Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 10/2014

01-10-2014 | Glaucoma

Correlation between early retinal nerve fiber layer loss and visual field loss determined by three different perimetric strategies: white-on-white, frequency-doubling, or flicker-defined form perimetry

Authors: Verena Prokosch, Nicole Eter

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 10/2014

Login to get access

Abstract

Purpose

To compare the significance of white-on-white standard automated perimetry (SAP), matrix frequency doubling technology (FDT), and flicker-defined form perimetry (FDF) for early detection of nerve fiber layer loss in early glaucoma patients.

Methods

Fifty-one healthy controls and 40 patients with early glaucomatous nerve fiber loss were enrolled in this study. Patients had retinal nerve fiber layer (RNFL) imaging and visual field testing by SAP, FDT matrix, and FDF perimetry at the same visit. Visual field defects were confirmed with two or more consecutive examinations by the same types of perimetry. Significant retinal nerve fiber layer loss and thus early glaucoma was defined with the reference to the RNFL thickness deviation map. The sensitivity, specificity, correlation, MD (mean deviation) and PSD (pattern standard deviation) visual field indexes, and area under the receiver operating characteristic curve (AUC) of MD and PSD of the perimetries were compared.

Results

There was a significant difference in nerve fiber layer thickness between healthy patients (97.7 ± 1.34 μm and patients with early glaucoma (84.1 ± 1.58 μm) (p < 0.001). Taking all patients with early glaucoma into consideration, the sensitivity was highest for FDF perimetry (87 %), followed by FDT matrix (62.5 %), and then SAP (40 %). The specificity was 69.2 % for SAP, 62.8 % for FDT matrix, and 38.4 % for FDF perimetry. MD (mean deviation) and PSD (pattern standard deviation) in FDF and FDT matrix were significantly different between patients with RNFL loss and those without (p < 0.05), while no difference could be found in SAP. The AUCs of MD followed a similar pattern, with FDF and FDT matrix perimetry having a suitable AUC of >0.6. AUCs of PSD were not reliable in all of the three VF devices.

