Compatibility of DNA IQ™, QIAamp® DNA Investigator, and QIAsymphony® DNA Investigator® with various fingerprint treatments

Authors: Sze-wah Lin, Stephen C. Y. Ip, Tze-tsun Lam, Tung-fai Tan, Wai-lung Yeung, Wai-ming Tam

Published in: International Journal of Legal Medicine | Issue 2/2017

Login to get access

Abstract

Latent fingerprint and touch DNA are the two most important contact evidence for individualization in forensic science which provide complementary information that can lead to direct and unequivocal identification of the culprit. In order to retrieve useful information from both fingerprints and DNA, which are usually mingled together, one strategy is to perform fingerprint examination prior to DNA analysis since common DNA sampling technique such as swabbing could disturb or even destroy fingerprint details. Here, we describe the compatibility of three automatic DNA extraction systems, namely, DNA IQ™, QIAamp® DNA Investigator, and QIAsymphony® DNA Investigator®, with respective to the effects of various fingerprint detection techniques. Our results demonstrate that Super Glue fingerprint treatment followed by DNA IQ™ extraction shows better effectiveness in DNA profiling. Aluminum powder dusting offers the least interference to the three DNA extraction systems above. Magnetic powder dusting, on the other hand, strongly impedes DNA recovery. Physical Developer is the most intrusive, which yields profiles with poor quality, including lower peak heights, poor peak height ratios, and poor intra-color balance. In terms of the choice of extraction method, DNA IQ™ system is recommended for sampling after fingerprint treatments, but not the two DNA Investigator systems.
Appendix
Available only for authorised users
Literature
2.
go back to reference Andersen J, Bramble S (1997) The effects of fingermark enhancement light sources on subsequent PCR-STR DNA analysis of fresh bloodstains. J Forensic Sci 42:303–306CrossRefPubMed Andersen J, Bramble S (1997) The effects of fingermark enhancement light sources on subsequent PCR-STR DNA analysis of fresh bloodstains. J Forensic Sci 42:303–306CrossRefPubMed
3.
go back to reference Azoury M, Zamir A, Oz C, Wiesner S (2002) The effect of 1,2-indanedione, a latent fingerprint reagent on subsequent DNA profiling. J Forensic Sci 47:586–588PubMed Azoury M, Zamir A, Oz C, Wiesner S (2002) The effect of 1,2-indanedione, a latent fingerprint reagent on subsequent DNA profiling. J Forensic Sci 47:586–588PubMed
4.
go back to reference Balogh MK, Burger J, Bender K, Schneider PM, Alt KW (2003) STR genotyping and mtDNA sequencing of latent fingerprint on paper. Forensic Sci Int 137:188–195CrossRefPubMed Balogh MK, Burger J, Bender K, Schneider PM, Alt KW (2003) STR genotyping and mtDNA sequencing of latent fingerprint on paper. Forensic Sci Int 137:188–195CrossRefPubMed
5.
go back to reference Fregeau CJ, Germain O, Fourney RM (2000) Fingerprint enhancement revisited and the effects of blood enhancement chemicals on subsequent Profiler Plus fluorescent short tandem repeat DNA analysis of fresh and aged bloody fingerprints. J Forensic Sci 45:354–380CrossRefPubMed Fregeau CJ, Germain O, Fourney RM (2000) Fingerprint enhancement revisited and the effects of blood enhancement chemicals on subsequent Profiler Plus fluorescent short tandem repeat DNA analysis of fresh and aged bloody fingerprints. J Forensic Sci 45:354–380CrossRefPubMed
6.
go back to reference Leemans P, Vandeput A, Vanderheyden N, Cassiman JJ, Decorte R (2006) Evaluation of methodology for the isolation and analysis of LCN-DNA before and after dactyloscopic enhancement of fingerprints. Int Congr Ser 1288:583–585. doi:10.1016/j.ics.2005.09.079 CrossRef Leemans P, Vandeput A, Vanderheyden N, Cassiman JJ, Decorte R (2006) Evaluation of methodology for the isolation and analysis of LCN-DNA before and after dactyloscopic enhancement of fingerprints. Int Congr Ser 1288:583–585. doi:10.​1016/​j.​ics.​2005.​09.​079 CrossRef
7.
go back to reference Raymond JJ, Roux C, Pasquier ED, Sutton J, Lennard C (2004) The effect of common fingerprint detection techniques on the DNA typing of fingerprints deposited on different surfaces. Journal of Forensic Identification 54:22–44 Raymond JJ, Roux C, Pasquier ED, Sutton J, Lennard C (2004) The effect of common fingerprint detection techniques on the DNA typing of fingerprints deposited on different surfaces. Journal of Forensic Identification 54:22–44
8.
