Skip to main content
Top
Published in: International Journal of Legal Medicine 2/2012

01-03-2012 | Case Report

Demonstration of liver metastases on postmortem whole body CT angiography following inadvertent systemic venous infusion of the contrast medium

Authors: Chris O’Donnell, Jacqueline Hislop-Jambrich, Noel Woodford, Melissa Baker

Published in: International Journal of Legal Medicine | Issue 2/2012

Login to get access

Abstract

An 86-year-old woman was hospitalized for breathlessness and a large right-sided pleural effusion. Approximately 1 h after thoracentesis, she developed a hemothorax resulting in hypotension and death. Routine postmortem CT scanning showed a large volume right hemothorax and a markedly enlarged liver. In an attempt to determine the origin of bleeding prior to autopsy, a postmortem CT angiogram was performed. Following inadvertent cannulation of the left long saphenous vein and infusion of ∼1,700 mL of a polyethylene glycol 200 and iodine-based radiographic contrast solution into systemic veins using a mechanical pump, CT scanning revealed a dense hepatic "parenchogram" containing multiple large, filling defects indicative of metastases. These were confirmed at autopsy. Microscopic evaluation of the liver using hematoxylin and eosin staining showed marked histological artifact characterized by centrilobular sinusoidal expansion although histology of the adenocarcinoma metastases was typical and apparently unaffected by the contrast solution. Postmortem CT angiography using an aqueous radiographic contrast agent in the so-called venous phase seems to be useful for the identification of hepatic parenchymal metastatic disease although it does cause histological artifact.
Literature
1.
go back to reference O'Donnell C (2010) An image of sudden death: utility of routine post-mortem computed tomography scanning in medico-legal autopsy practice. Diagn Histopathol 16(12):552–555CrossRef O'Donnell C (2010) An image of sudden death: utility of routine post-mortem computed tomography scanning in medico-legal autopsy practice. Diagn Histopathol 16(12):552–555CrossRef
2.
go back to reference Thali MJ, Jackowski C, Oesterhelweg L, Ross SG, Dirnhofer R (2007) VIRTOPSY—the Swiss virtual autopsy approach. Leg Med (Tokyo) 9(2):100–104CrossRef Thali MJ, Jackowski C, Oesterhelweg L, Ross SG, Dirnhofer R (2007) VIRTOPSY—the Swiss virtual autopsy approach. Leg Med (Tokyo) 9(2):100–104CrossRef
3.
go back to reference Christe A, Flach P, Ross S, Spendlove D, Bolliger S, Vock P, Thali MJ (2010) Clinical radiology and postmortem imaging (Virtopsy) are not the same: specific and unspecific postmortem signs. Leg Med (Tokyo) 12(5):215–222CrossRef Christe A, Flach P, Ross S, Spendlove D, Bolliger S, Vock P, Thali MJ (2010) Clinical radiology and postmortem imaging (Virtopsy) are not the same: specific and unspecific postmortem signs. Leg Med (Tokyo) 12(5):215–222CrossRef
4.
go back to reference Ross S, Spendlove D, Bolliger S, Christe A, Oesterhelweg L, Grabherr S, Thali MJ, Gygax E (2008) Postmortem whole-body CT angiography: evaluation of two contrast media solutions. Am J Roentgenol 190(5):1380–1389CrossRef Ross S, Spendlove D, Bolliger S, Christe A, Oesterhelweg L, Grabherr S, Thali MJ, Gygax E (2008) Postmortem whole-body CT angiography: evaluation of two contrast media solutions. Am J Roentgenol 190(5):1380–1389CrossRef
5.