Conclusions

The sensitivity for detection of RNFL loss in early glaucoma seems to be higher in FDF and FDT matrix than SAP perimetry, while specifity was highest in SAP. Thus, simultaneous performance of FDF/FDT matrix and SAP perimetry seems beneficial for the correct diagnosis of early glaucoma in patients.
Literature
2.
go back to reference Clement CI, Goldberg I, Healey PR, Graham S (2009) Humphrey matrix frequency doubling perimetry for detection of visual-field defects in open-angle glaucoma. Br J Ophthalmol 93:582–588PubMedCrossRef Clement CI, Goldberg I, Healey PR, Graham S (2009) Humphrey matrix frequency doubling perimetry for detection of visual-field defects in open-angle glaucoma. Br J Ophthalmol 93:582–588PubMedCrossRef
3.
go back to reference Kim TW, Zangwill LM, Bowd C, Sample PA, Shah N, Weinreb RN (2007) Retinal nerve fiber layer damage as assessed by optical coherence tomography in eyes with a visual field defect detected by frequency doubling technology perimetry but not by standard automated perimetry. Ophthalmology 114:1053–1057PubMedCrossRef Kim TW, Zangwill LM, Bowd C, Sample PA, Shah N, Weinreb RN (2007) Retinal nerve fiber layer damage as assessed by optical coherence tomography in eyes with a visual field defect detected by frequency doubling technology perimetry but not by standard automated perimetry. Ophthalmology 114:1053–1057PubMedCrossRef
4.
go back to reference Harwerth RS, Carter-Dawson L, Shen F, Smith EL 3rd, Crawford ML (1999) Ganglion cell losses underlying visual field defects from experimental glaucoma. Invest Ophthalmol Vis Sci 40:2242–2250PubMed Harwerth RS, Carter-Dawson L, Shen F, Smith EL 3rd, Crawford ML (1999) Ganglion cell losses underlying visual field defects from experimental glaucoma. Invest Ophthalmol Vis Sci 40:2242–2250PubMed
5.
go back to reference Johnson CA (1995) The Glenn A. Fry Award lecture. Early losses of visual function in glaucoma. Optom Vis Sci 72:359–370PubMedCrossRef Johnson CA (1995) The Glenn A. Fry Award lecture. Early losses of visual function in glaucoma. Optom Vis Sci 72:359–370PubMedCrossRef
6.
go back to reference Kondo Y, Yamamoto T, Sato Y, Matsubara M, Kitazawa Y (1998) A frequency-doubling perimetric study in normal-tension glaucoma with hemifield defect. J Glaucoma 7:261–265PubMed Kondo Y, Yamamoto T, Sato Y, Matsubara M, Kitazawa Y (1998) A frequency-doubling perimetric study in normal-tension glaucoma with hemifield defect. J Glaucoma 7:261–265PubMed
7.
go back to reference Medeiros FA, Sample PA, Weinreb RN (2004) Frequency doubling technology perimetry abnormalities as predictors of glaucomatous visual field loss. Am J Ophthalmol 137:863–871PubMedCrossRef Medeiros FA, Sample PA, Weinreb RN (2004) Frequency doubling technology perimetry abnormalities as predictors of glaucomatous visual field loss. Am J Ophthalmol 137:863–871PubMedCrossRef
8.
go back to reference Martin PR, White AJ, Goodchild AK, Wilder HD, Sefton AE (1997) Evidence that blue-on cells are part of the third geniculocortical pathway in primates. Eur J Neurosci 9:1536–1541PubMedCrossRef Martin PR, White AJ, Goodchild AK, Wilder HD, Sefton AE (1997) Evidence that blue-on cells are part of the third geniculocortical pathway in primates. Eur J Neurosci 9:1536–1541PubMedCrossRef
9.
go back to reference Johnson CA (1994) Selective versus nonselective losses in glaucoma. J Glaucoma 1:32–44 Johnson CA (1994) Selective versus nonselective losses in glaucoma. J Glaucoma 1:32–44
10.
go back to reference White AJ, Sun H, Swanson WH, Lee BB (2002) An examination of physiological mechanisms underlying the frequency-doubling illusion. Invest Ophthalmol Vis Sci 43:3590–3599PubMed White AJ, Sun H, Swanson WH, Lee BB (2002) An examination of physiological mechanisms underlying the frequency-doubling illusion. Invest Ophthalmol Vis Sci 43:3590–3599PubMed
11.
go back to reference Sample PA, Bosworth CF, Blumenthal EZ, Girkin C, Weinreb RN (2000) Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma. Invest Ophthalmol Vis Sci 41:1783–1790PubMed Sample PA, Bosworth CF, Blumenthal EZ, Girkin C, Weinreb RN (2000) Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma. Invest Ophthalmol Vis Sci 41:1783–1790PubMed
