305 Koehler K, deMarees M, Braun H, Schaenzer W (2010) Comparison of two portable devices for assessing energy expenditure during high-intensity running. Med Sci Sports Exerc 42(5 Suppl): S304–S305
go back to reference Malavolti M, Pietrobelli A, Dugoni M, Poli M, Romagnoli E, De Cristofaro P, Battistini NC (2007) A new device for measuring resting energy expenditure (REE) in healthy subjects. Nutr Metab Cardiovasc Dis 17(5):338–343PubMedCrossRef Malavolti M, Pietrobelli A, Dugoni M, Poli M, Romagnoli E, De Cristofaro P, Battistini NC (2007) A new device for measuring resting energy expenditure (REE) in healthy subjects. Nutr Metab Cardiovasc Dis 17(5):338–343PubMedCrossRef
go back to reference Malina RM (1995) Anthropometry. In: Maud PJ, Foster C (eds) Physiological assessment of human fitness. Human Kinetics, Champaign Malina RM (1995) Anthropometry. In: Maud PJ, Foster C (eds) Physiological assessment of human fitness. Human Kinetics, Champaign
go back to reference St-Onge M, Mignault D, Allison DB, Rabasa-Lhoret R (2007) Evaluation of a portable device to measure daily energy expenditure in free-living adults. Am J Clin Nutr 85:742–749PubMed St-Onge M, Mignault D, Allison DB, Rabasa-Lhoret R (2007) Evaluation of a portable device to measure daily energy expenditure in free-living adults. Am J Clin Nutr 85:742–749PubMed
go back to reference Troiano RP (2005) A timely meeting: objective measurement of physical activity. Med Sci Sports Exerc 37(11):S487–S489PubMedCrossRef Troiano RP (2005) A timely meeting: objective measurement of physical activity. Med Sci Sports Exerc 37(11):S487–S489PubMedCrossRef
go back to reference Welk GJ, Corbin CB, Dale D (2000) Measurement issues in the assessment of physical activity in children. Res Q Exerc Sport 71(2 Suppl):S59–S73PubMed Welk GJ, Corbin CB, Dale D (2000) Measurement issues in the assessment of physical activity in children. Res Q Exerc Sport 71(2 Suppl):S59–S73PubMed
Metadata
Title
Validation of the SenseWear Armband at high intensity exercise
Authors
Clemens Drenowatz
Joey C. Eisenmann
Publication date
01-05-2011
Publisher
Springer-Verlag
Published in
European Journal of Applied Physiology / Issue 5/2011
Print ISSN: 1439-6319
Electronic ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-010-1695-0

Other articles of this Issue 5/2011

European Journal of Applied Physiology 5/2011 Go to the issue