Skip to main content
Top
Published in: International Journal of Legal Medicine 3/2018

01-05-2018 | Original Article

Evaluation of four commercial quantitative real-time PCR kits with inhibited and degraded samples

Authors: Amy S. Holmes, Rachel Houston, Kyleen Elwick, David Gangitano, Sheree Hughes-Stamm

Published in: International Journal of Legal Medicine | Issue 3/2018

Login to get access

Abstract

DNA quantification is a vital step in forensic DNA analysis to determine the optimal input amount for DNA typing. A quantitative real-time polymerase chain reaction (qPCR) assay that can predict DNA degradation or inhibitors present in the sample prior to DNA amplification could aid forensic laboratories in creating a more streamlined and efficient workflow. This study compares the results from four commercial qPCR kits: (1) Investigator® Quantiplex® Pro Kit, (2) Quantifiler® Trio DNA Quantification Kit, (3) PowerQuant® System, and (4) InnoQuant® HY with high molecular weight DNA, low template samples, degraded samples, and DNA spiked with various inhibitors.The results of this study indicate that all kits were comparable in accurately predicting quantities of high quality DNA down to the sub-picogram level. However, the InnoQuant(R) HY kit showed the highest precision across the DNA concentration range tested in this study. In addition, all kits performed similarly with low concentrations of forensically relevant PCR inhibitors. However, in general, the Investigator® Quantiplex® Pro Kit was the most tolerant kit to inhibitors and provided the most accurate quantification results with higher concentrations of inhibitors (except with salt). PowerQuant® and InnoQuant® HY were the most sensitive to inhibitors, but they did indicate significant levels of PCR inhibition. When quantifying degraded samples, each kit provided different degradation indices (DI), with Investigator® Quantiplex® Pro indicating the largest DI and Quantifiler® Trio indicating the smallest DI. When the qPCR kits were paired with their respective STR kit to genotype highly degraded samples, the Investigator® 24plex QS and GlobalFiler® kits generated more complete profiles when the small target concentrations were used for calculating input amount.
Appendix
Available only for authorised users
Literature
2.
3.
go back to reference Loftus A, Murphy G, Brown H, Montgomery A, Tabak J, Baus J, Carroll M, Green A, Sikka S, Sinha S (2017) Development and validation of InnoQuant® HY, a system for quantitation and quality assessment of total human and male DNA using high copy targets. Forensic Sci Int Genet 29:205–217. https://doi.org/10.1016/j.fsigen.2017.04.009 Loftus A, Murphy G, Brown H, Montgomery A, Tabak J, Baus J, Carroll M, Green A, Sikka S, Sinha S (2017) Development and validation of InnoQuant® HY, a system for quantitation and quality assessment of total human and male DNA using high copy targets. Forensic Sci Int Genet 29:205–217. https://​doi.​org/​10.​1016/​j.​fsigen.​2017.​04.​009
4.
go back to reference Pineda GM, Montgomery AH, Thompson R, Indest B, Carroll M, Sinha SK (2014) Development and validation of InnoQuant™, a sensitive human DNA quantitation and degradation assessment method for forensic samples using high copy number mobile elements Alu and SVA. Forensic Sci Int Genet 13:224–235. https://doi.org/10.1016/j.fsigen.2014.08.007 Pineda GM, Montgomery AH, Thompson R, Indest B, Carroll M, Sinha SK (2014) Development and validation of InnoQuant™, a sensitive human DNA quantitation and degradation assessment method for forensic samples using high copy number mobile elements Alu and SVA. Forensic Sci Int Genet 13:224–235. https://​doi.​org/​10.​1016/​j.​fsigen.​2014.​08.​007
5.