12.
go back to reference Spry PG, Johnson CA, McKendrick AM, Turpin A (2001) Variability components of standard automated perimetry and frequency-doubling technology perimetry. Invest Ophthalmol Vis Sci 42:1404–1410PubMed Spry PG, Johnson CA, McKendrick AM, Turpin A (2001) Variability components of standard automated perimetry and frequency-doubling technology perimetry. Invest Ophthalmol Vis Sci 42:1404–1410PubMed
13.
go back to reference Lamparter J, Aliyeva S, Schulze A, Berres M, Pfeiffer N, Hoffmann EM (2013) Standard automated perimetry versus matrix frequency doubling technology perimetry in subjects with ocular hypertension and healthy control subjects. PLoS One 8:e57663PubMedCrossRefPubMedCentral Lamparter J, Aliyeva S, Schulze A, Berres M, Pfeiffer N, Hoffmann EM (2013) Standard automated perimetry versus matrix frequency doubling technology perimetry in subjects with ocular hypertension and healthy control subjects. PLoS One 8:e57663PubMedCrossRefPubMedCentral
14.
go back to reference Lamparter J, Russell RA, Schulze A, Schuff AC, Pfeiffer N, Hoffmann EM (2012) Structure–function relationship between FDF, FDT, SAP, and scanning laser ophthalmoscopy in glaucoma patients. Invest Ophthalmol Vis Sci 53:7553–7559PubMedCrossRef Lamparter J, Russell RA, Schulze A, Schuff AC, Pfeiffer N, Hoffmann EM (2012) Structure–function relationship between FDF, FDT, SAP, and scanning laser ophthalmoscopy in glaucoma patients. Invest Ophthalmol Vis Sci 53:7553–7559PubMedCrossRef
15.
go back to reference Spry PG, Johnson CA, Mansberger SL, Cioffi GA (2005) Psychophysical investigation of ganglion cell loss in early glaucoma. J Glaucoma 14:11–19PubMedCrossRef Spry PG, Johnson CA, Mansberger SL, Cioffi GA (2005) Psychophysical investigation of ganglion cell loss in early glaucoma. J Glaucoma 14:11–19PubMedCrossRef
16.
go back to reference Sample PA, Medeiros FA, Racette L et al (2006) Identifying glaucomatous vision loss with visual-function-specific perimetry in the diagnostic innovations in glaucoma study. Invest Ophthalmol Vis Sci 47:3381–3389PubMedCrossRef Sample PA, Medeiros FA, Racette L et al (2006) Identifying glaucomatous vision loss with visual-function-specific perimetry in the diagnostic innovations in glaucoma study. Invest Ophthalmol Vis Sci 47:3381–3389PubMedCrossRef
17.
go back to reference Mulak M, Szumny D, Sieja-Bujewska A, Kubrak M (2012) Heidelberg Edge Perimeter employment in glaucoma diagnosis–preliminary report. Adv Clin Exp Med 21:665–670PubMed Mulak M, Szumny D, Sieja-Bujewska A, Kubrak M (2012) Heidelberg Edge Perimeter employment in glaucoma diagnosis–preliminary report. Adv Clin Exp Med 21:665–670PubMed
18.
go back to reference Racette L, Medeiros FA, Zangwill LM, Ng D, Weinreb RN, Sample PA (2008) Diagnostic accuracy of the matrix 24–2 and original N-30 frequency-doubling technology tests compared with standard automated perimetry. Invest Ophthalmol Vis Sci 49:954–960PubMedCrossRefPubMedCentral Racette L, Medeiros FA, Zangwill LM, Ng D, Weinreb RN, Sample PA (2008) Diagnostic accuracy of the matrix 24–2 and original N-30 frequency-doubling technology tests compared with standard automated perimetry. Invest Ophthalmol Vis Sci 49:954–960PubMedCrossRefPubMedCentral
19.
20.
go back to reference Liu S, Lam S, Weinreb RN et al (2011) Comparison of standard automated perimetry, frequency-doubling technology perimetry, and short-wavelength automated perimetry for detection of glaucoma. Invest Ophthalmol Vis Sci 52:7325–7331PubMedCrossRef Liu S, Lam S, Weinreb RN et al (2011) Comparison of standard automated perimetry, frequency-doubling technology perimetry, and short-wavelength automated perimetry for detection of glaucoma. Invest Ophthalmol Vis Sci 52:7325–7331PubMedCrossRef
21.
