Skip to main content
Top
Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 3/2013

01-03-2013 | Glaucoma

Comparison of ganglion cell and retinal nerve fiber layer thickness in primary open-angle glaucoma and normal tension glaucoma with spectral-domain OCT

Authors: Penpe Gul Firat, Selim Doganay, Ersan Ersin Demirel, Cemil Colak

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 3/2013

Login to get access

Abstract

Background

The aim of this study was to evaluate the macular thickness (MT), ganglion cell complex (GCC), and circum-papillary retinal nerve fiber layer (RNFL) thickness in primary open-angle glaucoma (POAG) and normal tension glaucoma (NTG) with spectral domain optical coherence tomography (SD-OCT).

Methods

A total of 169 subjects were enrolled: 52 normal subjects, 61 with POAG, and 56 with NTG. Spectral-domain optical coherence tomography (SD-OCT) was used to analyze MT, GCC, and RNFL thickness. To compare the discrimination capabilities between the MT, GCC, and RNFL thickness measurements, we analyzed the areas under the receiver operating characteristic (ROC) curves (AUCs). The relationships between GCC and RNFL measurement and also the relationships of the groups, with age, gender, GCC, and RNFL thickness were assessed.

Results

Normal subjects showed the thickest superior and inferior GCC, followed by in order NTG and POAG (p < 0.05). While there was a statistically difference in MT value of the normal subjects and the glaucoma patients (p < 0.05), MT value did not differ between POAG and NTG (p < 0.05). RNFL thickness parameters were significantly greater in normal subjects, followed in order by the NTG, and POAG (p < 0.05). Between the normal and entire glaucoma groups, all GCC and RNFL parameters showed the similar discrimination power. RNFL thickness parameters correlated significantly with all GCC thickness (p < 0.05). Superior RNFL thickness was the only independent variable between the POAG and NTG patients (odds ratio (OR) 0.942, p = 0.004, 95 %CI 0.905–0.981).

