Skip to main content
Top
Published in: International Journal of Legal Medicine 4/2007

01-07-2007 | Original Article

Effects of rounding errors on postmortem temperature measurements caused by thermometer resolution

Authors: Yoshimasa Kanawaku, Jun Kanetake, Atsuki Komiya, Shigenao Maruyama, Masato Funayama

Published in: International Journal of Legal Medicine | Issue 4/2007

Login to get access

Abstract

Beginning 7 h after death, a datalogger was used to measure the temperature in the external auditory canal of an adult male body placed in a refrigerated room. The sequence of measured values approximated a single exponential function with a correlation coefficient of 0.998475. This suggests that the starting time of body cooling in the refrigerated room under constant temperature can be calculated with less error using any two data points recorded by the datalogger. However, the results of such calculations varied widely and longer postmortem intervals demonstrated greater calculation errors. Periodic errors also appeared. Mathematical simulations showed that this variation was caused by rounding errors, which represent the difference between the thermometer readings and the true temperature. The resolution of the thermometer was 0.1°C, a normal specification; however, even this led to noticeable rounding errors. Therefore, significant errors may influence postmortem interval estimations using other body temperatures. When body temperatures are used to determine the time of death, a method that minimizes rounding errors should be considered.
Footnotes
1
The error patterns in Figs. 1a, 2a,b, and d are characterized as the succession of the plot groups shaped “\”. The sizes of these groups are expanded. In this article, the distance from the upper-left point to the lower-right point along the transverse axis is defined as the cycle length and along the vertical axis as the error range (amplitude).
 