go back to reference Hasler S, Sturmer J (2012) First experience with the Heidelberg Edge Perimeter on patients with ocular hypertension and preperimetric glaucoma. Klin Monatsbl Augenheilkd 229:319–322PubMedCrossRef Hasler S, Sturmer J (2012) First experience with the Heidelberg Edge Perimeter on patients with ocular hypertension and preperimetric glaucoma. Klin Monatsbl Augenheilkd 229:319–322PubMedCrossRef
22.
go back to reference Pinto LM, Costa EF, Melo LA Jr et al (2014) Structure–function correlations in glaucoma using matrix and standard automated perimetry versus time-domain and spectral-domain OCT devices. Invest Ophthalmol Vis Sci 55:3074–3080PubMedCrossRef Pinto LM, Costa EF, Melo LA Jr et al (2014) Structure–function correlations in glaucoma using matrix and standard automated perimetry versus time-domain and spectral-domain OCT devices. Invest Ophthalmol Vis Sci 55:3074–3080PubMedCrossRef
23.
go back to reference Cellini M, Toschi PG, Strobbe E, Balducci N, Campos EC (2012) Frequency doubling technology, optical coherence technology and pattern electroretinogram in ocular hypertension. BMC Ophthalmol 1:12–33 Cellini M, Toschi PG, Strobbe E, Balducci N, Campos EC (2012) Frequency doubling technology, optical coherence technology and pattern electroretinogram in ocular hypertension. BMC Ophthalmol 1:12–33
24.
go back to reference Reus NJ, Lemij HG, Garway-Heath DF et al (2010) Clinical assessment of stereoscopic optic disc photographs for glaucoma: The European Optic Disc Assessment Trial. Ophthalmology 117:717–723PubMedCrossRef Reus NJ, Lemij HG, Garway-Heath DF et al (2010) Clinical assessment of stereoscopic optic disc photographs for glaucoma: The European Optic Disc Assessment Trial. Ophthalmology 117:717–723PubMedCrossRef
25.
go back to reference Jampel HD, Friedman D, Quigley H et al (2009) Agreement among glaucoma specialists in assessing progressive disc changes from photographs in open-angle glaucoma patients. Am J Ophthalmol 147:39–44.e1PubMedCrossRefPubMedCentral Jampel HD, Friedman D, Quigley H et al (2009) Agreement among glaucoma specialists in assessing progressive disc changes from photographs in open-angle glaucoma patients. Am J Ophthalmol 147:39–44.e1PubMedCrossRefPubMedCentral
27.
go back to reference Leung CK, Lam S, Weinreb RN et al (2010) Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: analysis of the retinal nerve fiber layer map for glaucoma detection. Ophthalmology 117:1684–1691PubMedCrossRef Leung CK, Lam S, Weinreb RN et al (2010) Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: analysis of the retinal nerve fiber layer map for glaucoma detection. Ophthalmology 117:1684–1691PubMedCrossRef
28.
go back to reference Hood DC, Anderson SC, Wall M, Raza AS, Kardon RH (2009) A test of a linear model of glaucomatous structure-function loss reveals sources of variability in retinal nerve fiber and visual field measurements. Invest Ophthalmol Vis Sci 50:4254–4266PubMedCrossRefPubMedCentral Hood DC, Anderson SC, Wall M, Raza AS, Kardon RH (2009) A test of a linear model of glaucomatous structure-function loss reveals sources of variability in retinal nerve fiber and visual field measurements. Invest Ophthalmol Vis Sci 50:4254–4266PubMedCrossRefPubMedCentral
29.
go back to reference Hood DC, Fortune B, Arthur SN et al (2008) Blood vessel contributions to retinal nerve fiber layer thickness profiles measured with optical coherence tomography. J Glaucoma 17:519–528PubMedCrossRefPubMedCentral Hood DC, Fortune B, Arthur SN et al (2008) Blood vessel contributions to retinal nerve fiber layer thickness profiles measured with optical coherence tomography. J Glaucoma 17:519–528PubMedCrossRefPubMedCentral
Metadata
Title
Correlation between early retinal nerve fiber layer loss and visual field loss determined by three different perimetric strategies: white-on-white, frequency-doubling, or flicker-defined form perimetry
Authors
Verena Prokosch
Nicole Eter
Publication date
01-10-2014
Publisher
Springer Berlin Heidelberg
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 10/2014
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-014-2718-z

Other articles of this Issue 10/2014

Graefe's Archive for Clinical and Experimental Ophthalmology 10/2014 Go to the issue