01-02-2020 | Refractive Surgery

Optical quality in low astigmatic eyes with or without cylindrical correction

Authors: Qing-Qing Tan, Bai-Wei Wen, Xuan Liao, Jing Tian, Jia Lin, Chang-Jun Lan

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 2/2020

Login to get access

Abstract

Purpose

To investigate whether optical quality could be improved by cylindrical correction for low astigmatic eyes with different amounts and axis orientations in patients with myopia up to − 3.00 diopters (D).

Methods

A cross-sectional study enrolling healthy young eyes with 0 to − 3.00 D myopia and − 0.50 to − 0.75 D myopic astigmatism was implemented. With a repeated-measures design, outcome measures were sequentially obtained for each subject under two correction modalities: spherocylindrical correction and spherical correction. Subjective refraction was used to determine the refractive prescriptions accordingly in the two correction modalities to obtain optimal subject-reported visual acuity. Primary outcomes were optical quality parameters including objective scatter index (OSI), modulation transfer function (MTF) cut-off, Strehl ratio (SR), and a simulated contrast visual acuity-optical quality analysis system (OQAS) values (OV) obtained by a double-pass system. Corrected distance visual acuity (CDVA) was measured as a secondary outcome. Outcome comparisons between the two correction modalities were performed by grouping in different amounts (− 0.50 D, − 0.75 D) and axes (with the rule, WTR; against the rule, ATR; oblique, OBL) of astigmatism.

Results

A total of 194 eyes of 194 subjects were evaluated. Significantly better CDVA were shown by spherocylindrical correction for all types of astigmatism except for − 0.50 D WTR astigmatism (P = 0.831). For eyes with − 0.50 D WTR astigmatism, better outcome was only shown in OSI with spherocylindrical correction (P = 0.019). For eyes with − 0.50 D ATR and OBL astigmatism, spherocylindrical correction demonstrated better outcomes in all parameters except for SR (P > 0.05). For eyes with − 0.75 D astigmatism, significantly better outcomes in all optical quality parameters were shown with spherocylindrical correction regardless of the axis (P < 0.05).

Conclusions

Eyes with ATR or OBL myopic astigmatism may benefit in optical quality and visual acuity by combining a cylindrical correction even with a low amount down to − 0.50 D. However, optical quality and visual acuity improvement are limited for WTR astigmatic eyes when the amount of astigmatism is less than − 0.75 D.
Literature
10.
go back to reference Watanabe K, Negishi K, Dogru M, Yamaguchi T, Torii H, Tsubota K (2013) Effect of pupil size on uncorrected visual acuity in pseudophakic eyes with astigmatism. J Refract Surg 29:25–29CrossRef Watanabe K, Negishi K, Dogru M, Yamaguchi T, Torii H, Tsubota K (2013) Effect of pupil size on uncorrected visual acuity in pseudophakic eyes with astigmatism. J Refract Surg 29:25–29CrossRef
15.
go back to reference Pujol J, Arjona M, Arasa J, Badia V (1998) Influence of amount and changes in axis of astigmatism on retinal image quality. J Opt Soc Am A Opt Image Sci Vis 15:2514–2521CrossRef Pujol J, Arjona M, Arasa J, Badia V (1998) Influence of amount and changes in axis of astigmatism on retinal image quality. J Opt Soc Am A Opt Image Sci Vis 15:2514–2521CrossRef
19.
go back to reference Palomino C, Carmona D, Castillo A, Genol I, Clariana A (2010) Visual quality after presbyopia surgery. J Emmetropia 1:74–80 Palomino C, Carmona D, Castillo A, Genol I, Clariana A (2010) Visual quality after presbyopia surgery. J Emmetropia 1:74–80
30.
go back to reference Vilaseca M, Padilla A, Pujol J, Ondategui JC, Artal P, Guell JL (2009) Optical quality one month after verisyse and Veriflex phakic IOL implantation and Zeiss MEL 80 LASIK for myopia from 5.00 to 16.50 diopters. J Refract Surg 25:689–698CrossRef Vilaseca M, Padilla A, Pujol J, Ondategui JC, Artal P, Guell JL (2009) Optical quality one month after verisyse and Veriflex phakic IOL implantation and Zeiss MEL 80 LASIK for myopia from 5.00 to 16.50 diopters. J Refract Surg 25:689–698CrossRef
Metadata
Title
Optical quality in low astigmatic eyes with or without cylindrical correction
Authors
Qing-Qing Tan
Bai-Wei Wen
Xuan Liao
Jing Tian
Jia Lin
Chang-Jun Lan
Publication date
01-02-2020
Publisher
Springer Berlin Heidelberg
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 2/2020
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-019-04501-0

Other articles of this Issue 2/2020

Graefe's Archive for Clinical and Experimental Ophthalmology 2/2020 Go to the issue