go back to reference Roux C, Gill K, Sutton J, Lennard C (1999) Further study to investigate the effect of fingerprint enhancement techniques on the DNA analysis of bloodstains. Journal of Forensic Identification 49:357–376 Roux C, Gill K, Sutton J, Lennard C (1999) Further study to investigate the effect of fingerprint enhancement techniques on the DNA analysis of bloodstains. Journal of Forensic Identification 49:357–376
9.
go back to reference Schulz MM, Reichert W (2002) Archived or directly swabbed latent fingerprints as a DNA source for STR typing. Forensic Sci Int 127:128–130CrossRefPubMed Schulz MM, Reichert W (2002) Archived or directly swabbed latent fingerprints as a DNA source for STR typing. Forensic Sci Int 127:128–130CrossRefPubMed
11.
go back to reference Stein C, Kyeck SH, Henssge C (1996) DNA typing of fingerprint reagent treated biological stains. J Forensic Sci 41:1012–1017CrossRefPubMed Stein C, Kyeck SH, Henssge C (1996) DNA typing of fingerprint reagent treated biological stains. J Forensic Sci 41:1012–1017CrossRefPubMed
12.
go back to reference Thamnurak C, Bunakkharasawat W, Suda R, Panvisavas N (2011) DNA typing from fluorescent powder dusted latent fingerprints. Forensic Science International: Genetics Supplement Series 3:e524–e525. doi:10.1016/j.fsigss.2011.10.009 Thamnurak C, Bunakkharasawat W, Suda R, Panvisavas N (2011) DNA typing from fluorescent powder dusted latent fingerprints. Forensic Science International: Genetics Supplement Series 3:e524–e525. doi:10.​1016/​j.​fsigss.​2011.​10.​009
16.
go back to reference Zamir A, Oz C, Geller B (2000) Threat mail and forensic science: DNA profiling from items of evidence after treatment with DFO. J Forensic Sci 45:445–446PubMed Zamir A, Oz C, Geller B (2000) Threat mail and forensic science: DNA profiling from items of evidence after treatment with DFO. J Forensic Sci 45:445–446PubMed
17.
go back to reference Zamir A, Springer E, Glattstein B (2000) Fingerprints and DNA: STR typing of DNA extracted from adhesive tape after processing for fingerprints. J Forensic Sci 45:687–688PubMed Zamir A, Springer E, Glattstein B (2000) Fingerprints and DNA: STR typing of DNA extracted from adhesive tape after processing for fingerprints. J Forensic Sci 45:687–688PubMed
18.
go back to reference Ip SC, Lin SW, Lai KM (2015) An evaluation of the performance of five extraction methods: Chelex® 100, QIAamp® DNA Blood Mini Kit, QIAamp® DNA Investigator Kit, QIAsymphony® DNA Investigator® Kit and DNA IQ. Science & Justice : Journal of the Forensic Science Society 55:200–208. doi:10.1016/j.scijus.2015.01.005 CrossRef Ip SC, Lin SW, Lai KM (2015) An evaluation of the performance of five extraction methods: Chelex® 100, QIAamp® DNA Blood Mini Kit, QIAamp® DNA Investigator Kit, QIAsymphony® DNA Investigator® Kit and DNA IQ. Science & Justice : Journal of the Forensic Science Society 55:200–208. doi:10.​1016/​j.​scijus.​2015.​01.​005 CrossRef
19.
go back to reference Bandey HL (2014) Fingermark Visualisation Manual, Home Office Centre for Applied Science and Technology (CAST), Sandridge, UK Bandey HL (2014) Fingermark Visualisation Manual, Home Office Centre for Applied Science and Technology (CAST), Sandridge, UK
20.
go back to reference Trozzi TA, Schwartz RL, Hollars ML, Leighton LD, Schehi SA, Trozzi YE, Wade C (2000) Processing guide for developing latent prints. US Department of Justice, FBI, Washington, DC Trozzi TA, Schwartz RL, Hollars ML, Leighton LD, Schehi SA, Trozzi YE, Wade C (2000) Processing guide for developing latent prints. US Department of Justice, FBI, Washington, DC
22.
go back to reference van Oorschot RA, Treadwell S, Beaurepaire J, Holding NL, Mitchell RJ (2005) Beware of the possibility of fingerprinting techniques transferring DNA. J Forensic Sci 50:1417–1422PubMed van Oorschot RA, Treadwell S, Beaurepaire J, Holding NL, Mitchell RJ (2005) Beware of the possibility of fingerprinting techniques transferring DNA. J Forensic Sci 50:1417–1422PubMed
Metadata
Title
Compatibility of DNA IQ™, QIAamp® DNA Investigator, and QIAsymphony® DNA Investigator® with various fingerprint treatments
Authors
Sze-wah Lin
Stephen C. Y. Ip
Tze-tsun Lam
Tung-fai Tan
Wai-lung Yeung
Wai-ming Tam
Publication date
01-03-2017
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Legal Medicine / Issue 2/2017
Print ISSN: 0937-9827
Electronic ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-016-1447-8

Other articles of this Issue 2/2017

International Journal of Legal Medicine 2/2017 Go to the issue

Acknowledgement to referees

Acknowledgement to referees