Literature
1.
go back to reference James WRL, Knight B (1965) Errors in estimating the time since death. Med Sci Law 5:111–116 James WRL, Knight B (1965) Errors in estimating the time since death. Med Sci Law 5:111–116
2.
go back to reference Kil’diushov EM (2000) Thermometry of cadavers. Sud Med Ekspert 43:3–5 Kil’diushov EM (2000) Thermometry of cadavers. Sud Med Ekspert 43:3–5
3.
go back to reference Henssge C (2002) Accuracy of calculated time since death. In: Knight B (ed) The estimation of the time since death in the early postmortem period, 2nd edn. Arnold, London, pp 96–100 Henssge C (2002) Accuracy of calculated time since death. In: Knight B (ed) The estimation of the time since death in the early postmortem period, 2nd edn. Arnold, London, pp 96–100
4.
go back to reference Henssge C, Beckmann ER, Wischhusen F, Brinkmann B (1984) Determination of the time of death by measurement of central brain temperature. Z Rechtsmed 93:1–22PubMed Henssge C, Beckmann ER, Wischhusen F, Brinkmann B (1984) Determination of the time of death by measurement of central brain temperature. Z Rechtsmed 93:1–22PubMed
5.
go back to reference Henssge C (1979) Precision of estimating the time of death by mathematical expression of rectal body cooling. Z Rechtsmed 83:49–67PubMedCrossRef Henssge C (1979) Precision of estimating the time of death by mathematical expression of rectal body cooling. Z Rechtsmed 83:49–67PubMedCrossRef
6.
go back to reference Mall G, Eisenmenger W (2005) Estimation of time since death by heat-flow finite-element model. Part I: method, model, calibration and validation. Leg Med (Tokyo) 7:1–14 Mall G, Eisenmenger W (2005) Estimation of time since death by heat-flow finite-element model. Part I: method, model, calibration and validation. Leg Med (Tokyo) 7:1–14
7.
go back to reference Mall G, Eisenmenger W (2005) Estimation of time since death by heat-flow finite-element model part II: application to non-standard cooling conditions and preliminary results in practical casework. Leg Med (Tokyo) 7:69–80 Mall G, Eisenmenger W (2005) Estimation of time since death by heat-flow finite-element model part II: application to non-standard cooling conditions and preliminary results in practical casework. Leg Med (Tokyo) 7:69–80
8.
go back to reference Mall G, Eckl M, Sinicina I, Peschel O, Hubig M (2005) Temperature-based death time estimation with only partially known environmental conditions. Int J Legal Med 119:185–194PubMedCrossRef Mall G, Eckl M, Sinicina I, Peschel O, Hubig M (2005) Temperature-based death time estimation with only partially known environmental conditions. Int J Legal Med 119:185–194PubMedCrossRef
9.
go back to reference Henssge C, Althaus L, Bolt J, Freislederer A, Haffner HT, Henssge CA, Hoppe B, Schneider V (2000) Experiences with a compound method for estimating the time since death. I. Rectal temperature nomogram for time since death. Int J Legal Med 113:303–319PubMedCrossRef Henssge C, Althaus L, Bolt J, Freislederer A, Haffner HT, Henssge CA, Hoppe B, Schneider V (2000) Experiences with a compound method for estimating the time since death. I. Rectal temperature nomogram for time since death. Int J Legal Med 113:303–319PubMedCrossRef
10.
go back to reference Henssge C, Madea B (2004) Estimation of the time since death in the early post-mortem period. Forensic Sci Int 144:167–175PubMedCrossRef Henssge C, Madea B (2004) Estimation of the time since death in the early post-mortem period. Forensic Sci Int 144:167–175PubMedCrossRef
11.
go back to reference Nokes L (2002) Double exponential models. In: Knight B (ed) The estimation of the time since death in the early postmortem period, 2nd edn. Arnold, London, pp 17–18 Nokes L (2002) Double exponential models. In: Knight B (ed) The estimation of the time since death in the early postmortem period, 2nd edn. Arnold, London, pp 17–18
12.
go back to reference Marshall TK, Hoare FE (1962) Estimating the time of death. The rectal cooling after death and its mathematical expression. J Forensic Sci 7:56–81 Marshall TK, Hoare FE (1962) Estimating the time of death. The rectal cooling after death and its mathematical expression. J Forensic Sci 7:56–81
13.
go back to reference Bendat JS (1986) Random data analysis and measurement procedures, 2nd edn. Wiley-Interscience, New York, pp 99–106 Bendat JS (1986) Random data analysis and measurement procedures, 2nd edn. Wiley-Interscience, New York, pp 99–106
14.
go back to reference Soumori S, Sato T (2004) Statistics and chemometrics for analytical chemistry, 2nd edn. Kyoritsu, Tokyo, p 4 Soumori S, Sato T (2004) Statistics and chemometrics for analytical chemistry, 2nd edn. Kyoritsu, Tokyo, p 4
15.
go back to reference Parker SP (ed) (2003) McGraw-Hill dictionary of scientific and technical terms. McGraw-Hill, New York, p 13 Parker SP (ed) (2003) McGraw-Hill dictionary of scientific and technical terms. McGraw-Hill, New York, p 13
16.
go back to reference Japanese Standard Association (ed) (2002) Quality control-2002. JIS, Tokyo Japanese Standard Association (ed) (2002) Quality control-2002. JIS, Tokyo
17.
go back to reference Baccino E, De Saint Martin L, Schuliar Y et al (1996) Outer ear temperature and time of death. Forensic Sci Int 83:133–146PubMedCrossRef Baccino E, De Saint Martin L, Schuliar Y et al (1996) Outer ear temperature and time of death. Forensic Sci Int 83:133–146PubMedCrossRef
18.
go back to reference Al-Alousi LM (2002) A study of the shape of the post-mortem cooling curve in 117 forensic cases. Forensic Sci Int 125:237–244PubMedCrossRef Al-Alousi LM (2002) A study of the shape of the post-mortem cooling curve in 117 forensic cases. Forensic Sci Int 125:237–244PubMedCrossRef
19.
go back to reference Hooft P, van de Voorde H (1989) The role of intestinal bacterial heat production in confounding postmortem temperature measurements. Z Rechtsmed 102:331–336PubMedCrossRef Hooft P, van de Voorde H (1989) The role of intestinal bacterial heat production in confounding postmortem temperature measurements. Z Rechtsmed 102:331–336PubMedCrossRef
20.
go back to reference Nokes LD, Hicks B, Knight BH (1985) The post-mortem temperature plateau—fact or fiction? Med Sci Law 25:263–264PubMed Nokes LD, Hicks B, Knight BH (1985) The post-mortem temperature plateau—fact or fiction? Med Sci Law 25:263–264PubMed
21.
go back to reference Shapiro HA (1965) The post-mortem temperature plateau. J Forensic Med 12:137–141PubMed Shapiro HA (1965) The post-mortem temperature plateau. J Forensic Med 12:137–141PubMed
22.
go back to reference Hutchins GM (1985) Body temperature is elevated in the early postmortem period. Hum Pathol 16:560–561PubMedCrossRef Hutchins GM (1985) Body temperature is elevated in the early postmortem period. Hum Pathol 16:560–561PubMedCrossRef
23.
go back to reference Nokes L (2002) Temperature measurement. In: Knight B (ed) The estimation of the time since death in the early postmortem period, 2nd edn. Arnold, London pp 23–25 Nokes L (2002) Temperature measurement. In: Knight B (ed) The estimation of the time since death in the early postmortem period, 2nd edn. Arnold, London pp 23–25
Metadata
Title
Effects of rounding errors on postmortem temperature measurements caused by thermometer resolution
Authors
Yoshimasa Kanawaku
Jun Kanetake
Atsuki Komiya
Shigenao Maruyama
Masato Funayama
Publication date
01-07-2007
Publisher
Springer-Verlag
Published in
International Journal of Legal Medicine / Issue 4/2007
Print ISSN: 0937-9827
Electronic ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-006-0088-8

Other articles of this Issue 4/2007

International Journal of Legal Medicine 4/2007 Go to the issue