Conclusions

SD-OCT evaluation results suggest higher GCC and RNFL parameters for NTG than POAG.
Literature
1.
go back to reference Gutteridge IF (2000) Normal tension glaucoma: diagnostic features and comparisons with primary open angle glaucoma. Clin Exp Optom 83:161–172PubMedCrossRef Gutteridge IF (2000) Normal tension glaucoma: diagnostic features and comparisons with primary open angle glaucoma. Clin Exp Optom 83:161–172PubMedCrossRef
3.
go back to reference Caprioli J, Spaeth GL (1985) Comparison of the optic nerve head in high- and low-tension glaucoma. Arch Ophthalmol 103:1145–1149PubMedCrossRef Caprioli J, Spaeth GL (1985) Comparison of the optic nerve head in high- and low-tension glaucoma. Arch Ophthalmol 103:1145–1149PubMedCrossRef
4.
go back to reference Hitchings RA, Anderton SA (1983) A comparative study of visual field defects in low-tension glaucoma and chronic simple glaucoma. Br J Ophthalmol 67:818–821PubMedCrossRef Hitchings RA, Anderton SA (1983) A comparative study of visual field defects in low-tension glaucoma and chronic simple glaucoma. Br J Ophthalmol 67:818–821PubMedCrossRef
5.
go back to reference Kitazawa Y, Shirato S, Yamamoto T (1986) Optic disc haemorrhage in low-tension glaucoma. Ophthalmology 93:853–857PubMed Kitazawa Y, Shirato S, Yamamoto T (1986) Optic disc haemorrhage in low-tension glaucoma. Ophthalmology 93:853–857PubMed
6.
go back to reference Zeimer R, Asrani S, Zou S, Quigley H, Jampel H (1998) Quantitative detection of glaucomatous damage at the posterior pole by retinal thickness mapping. Ophthalmology 105:224–231PubMedCrossRef Zeimer R, Asrani S, Zou S, Quigley H, Jampel H (1998) Quantitative detection of glaucomatous damage at the posterior pole by retinal thickness mapping. Ophthalmology 105:224–231PubMedCrossRef
7.
go back to reference Ojima T, Tanabe T, Hangai M, Yu S, Morishita S, Yoshimura N (2007) Measurement of retinal nerve fiber layer thickness and macular volume for glaucoma detection using optical coherence tomography. Jpn J Ophthalmol 51:197–203PubMedCrossRef Ojima T, Tanabe T, Hangai M, Yu S, Morishita S, Yoshimura N (2007) Measurement of retinal nerve fiber layer thickness and macular volume for glaucoma detection using optical coherence tomography. Jpn J Ophthalmol 51:197–203PubMedCrossRef
8.
go back to reference Choi MG, Han M, Kim YI, Lee JH (2005) Comparison of glaucomatous parameters in normal, ocular hypertensive and glaucomatous eyes using optical coherence tomography 3000. Korean J Ophthalmol 19:40–46PubMedCrossRef Choi MG, Han M, Kim YI, Lee JH (2005) Comparison of glaucomatous parameters in normal, ocular hypertensive and glaucomatous eyes using optical coherence tomography 3000. Korean J Ophthalmol 19:40–46PubMedCrossRef
9.
go back to reference Greenfield DS, Bagga H, Knighton RW (2003) Macular thickness changes in glaucomatous optic neuropathy detected using optical coherence tomography. Arch Ophthalmol 121:41–46PubMedCrossRef Greenfield DS, Bagga H, Knighton RW (2003) Macular thickness changes in glaucomatous optic neuropathy detected using optical coherence tomography. Arch Ophthalmol 121:41–46PubMedCrossRef
10.
go back to reference Tan O, Li G, Lu AT, Varma R, Huang D (2008) Advanced Imaging for Glaucoma Study Group. Mapping of macular substructures with optical coherence tomography for glaucoma diagnosis. Ophthalmology 115:949–956PubMedCrossRef Tan O, Li G, Lu AT, Varma R, Huang D (2008) Advanced Imaging for Glaucoma Study Group. Mapping of macular substructures with optical coherence tomography for glaucoma diagnosis. Ophthalmology 115:949–956PubMedCrossRef
11.
go back to reference Nakamura H, Hangai M, Mori S, Hirose F, Yoshimura N (2011) Hemispherical focal macular photopic negative response and macular inner retinal thickness in open-angle glaucoma. Am J Ophthalmol 151:494–506PubMedCrossRef Nakamura H, Hangai M, Mori S, Hirose F, Yoshimura N (2011) Hemispherical focal macular photopic negative response and macular inner retinal thickness in open-angle glaucoma. Am J Ophthalmol 151:494–506PubMedCrossRef
12.
go back to reference Leung CK, Chan WM, Yung WH, Ng AC, Woo J, Tsang MK, Tse RK (2005) Comparison of macular and peripapillary measurements for the detection of glaucoma: an optical coherence tomography study. Ophthalmology 112:391–400PubMedCrossRef Leung CK, Chan WM, Yung WH, Ng AC, Woo J, Tsang MK, Tse RK (2005) Comparison of macular and peripapillary measurements for the detection of glaucoma: an optical coherence tomography study. Ophthalmology 112:391–400PubMedCrossRef
13.
go back to reference Hodapp E, Parrish RK II, Anderson DR (1993) Clinical decisions in glaucoma. Mosby, St. Louis Hodapp E, Parrish RK II, Anderson DR (1993) Clinical decisions in glaucoma. Mosby, St. Louis
14.
go back to reference Langenegger SJ, Funk J, Töteberg-Harms M (2011) Reproducibility of retinal nerve fiber layer thickness measurements using the eye tracker and the retest function of Spectralis SD-OCT in glaucomatous and healthy control eyes. Invest Ophthalmol Vis Sci 52:3338–3344PubMedCrossRef Langenegger SJ, Funk J, Töteberg-Harms M (2011) Reproducibility of retinal nerve fiber layer thickness measurements using the eye tracker and the retest function of Spectralis SD-OCT in glaucomatous and healthy control eyes. Invest Ophthalmol Vis Sci 52:3338–3344PubMedCrossRef
15.
