Skip to main content
Top
Published in: European Journal of Applied Physiology 6/2004

01-09-2004 | Original Article

Analysis of sensible heat exchanges from a thermal manikin

Authors: Divo Quintela, Adélio Gaspar, Carlos Borges

Published in: European Journal of Applied Physiology | Issue 6/2004

Login to get access

Abstract

The present work is dedicated to the analysis of dry heat exchanges as measured by a thermal manikin placed in still air. We believe that the understanding of some fundamental aspects governing fluid flow and heat transfer around three-dimensional bodies such as human beings deserves appropriate attention. This should be of great significance for improving physiological models concerned with thermal exposures. The potential interest of such work can be directed towards quite distinct targets such as working conditions, sports, the military, or healthcare personnel and patients. In the present study, we made use of a climate chamber and an articulated thermal manikin of the Pernille type, with 16 body parts. The most common occidental postures (standing, sitting and lying) were studied. In order to separate heat losses due to radiation and convection, the radiative heat losses of the manikin were significantly reduced by means of a shiny aluminium coating, which was carefully applied to the artificial skin. The air temperature within the test chamber was varied between 13°C and 29°C. The corresponding mean differences between the skin and the operative temperatures changed from 3.8°C up to 15.8°C. The whole-body heat transfer coefficients by radiation and convection for both standing and sitting postures are in good agreement with those in the published literature. The lying posture appears to be more efficient for losing heat by convection. This is confirmed when the heat losses of each individual part are considered. The proposed correlations for the whole body suggest that natural convection is mainly laminar.
Literature
go back to reference American Society of Heating Refrigerating and Air-Conditioning Engineers (ASHRAE) (2001) Thermal comfort. In: ASHRAE fundamentals handbook, chap 8. ASHRAE, Atlanta, Ga. American Society of Heating Refrigerating and Air-Conditioning Engineers (ASHRAE) (2001) Thermal comfort. In: ASHRAE fundamentals handbook, chap 8. ASHRAE, Atlanta, Ga.
go back to reference Borges C, Brites G, Gaspar A, Quintela D, Costa J (2002) Analysis of thermal plumes generated by a seated person, a thermal manikin and a dummy. In: Proceedings of ROOMVENT 2002, Copenhagen, Denmark, 8–11 September 2002 Borges C, Brites G, Gaspar A, Quintela D, Costa J (2002) Analysis of thermal plumes generated by a seated person, a thermal manikin and a dummy. In: Proceedings of ROOMVENT 2002, Copenhagen, Denmark, 8–11 September 2002
go back to reference De Dear R, Arens E, Hui Z, Oguro M (1997) Convective and radiative heat transfer coefficients for individual human body segments. Int J Biometeorol 40:141–156CrossRefPubMed De Dear R, Arens E, Hui Z, Oguro M (1997) Convective and radiative heat transfer coefficients for individual human body segments. Int J Biometeorol 40:141–156CrossRefPubMed
go back to reference Fanger P (1972) Thermal comfort. McGraw Hill, New York Fanger P (1972) Thermal comfort. McGraw Hill, New York
go back to reference House J, Tipton M (2002) Using skin temperature gradients or skin heat flux measurements to determine thresholds of vasoconstriction and vasodilatation. Eur J Appl Physiol 88:141–145 House J, Tipton M (2002) Using skin temperature gradients or skin heat flux measurements to determine thresholds of vasoconstriction and vasodilatation. Eur J Appl Physiol 88:141–145
go back to reference ISO 7730 (1994) Moderate thermal environments–determination of PMV and PPD indices and specification of the conditions for thermal comfort. ISO Standard, Geneva ISO 7730 (1994) Moderate thermal environments–determination of PMV and PPD indices and specification of the conditions for thermal comfort. ISO Standard, Geneva
go back to reference Murakami S (2002) CFD study on the micro-climate around the human body with inhalation and exhalation. In: Proceedings of ROOMVENT 2002, Copenhagen, Denmark, 8–11 September 2002 Murakami S (2002) CFD study on the micro-climate around the human body with inhalation and exhalation. In: Proceedings of ROOMVENT 2002, Copenhagen, Denmark, 8–11 September 2002
go back to reference Oguro M, Arens E, de Dear R, Zhang H, Katayama T (2002) Convective heat transfer coefficients and clothing insulations for parts of the clothed human body under calm conditions. J Archit Plann Environ Eng 561:31–39. Oguro M, Arens E, de Dear R, Zhang H, Katayama T (2002) Convective heat transfer coefficients and clothing insulations for parts of the clothed human body under calm conditions. J Archit Plann Environ Eng 561:31–39.
go back to reference Quintela D, Gaspar A, Mendes V, Silva M (1998) Evaluation of thermal environments in office buildings and schools. A Portuguese case study. ROOMVENT’98, the 6th international conference on air distribution in rooms, 14–17 June 1998, Stockholm, Sweden Quintela D, Gaspar A, Mendes V, Silva M (1998) Evaluation of thermal environments in office buildings and schools. A Portuguese case study. ROOMVENT’98, the 6th international conference on air distribution in rooms, 14–17 June 1998, Stockholm, Sweden
go back to reference Quintela D, Gaspar A, Raimundo (2000) A Development of local heating systems for thermal comfort and energy savings in buildings. Union Internationale Pour Applications De l’Electricite international conference, 1–4 November 2000, Lisbon, Portugal Quintela D, Gaspar A, Raimundo (2000) A Development of local heating systems for thermal comfort and energy savings in buildings. Union Internationale Pour Applications De l’Electricite international conference, 1–4 November 2000, Lisbon, Portugal
go back to reference Stolwijk J (1970) Mathematical model of thermoregulation. In: Hardy J (ed) Physical and behavioral temperature regulation. Thomas, Springfield, Ill., pp 703–721 Stolwijk J (1970) Mathematical model of thermoregulation. In: Hardy J (ed) Physical and behavioral temperature regulation. Thomas, Springfield, Ill., pp 703–721
go back to reference Tanabe S, Arens E, Bauman F, Zhang H, Madsen T (1994) Evaluating thermal environments by using a thermal manikin with controlled skin surface temperature. ASHRAE Transactions 100:39–48 Tanabe S, Arens E, Bauman F, Zhang H, Madsen T (1994) Evaluating thermal environments by using a thermal manikin with controlled skin surface temperature. ASHRAE Transactions 100:39–48
go back to reference Thellier F (1994) The analysis of thermal comfort requirements through the simulation of an occupied building. Ergonomics 37:817–825PubMed Thellier F (1994) The analysis of thermal comfort requirements through the simulation of an occupied building. Ergonomics 37:817–825PubMed
Metadata
Title
Analysis of sensible heat exchanges from a thermal manikin
Authors
Divo Quintela
Adélio Gaspar
Carlos Borges
Publication date
01-09-2004
Publisher
Springer-Verlag
Published in
European Journal of Applied Physiology / Issue 6/2004
Print ISSN: 1439-6319
Electronic ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-004-1132-3

Other articles of this Issue 6/2004

European Journal of Applied Physiology 6/2004 Go to the issue