go back to reference Grabherr S, Doenz F, Steger B, Dirnhofer R, Dominguez A, Sollberger B, Gygax E, Rizzo E, Chevallier C, Meuli R, Mangin P (2010) Multi-phase post-mortem CT angiography: development of a standardized protocol. Int J Legal Med 125(6):791–802PubMedCrossRef Grabherr S, Doenz F, Steger B, Dirnhofer R, Dominguez A, Sollberger B, Gygax E, Rizzo E, Chevallier C, Meuli R, Mangin P (2010) Multi-phase post-mortem CT angiography: development of a standardized protocol. Int J Legal Med 125(6):791–802PubMedCrossRef
6.
go back to reference Bolliger SA, Filograna L, Spendlove D, Thali MJ, Dirnhofer S, Ross S (2010) Postmortem imaging-guided biopsy as an adjuvant to minimally invasive autopsy with CT and postmortem angiography: a feasibility study. AJR Am J Roentgenol 195(5):1051–1056PubMedCrossRef Bolliger SA, Filograna L, Spendlove D, Thali MJ, Dirnhofer S, Ross S (2010) Postmortem imaging-guided biopsy as an adjuvant to minimally invasive autopsy with CT and postmortem angiography: a feasibility study. AJR Am J Roentgenol 195(5):1051–1056PubMedCrossRef
7.
go back to reference Grabherr S, Djonov V, Yen K, Thali MJ, Dirnhofer R (2007) Postmortem angiography: review of former and current methods. Am J Roentgenol 188(3):832–838CrossRef Grabherr S, Djonov V, Yen K, Thali MJ, Dirnhofer R (2007) Postmortem angiography: review of former and current methods. Am J Roentgenol 188(3):832–838CrossRef
8.
go back to reference Grabherr S, Djonov V, Friess A, Thali M, Ranner G, Vock P, Dirnhofer R (2006) Postmortem angiography after vascular perfusion with diesel oil and a lipophilic contrast agent. AJR Am J Roentgenol 187:W515–W523PubMedCrossRef Grabherr S, Djonov V, Friess A, Thali M, Ranner G, Vock P, Dirnhofer R (2006) Postmortem angiography after vascular perfusion with diesel oil and a lipophilic contrast agent. AJR Am J Roentgenol 187:W515–W523PubMedCrossRef
9.
go back to reference Jackowski C, Bolliger S, Aghayev E, Christe A, Kilchoer T, Aebi B, Périnat T, Dirnhofer R, Thali MJ (2006) Reduction of postmortem angiography-induced tissue edema by using polyethylene glycol as a contrast agent dissolver. J Forensic Sci 51(5):1134–1137PubMedCrossRef Jackowski C, Bolliger S, Aghayev E, Christe A, Kilchoer T, Aebi B, Périnat T, Dirnhofer R, Thali MJ (2006) Reduction of postmortem angiography-induced tissue edema by using polyethylene glycol as a contrast agent dissolver. J Forensic Sci 51(5):1134–1137PubMedCrossRef
10.
go back to reference Jackowski C, Persson A, Thali MJ (2008) Whole body postmortem angiography with a high viscosity contrast agent solution using polyethylene glycol as contrast agent dissolver. J Forensic Sci 53(2):465–468PubMedCrossRef Jackowski C, Persson A, Thali MJ (2008) Whole body postmortem angiography with a high viscosity contrast agent solution using polyethylene glycol as contrast agent dissolver. J Forensic Sci 53(2):465–468PubMedCrossRef
11.
go back to reference Foley W, Mallisee T, Hohenwalter M, Wilson C, Quiro F, Taylor A (2000) Multiphase hepatic CT with a multirow detector CT scanner. AJR Am J Roentgenol 175:679–685PubMed Foley W, Mallisee T, Hohenwalter M, Wilson C, Quiro F, Taylor A (2000) Multiphase hepatic CT with a multirow detector CT scanner. AJR Am J Roentgenol 175:679–685PubMed
Metadata
Title
Demonstration of liver metastases on postmortem whole body CT angiography following inadvertent systemic venous infusion of the contrast medium
Authors
Chris O’Donnell
Jacqueline Hislop-Jambrich
Noel Woodford
Melissa Baker
Publication date
01-03-2012
Publisher
Springer-Verlag
Published in
International Journal of Legal Medicine / Issue 2/2012
Print ISSN: 0937-9827
Electronic ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-012-0669-7

Other articles of this Issue 2/2012

International Journal of Legal Medicine 2/2012 Go to the issue