go back to reference Savini G, Carbonelli M, Barboni P (2011) Spectral-domain optical coherence tomography for the diagnosis and follow-up of glaucoma. Curr Opin Ophthalmol 22:115–123PubMedCrossRef Savini G, Carbonelli M, Barboni P (2011) Spectral-domain optical coherence tomography for the diagnosis and follow-up of glaucoma. Curr Opin Ophthalmol 22:115–123PubMedCrossRef
16.
go back to reference Seong M, Sung KR, Choi EH, Kang SY, Cho JW, Um TW, Kim YJ, Park SB, Hong HE, Kook MS (2010) Macular and peripapillary retinal nerve fiber layer measurements by spectral domain optical coherence tomography in normal-tension glaucoma. Invest Ophthalmol Vis Sci 51:1446–1452PubMedCrossRef Seong M, Sung KR, Choi EH, Kang SY, Cho JW, Um TW, Kim YJ, Park SB, Hong HE, Kook MS (2010) Macular and peripapillary retinal nerve fiber layer measurements by spectral domain optical coherence tomography in normal-tension glaucoma. Invest Ophthalmol Vis Sci 51:1446–1452PubMedCrossRef
17.
go back to reference Rao HL, Zangwill LM, Weinreb RN, Sample PA, Alencar LM, Medeiros FA (2010) Comparison of different spectral domain optical coherence tomography scanning areas for glaucoma diagnosis. Ophthalmology 117:1692–1699PubMedCrossRef Rao HL, Zangwill LM, Weinreb RN, Sample PA, Alencar LM, Medeiros FA (2010) Comparison of different spectral domain optical coherence tomography scanning areas for glaucoma diagnosis. Ophthalmology 117:1692–1699PubMedCrossRef
18.
go back to reference Chen J, Huang H, Wang M, Sun X, Qian S (2012) Fourier domain OCT measurement of macular, macular ganglion cell complex, and peripapillary RNFL thickness in glaucomatous Chinese eyes. Eur J Ophthalmol Mar 20 [Epub ahead of print]. doi:10.5301/ejo.5000131 Chen J, Huang H, Wang M, Sun X, Qian S (2012) Fourier domain OCT measurement of macular, macular ganglion cell complex, and peripapillary RNFL thickness in glaucomatous Chinese eyes. Eur J Ophthalmol Mar 20 [Epub ahead of print]. doi:10.​5301/​ejo.​5000131
19.
go back to reference Mok KH, Lee VW, So KF (2004) Retinal nerve fiber loss in high- and normal-tension glaucoma by optical coherence tomography. Optom Vis Sci 81:369–372PubMedCrossRef Mok KH, Lee VW, So KF (2004) Retinal nerve fiber loss in high- and normal-tension glaucoma by optical coherence tomography. Optom Vis Sci 81:369–372PubMedCrossRef
20.
go back to reference Konstantakopoulou E, Reeves BC, Fenerty C, Harper RA (2008) Retinal nerve fiber layer measures in high- and normal-tension glaucoma. Optom Vis Sci 85:538–542PubMedCrossRef Konstantakopoulou E, Reeves BC, Fenerty C, Harper RA (2008) Retinal nerve fiber layer measures in high- and normal-tension glaucoma. Optom Vis Sci 85:538–542PubMedCrossRef
21.
go back to reference Quigley HA, Dunkelberger GR, Green WR (1989) Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma. Am J Ophthalmol 107:453–464PubMed Quigley HA, Dunkelberger GR, Green WR (1989) Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma. Am J Ophthalmol 107:453–464PubMed
22.
go back to reference Medeiros FA, Zangwill LM, Bowd C, Vessani RM, Susanna R Jr, Weinreb RN (2005) Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. Am J Ophthalmol 139:44–55PubMedCrossRef Medeiros FA, Zangwill LM, Bowd C, Vessani RM, Susanna R Jr, Weinreb RN (2005) Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. Am J Ophthalmol 139:44–55PubMedCrossRef
23.
go back to reference Mori S, Hangai M, Sakamoto A, Yoshimura N (2010) Spectral-domain optical coherence tomography measurement of macular volume for diagnosing glaucoma. J Glaucoma 19:528–534PubMedCrossRef Mori S, Hangai M, Sakamoto A, Yoshimura N (2010) Spectral-domain optical coherence tomography measurement of macular volume for diagnosing glaucoma. J Glaucoma 19:528–534PubMedCrossRef
24.
go back to reference Kim NR, Hong S, Kim JH, Rho SS, Seong GJ, Kim CY (2011) Comparison of macular ganglion cell complex thickness by fourier-domain OCT in normal tension glaucoma and primary open-angle glaucoma. J Glaucoma June 22 [Epub ahead of print]. doi:10.1097/IJG.0b013e3182254cde Kim NR, Hong S, Kim JH, Rho SS, Seong GJ, Kim CY (2011) Comparison of macular ganglion cell complex thickness by fourier-domain OCT in normal tension glaucoma and primary open-angle glaucoma. J Glaucoma June 22 [Epub ahead of print]. doi:10.​1097/​IJG.​0b013e3182254cde​
25.
go back to reference Kim NR, Lee ES, Seong GJ, Kang SY, Kim JH, Hong S, Kim CY (2011) Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia. Br J Ophthalmol 95:1115–1121PubMedCrossRef Kim NR, Lee ES, Seong GJ, Kang SY, Kim JH, Hong S, Kim CY (2011) Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia. Br J Ophthalmol 95:1115–1121PubMedCrossRef
26.
go back to reference Kubota T, Khalil AK, Honda M, Ito S, Nishioka Y, Inomata H (1999) Comparative study of retinal nerve fiber layer damage in Japanese patients with normal- and high-tension glaucoma. J Glaucoma 8:363–366PubMedCrossRef Kubota T, Khalil AK, Honda M, Ito S, Nishioka Y, Inomata H (1999) Comparative study of retinal nerve fiber layer damage in Japanese patients with normal- and high-tension glaucoma. J Glaucoma 8:363–366PubMedCrossRef
Metadata
Title
Comparison of ganglion cell and retinal nerve fiber layer thickness in primary open-angle glaucoma and normal tension glaucoma with spectral-domain OCT
Authors
Penpe Gul Firat
Selim Doganay
Ersan Ersin Demirel
Cemil Colak
Publication date
01-03-2013
Publisher
Springer-Verlag
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 3/2013
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-012-2114-5

Other articles of this Issue 3/2013

Graefe's Archive for Clinical and Experimental Ophthalmology 3/2013 Go to the issue