Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 11/2009

01-11-2009 | Refractive Surgery

Comparison of different excimer laser ablation frequencies (50, 200, and 500 Hz)

Authors: C. Winkler von Mohrenfels, R. Khoramnia, C.-P. Lohmann

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 11/2009

Login to get access

Abstract

Purpose

The aim of this study was to compare the influence of different excimer laser (193 nm) ablation frequencies (50, 200, and 500 Hz) on porcine cornea.

Methods

For this study, fresh porcine cadaver eyes were obtained from the butcher. PRK and LASIK were performed using a WaveLight Concept System 500 excimer laser. Various repetition rates (50, 200, and 500 Hz) and intended corrections (between -3 and -9 D) were used. Corneal endothelium was investigated pre- and post-operatively with the endothelial cell microscope EM 1000 Tomey™. Post-operatively, the corneas were embedded for light microscopic (HE, Picrosirius Red) and electron microscopic evaluation.

Results

The mean pre-operative cell count was 2,953 (SD 149) and the mean post-operative cell count was 2,974 (SD 156). There was no difference between the pre- and post-operative cell count and the different ablation frequencies. The distribution of collagen fibers and keratocytes was comparable in all different ablation frequencies. Also, the ultrastructural evaluation of keratocytes and fibers, assessed with transmission electron microscopy, was equal in all three different ablation frequencies.

Conclusions

The endothelial cell density and structural and ultra structural evaluation of the different ablation frequencies (50, 200, 500 Hz) showed no specific side-effects that could be associated with higher repetition rates. The quality of the ablation was comparable in all three different laser ablation frequencies. The 500-Hz excimer laser can provide the same ablation quality as slower platforms, but can also offer the advantage of requiring less treatment time than other laser platforms with lower repetition rates.
Literature
1.
go back to reference Trokel SL, Srinivasan R, Braren B (1983) Excimer laser surgery of the cornea. Am J Ophthalmol 96:710–715PubMed Trokel SL, Srinivasan R, Braren B (1983) Excimer laser surgery of the cornea. Am J Ophthalmol 96:710–715PubMed
2.
go back to reference O'Brart DP, Corbett MC, Lohmann CP, Kerr Muir MG, Marshall J (1995) The effects of ablation diameter on the outcome of excimer laser photorefractive keratectomy. A prospective, randomized, double-blind study. Arch Ophthalmol 113:438–443PubMed O'Brart DP, Corbett MC, Lohmann CP, Kerr Muir MG, Marshall J (1995) The effects of ablation diameter on the outcome of excimer laser photorefractive keratectomy. A prospective, randomized, double-blind study. Arch Ophthalmol 113:438–443PubMed
3.
go back to reference Buratto L, Ferrari M, Genisi C (1993) Myopic keratomileusis with the excimer laser: one-year follow up. Refract Corneal Surg 9:12–19PubMed Buratto L, Ferrari M, Genisi C (1993) Myopic keratomileusis with the excimer laser: one-year follow up. Refract Corneal Surg 9:12–19PubMed
4.
go back to reference Gartry DS, Kerr Muir MG, Marshall J (1991) Photorefractive keratectomy with an argon fluoride excimer laser: a clinical study. Refract Corneal Surg 7:420–435PubMed Gartry DS, Kerr Muir MG, Marshall J (1991) Photorefractive keratectomy with an argon fluoride excimer laser: a clinical study. Refract Corneal Surg 7:420–435PubMed
5.
go back to reference Seiler T (1995) Current evaluation of myopia correction with the excimer laser. Ophthalmologe 92:379–384PubMed Seiler T (1995) Current evaluation of myopia correction with the excimer laser. Ophthalmologe 92:379–384PubMed
7.
go back to reference Durrie DS (2003) First 100 CustomCornea commercial eyes. J Refract Surg 19:S687–S690PubMed Durrie DS (2003) First 100 CustomCornea commercial eyes. J Refract Surg 19:S687–S690PubMed
10.
go back to reference Guell JL, Velasco F (2003) Topographically guided ablations for the correction of irregular astigmatism after corneal surgery. Int Ophthalmol Clin 43:111–128PubMed Guell JL, Velasco F (2003) Topographically guided ablations for the correction of irregular astigmatism after corneal surgery. Int Ophthalmol Clin 43:111–128PubMed
11.
go back to reference Junqueira LC, Bignolas G, Brentani RR (1979) Picrosirius staining plus polarization microscopy, a specific method for collagen detection in tissue sections. Histochem J 11:447–455. doi:10.1007/BF01002772 PubMedCrossRef Junqueira LC, Bignolas G, Brentani RR (1979) Picrosirius staining plus polarization microscopy, a specific method for collagen detection in tissue sections. Histochem J 11:447–455. doi:10.​1007/​BF01002772 PubMedCrossRef
12.
go back to reference Puchtler H, Waldrop FS, Valentine LS (1973) Polarization microscopic studies of connective tissue stained with Picro-sirius Red FBA. Beitr Pathol 150:174–187PubMed Puchtler H, Waldrop FS, Valentine LS (1973) Polarization microscopic studies of connective tissue stained with Picro-sirius Red FBA. Beitr Pathol 150:174–187PubMed
15.
16.
go back to reference Iseli HP, Mrochen M, Hafezi F, Seller T (2004) Clinical photoablation with a 500-Hz scanning spot excimer laser. J Refract Surg 20:831–834PubMed Iseli HP, Mrochen M, Hafezi F, Seller T (2004) Clinical photoablation with a 500-Hz scanning spot excimer laser. J Refract Surg 20:831–834PubMed
Metadata
Title
Comparison of different excimer laser ablation frequencies (50, 200, and 500 Hz)
Authors
C. Winkler von Mohrenfels
R. Khoramnia
C.-P. Lohmann
Publication date
01-11-2009
Publisher
Springer-Verlag
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 11/2009
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-009-1102-x

Other articles of this Issue 11/2009

Graefe's Archive for Clinical and Experimental Ophthalmology 11/2009 Go to the issue