Skip to main content
Top
Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 4/2013

01-04-2013 | Retinal Disorders

Overestimation of subfoveal choroidal thickness by measurement based on horizontally compressed optical coherence tomography images

Authors: Jae Hui Kim, Se Woong Kang, Hyo Shin Ha, Sang Jin Kim, Jae Ryung Kim

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 4/2013

Login to get access

Abstract

Purpose

To measure the difference in subfoveal choroidal thickness between 1:1 pixel (horizontally compressed) images and 1:1 micron images in age-related macular degeneration.

Methods

This study included 122 eyes from 122 patients diagnosed with age-related macular degeneration. Choroidal thickness was measured using enhanced-depth imaging optical coherence tomography. The measurement line was drawn as a perpendicular line between Bruch’s membrane and the chorio-scleral interface. The thickness was compared between measurements based on a 1:1 pixel image and a 1:1 micron image. Eyes with a straight vertical measurement line and oblique measurement line were classified into vertical measurement group and oblique measurement group, respectively. Intra-group comparisons of subfoveal choroidal thickness measurements based on the 1:1 pixel images and the 1:1 micron images were performed for the two groups.

Results

The mean subfoveal choroidal thicknesses measured on the 1:1 pixel images and the 1:1 micron images were 232.3 ± 106.4 μm and 228.9 ± 108.1 μm, respectively (p = 0.003). In the vertical measurement group (86 eyes), the mean subfoveal choroidal thickness was 226.3 ± 109.9 μm and 225.4 ± 112.0 μm, respectively (p = 0.423). In the oblique measurement group (36 eyes), the thickness was 246.5 ± 97.3 μm and 237.5 ± 98.9 μm, respectively (p < 0.001).