go back to reference Di Pasquale F, Cornelius S, König M, Scherer M, Prochnow A, Peist R (2015) Analysis and interpretation of difficult samples—the interaction of a DNA quantification kit with the right STR assay may facilitate processing of critical trace material. Forensic Sci Int Genet Suppl Ser 5:e407–e408. https://doi.org/10.1016/j.fsigss.2015.09.161 Di Pasquale F, Cornelius S, König M, Scherer M, Prochnow A, Peist R (2015) Analysis and interpretation of difficult samples—the interaction of a DNA quantification kit with the right STR assay may facilitate processing of critical trace material. Forensic Sci Int Genet Suppl Ser 5:e407–e408. https://​doi.​org/​10.​1016/​j.​fsigss.​2015.​09.​161
11.
go back to reference Alaeddini R, Walsh SJ, Abbas A (2010) Forensic implications of genetic analyses from degraded DNA—a review. Forensic Sci Int Genet 4(3):148–157. https://doi.org/10.1016/j.fsigen.2009.09.007 Alaeddini R, Walsh SJ, Abbas A (2010) Forensic implications of genetic analyses from degraded DNA—a review. Forensic Sci Int Genet 4(3):148–157. https://​doi.​org/​10.​1016/​j.​fsigen.​2009.​09.​007
14.
go back to reference Alaeddini R (2012) Forensic implications of PCR inhibition—a review. Forensic Sci Int Genet 6(3):297–305. https://doi.org/10.1016/j.fsigen.2011.08.006 Alaeddini R (2012) Forensic implications of PCR inhibition—a review. Forensic Sci Int Genet 6(3):297–305. https://​doi.​org/​10.​1016/​j.​fsigen.​2011.​08.​006
16.
go back to reference Investigator(R) Quantiplex(R) Pro Handbook (April 2017) Investigator(R) Quantiplex(R) Pro Handbook (April 2017)
17.
go back to reference Quantifiler(R) HP and Trio DNA Quantification Kits User Guide (2017) Quantifiler(R) HP and Trio DNA Quantification Kits User Guide (2017)
18.
go back to reference PowerQuant System Technical Manual (March 2015) PowerQuant System Technical Manual (March 2015)
19.
go back to reference InnoQuant(R) HY User Guide v1.5 (Dec. 2016) InnoQuant(R) HY User Guide v1.5 (Dec. 2016)
20.
go back to reference National Institute of Standards & Technology Certificte of Analysis Standard Reference Material (R) 2372 Human DNA Quantification Standard, Issued 1/13 (Jan. 2013) National Institute of Standards & Technology Certificte of Analysis Standard Reference Material (R) 2372 Human DNA Quantification Standard, Issued 1/13 (Jan. 2013)
21.
go back to reference QIAamp(R) DNA Investigator Handbook (June 2012) QIAamp(R) DNA Investigator Handbook (June 2012)
22.
go back to reference PrepFiler(R) and PrepFiler(R) BTA Forensic DNA Extraction Kits User Guide (2012) PrepFiler(R) and PrepFiler(R) BTA Forensic DNA Extraction Kits User Guide (2012)
23.
go back to reference Isolation of DNA from forensic casework samples part B (purification) protocol sheet, version 2 (May 2008) Isolation of DNA from forensic casework samples part B (purification) protocol sheet, version 2 (May 2008)
24.
go back to reference QIAamp(R) DNA FFPE Tissue Handbook (June 2012) QIAamp(R) DNA FFPE Tissue Handbook (June 2012)
25.
go back to reference Investigator(R) 24plex QS Handbook (July 2016) Investigator(R) 24plex QS Handbook (July 2016)
26.
go back to reference GlobalFiler™ PCR Amplification kit user guide (2016) GlobalFiler™ PCR Amplification kit user guide (2016)
27.
go back to reference PowerPlex(R) Fusion 6C System for Use on the Applied Biosystems (R) Genetic Analyzers Technical Manual (April 2017) PowerPlex(R) Fusion 6C System for Use on the Applied Biosystems (R) Genetic Analyzers Technical Manual (April 2017)
Metadata
Title
Evaluation of four commercial quantitative real-time PCR kits with inhibited and degraded samples
Authors
Amy S. Holmes
Rachel Houston
Kyleen Elwick
David Gangitano
Sheree Hughes-Stamm
Publication date
01-05-2018
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Legal Medicine / Issue 3/2018
Print ISSN: 0937-9827
Electronic ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-017-1745-9

Other articles of this Issue 3/2018

International Journal of Legal Medicine 3/2018 Go to the issue