Conclusions

Significant overestimation of the subfoveal choroidal thickness was noted when it was measured on a 1:1 pixel image. This finding suggests that the measurement of choroidal thickness should be performed based on a 1:1 micron image, especially if the measurement line is not vertical.
Literature
1.
go back to reference Spaide RF, Koizumi H, Pozzoni MC (2008) Enhanced depth imaging spectral-domain optical coherence tomography. Am J Ophthalmol 146:496–500PubMedCrossRef Spaide RF, Koizumi H, Pozzoni MC (2008) Enhanced depth imaging spectral-domain optical coherence tomography. Am J Ophthalmol 146:496–500PubMedCrossRef
2.
go back to reference Margolis R, Spaide RF (2009) A pilot study of enhanced depth imaging optical coherence tomography of the choroid in normal eyes. Am J Ophthalmol 147:811–815PubMedCrossRef Margolis R, Spaide RF (2009) A pilot study of enhanced depth imaging optical coherence tomography of the choroid in normal eyes. Am J Ophthalmol 147:811–815PubMedCrossRef
3.
go back to reference Chung SE, Kang SW, Lee JH, Kim YT (2011) Choroidal thickness in polypoidal choroidal vasculopathy and exudative age-related macular degeneration. Ophthalmology 118:840–845PubMedCrossRef Chung SE, Kang SW, Lee JH, Kim YT (2011) Choroidal thickness in polypoidal choroidal vasculopathy and exudative age-related macular degeneration. Ophthalmology 118:840–845PubMedCrossRef
4.
go back to reference Koizumi H, Yamagishi T, Yamazaki T, Kawasaki R, Kinoshita S (2011) Subfoveal choroidal thickness in typical age-related macular degeneration and polypoidal choroidal vasculopathy. Graefes Arch Clin Exp Ophthalmol 249:1123–1128PubMedCrossRef Koizumi H, Yamagishi T, Yamazaki T, Kawasaki R, Kinoshita S (2011) Subfoveal choroidal thickness in typical age-related macular degeneration and polypoidal choroidal vasculopathy. Graefes Arch Clin Exp Ophthalmol 249:1123–1128PubMedCrossRef
5.
go back to reference Kim SW, Oh J, Kwon SS, Yoo J, Huh K (2011) Comparison of choroidal thickness among patients with healthy eyes, early age-related maculopathy, neovascular age-related macular degeneration, central serous chorioretinopathy, and polypoidal choroidal vasculopathy. Retina 31:1904–1911PubMedCrossRef Kim SW, Oh J, Kwon SS, Yoo J, Huh K (2011) Comparison of choroidal thickness among patients with healthy eyes, early age-related maculopathy, neovascular age-related macular degeneration, central serous chorioretinopathy, and polypoidal choroidal vasculopathy. Retina 31:1904–1911PubMedCrossRef
6.
go back to reference Manjunath V, Goren J, Fujimoto JG, Duker JS (2011) Analysis of choroidal thickness in age-related macular degeneration using spectral-domain optical coherence tomography. Am J Ophthalmol 152:663–668PubMedCrossRef Manjunath V, Goren J, Fujimoto JG, Duker JS (2011) Analysis of choroidal thickness in age-related macular degeneration using spectral-domain optical coherence tomography. Am J Ophthalmol 152:663–668PubMedCrossRef
7.
go back to reference Maruko I, Iida T, Sugano Y, Ojima A, Ogasawara M, Spaide RF (2010) Subfoveal choroidal thickness after treatment of central serous chorioretinopathy. Ophthalmology 117:1792–1799PubMedCrossRef Maruko I, Iida T, Sugano Y, Ojima A, Ogasawara M, Spaide RF (2010) Subfoveal choroidal thickness after treatment of central serous chorioretinopathy. Ophthalmology 117:1792–1799PubMedCrossRef
8.
go back to reference Imamura Y, Fujiwara T, Margolis R, Spaide RF (2009) Enhanced depth imaging optical coherence tomography of the choroid in central serous chorioretinopathy. Retina 29:1469–1473PubMedCrossRef Imamura Y, Fujiwara T, Margolis R, Spaide RF (2009) Enhanced depth imaging optical coherence tomography of the choroid in central serous chorioretinopathy. Retina 29:1469–1473PubMedCrossRef
9.
go back to reference Maruko I, Iida T, Sugano Y, Saito M, Sekiryu T (2011) Subfoveal retinal and choroidal thickness after verteporfin photodynamic therapy for polypoidal choroidal vasculopathy. Am J Ophthalmol 151:594–603PubMedCrossRef Maruko I, Iida T, Sugano Y, Saito M, Sekiryu T (2011) Subfoveal retinal and choroidal thickness after verteporfin photodynamic therapy for polypoidal choroidal vasculopathy. Am J Ophthalmol 151:594–603PubMedCrossRef
10.
go back to reference Rahman W, Chen FK, Yeoh J, Patel P, Tufail A, Da Cruz L (2011) Repeatability of manual subfoveal choroidal thickness measurements in healthy subjects using the technique of enhanced depth imaging optical coherence tomography. Invest Ophthalmol Vis Sci 52:2267–2271PubMedCrossRef Rahman W, Chen FK, Yeoh J, Patel P, Tufail A, Da Cruz L (2011) Repeatability of manual subfoveal choroidal thickness measurements in healthy subjects using the technique of enhanced depth imaging optical coherence tomography. Invest Ophthalmol Vis Sci 52:2267–2271PubMedCrossRef
11.
go back to reference Ding X, Li J, Zeng J, Ma W, Liu R, Li T, Yu S, Tang S (2011) Choroidal thickness in healthy Chinese subjects. Invest Ophthalmol Vis Sci 52:9555–9560PubMedCrossRef Ding X, Li J, Zeng J, Ma W, Liu R, Li T, Yu S, Tang S (2011) Choroidal thickness in healthy Chinese subjects. Invest Ophthalmol Vis Sci 52:9555–9560PubMedCrossRef
12.
go back to reference Branchini L, Regatieri CV, Flores-Moreno I, Baumann B, Fujimoto JG, Duker JS (2012) Reproducibility of choroidal thickness measurements across three spectral domain optical coherence tomography systems. Ophthalmology 119:119–123PubMedCrossRef Branchini L, Regatieri CV, Flores-Moreno I, Baumann B, Fujimoto JG, Duker JS (2012) Reproducibility of choroidal thickness measurements across three spectral domain optical coherence tomography systems. Ophthalmology 119:119–123PubMedCrossRef
13.
go back to reference Tan CS, Ouyang Y, Ruiz H, Sadda SR (2011) Diurnal variation of choroidal thickness in normal, healthy subjects. Invest Ophthalmol Vis Sci doi:10.1167/iovs.11-8782 Tan CS, Ouyang Y, Ruiz H, Sadda SR (2011) Diurnal variation of choroidal thickness in normal, healthy subjects. Invest Ophthalmol Vis Sci doi:10.​1167/​iovs.​11-8782
14.
go back to reference Querques G, Querques L, Forte R, Massamba N, Coscas F, Souied EH (2012) Choroidal changes associated with reticular pseudodrusen. Invest Ophthalmol Vis Sci. doi:10.1167/iovs.11-8907 Querques G, Querques L, Forte R, Massamba N, Coscas F, Souied EH (2012) Choroidal changes associated with reticular pseudodrusen. Invest Ophthalmol Vis Sci. doi:10.​1167/​iovs.​11-8907
15.
go back to reference Hirata M, Tsujikawa A, Matsumoto A, Hangai M, Ooto S, Yamashiro K, Akiba M, Yoshimura N (2011) Macular choroidal thickness and volume in normal subjects measured by swept-source optical coherence tomography. Invest Ophthalmol Vis Sci 52:4971–4978PubMedCrossRef Hirata M, Tsujikawa A, Matsumoto A, Hangai M, Ooto S, Yamashiro K, Akiba M, Yoshimura N (2011) Macular choroidal thickness and volume in normal subjects measured by swept-source optical coherence tomography. Invest Ophthalmol Vis Sci 52:4971–4978PubMedCrossRef
16.
go back to reference Esmaeelpour M, Povazay B, Hermann B, Hofer B, Kajic V, Hale SL, North RV, Drexler W, Sheen NJ (2011) Mapping choroidal and retinal thickness variation in type 2 diabetes using three-dimensional 1060-nm optical coherence tomography. Invest Ophthalmol Vis Sci 52:5311–5316PubMedCrossRef Esmaeelpour M, Povazay B, Hermann B, Hofer B, Kajic V, Hale SL, North RV, Drexler W, Sheen NJ (2011) Mapping choroidal and retinal thickness variation in type 2 diabetes using three-dimensional 1060-nm optical coherence tomography. Invest Ophthalmol Vis Sci 52:5311–5316PubMedCrossRef
Metadata
Title
Overestimation of subfoveal choroidal thickness by measurement based on horizontally compressed optical coherence tomography images
Authors
Jae Hui Kim
Se Woong Kang
Hyo Shin Ha
Sang Jin Kim
Jae Ryung Kim
Publication date
01-04-2013
Publisher
Springer-Verlag
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 4/2013
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-012-2147-9

Other articles of this Issue 4/2013

Graefe's Archive for Clinical and Experimental Ophthalmology 4/2013 Go to the issue