Skip to main content
Top
Published in: European Archives of Oto-Rhino-Laryngology 2/2017

01-02-2017 | Otology

An observational, prospective study to evaluate the preoperative planning tool “CI-Wizard” for cochlear implant surgery

Authors: Markus Pirlich, Mary Tittmann, Daniela Franz, Andreas Dietz, Mathias Hofer

Published in: European Archives of Oto-Rhino-Laryngology | Issue 2/2017

Login to get access

Abstract

“CI-Wizard” is a new, three-dimensional software planning tool for cochlear implant surgery with manual and semi-automatic algorithms to visualize anatomical risk structures of the lateral skull base preoperatively. Primary endpoints of the study represented the evaluation of the CI-Wizards usability, accuracy, subjectively perceived and objectively measured time in clinical practice. In a period from January 2014 to March 2015, n = 36 participants were included in this study. These members were divided into three groups of equal number (n = 12), but different level of experience. Senior doctors and consultants (group 1), residents (group 2) and medical students (group 3) segmented 12 different CT-scan data sets of the CI-Wizard (four per participant). In total, n = 144 data sets were collected. The usability of the CI-Wizard was measured by the given questionnaire with an interval rating scale. The Jaccard coefficient (JT) was used to evaluate the accuracy of the anatomical structures segmented. The subjectively perceived time was measured with an interval rating scale in the questionnaire and was compared with the objectively mean measured time (time interact). Across all three groups, the usability of the CI-Wizard has been assessed between 1 (“very good”) and 2 (“with small defects”). Subjectively, the time was stated as “appropriate” by questionnaire. Objective measurements of the required duration revealed averages of t = 9.8 min for creating a target view. Concerning the accuracy, semi-automatic anatomical structures such as the external acoustic canal (JT = 0.90), the tympanic cavity (JT = 0.87), the ossicles (JT = 0.63), the cochlea (JT = 0.66), and the semicircular canals (JT = 0.61) reached high Jaccard values, which describes a great match of the segmented structures between the partcipants and the gold standard. Facial nerve (JT = 0.39) and round window (JT = 0.37) reached lower Jaccard values. Very little overlap tendency was found for the chorda tympani (JT = 0.11). This software program represents a further important step in the development of preoperative planning tools in cochlear implant surgery. The study revealed a high level of satisfaction in the usability. The subjectively required time was considered as “appropriate” and the objectively mean measured time was t = 9.8 min short enough, so that a clinical application seems realistic. Particularly for semi-automatically segmented structures, it represented a good accuracy. For purely manual segmented structures, further improvements are desirable. Finally, this program also provides a good learning tool for medical students and residents to become familiar with the anatomy of the lateral skull base.
Literature
1.
go back to reference Howard JD, Elster AD, May JS (1990) Temporal bone: three dimensional CT. I. Normal anatomy, techniques and limitations. Radiology 177:421–425CrossRefPubMed Howard JD, Elster AD, May JS (1990) Temporal bone: three dimensional CT. I. Normal anatomy, techniques and limitations. Radiology 177:421–425CrossRefPubMed
2.
go back to reference Ali QM, Ulrich C, Becker H (1993) Three-dimensional CT of the middle ear and adjacent structures. Neuroradiology 35:238–241CrossRefPubMed Ali QM, Ulrich C, Becker H (1993) Three-dimensional CT of the middle ear and adjacent structures. Neuroradiology 35:238–241CrossRefPubMed
3.
go back to reference Rodt Ratiu, Becker Bartling, Kacher Anderson, Jolesz Kikinis (2002) 3D visualisation of the middle ear and adjacent structures using reconstructed multi-slice CT datasets, correlating 3D images and virtual endoscopy tot he 2D cross-sectional images. Neuroradiology 44:783–790CrossRefPubMed Rodt Ratiu, Becker Bartling, Kacher Anderson, Jolesz Kikinis (2002) 3D visualisation of the middle ear and adjacent structures using reconstructed multi-slice CT datasets, correlating 3D images and virtual endoscopy tot he 2D cross-sectional images. Neuroradiology 44:783–790CrossRefPubMed
4.
go back to reference Howard JD, Elster AD, May JS (1990) Temporal bone: three-dimensional CT. II. Pathologic alterations. Radiology 177:427–430PubMed Howard JD, Elster AD, May JS (1990) Temporal bone: three-dimensional CT. II. Pathologic alterations. Radiology 177:427–430PubMed
5.
go back to reference Hermans R, Marchal G, Feenestra L, Baert AL (1995) Spiral CT of the temporal bone: value of image reconstruction at submillimetric table increments. Neuroradiology 37:150–154CrossRefPubMed Hermans R, Marchal G, Feenestra L, Baert AL (1995) Spiral CT of the temporal bone: value of image reconstruction at submillimetric table increments. Neuroradiology 37:150–154CrossRefPubMed
6.
go back to reference Ferreira A, Gentil F, Tavares JM (2014) Segmentation algorithms for ear image data towards biomechanical studies. Comp Methods Biomech Bio Eng 17:888–904CrossRef Ferreira A, Gentil F, Tavares JM (2014) Segmentation algorithms for ear image data towards biomechanical studies. Comp Methods Biomech Bio Eng 17:888–904CrossRef
7.
go back to reference Gerber N, Bell B, Gavaghan K, Weisstanner C, Caversaccio M, Weber S (2014) Surgical planning tool for robotically assisted hearing aid implantation. Int J CARS 9:11–20CrossRef Gerber N, Bell B, Gavaghan K, Weisstanner C, Caversaccio M, Weber S (2014) Surgical planning tool for robotically assisted hearing aid implantation. Int J CARS 9:11–20CrossRef
8.
go back to reference Marro A, Bandukwala T, Mak W (2015) Three-dimensional printing and medical imaging: a review of the methods and applications. Curr Probl Diagn Radiol 112–117 Marro A, Bandukwala T, Mak W (2015) Three-dimensional printing and medical imaging: a review of the methods and applications. Curr Probl Diagn Radiol 112–117
9.
go back to reference Ma Zhen, Tavares JM, Jorge RN, Mascarenhas T (2010) A review of algorithms for medical image segmentation and their applications to the female pelvic cavity. Comp Methods Biomech Bio Eng 13(2):235–246CrossRef Ma Zhen, Tavares JM, Jorge RN, Mascarenhas T (2010) A review of algorithms for medical image segmentation and their applications to the female pelvic cavity. Comp Methods Biomech Bio Eng 13(2):235–246CrossRef
10.
go back to reference Anderson JR, Barrett SF (2007) A quantitative comparison between manual segmentation and threshold-based segmentation of CLSM recorded images. Biomed Sci Instrum 43:290–295PubMed Anderson JR, Barrett SF (2007) A quantitative comparison between manual segmentation and threshold-based segmentation of CLSM recorded images. Biomed Sci Instrum 43:290–295PubMed
11.
go back to reference Sartoretti-Schefer S, Kollias S, Wichmann W, Valavanis A (1998) T2-weighted three-dimensional fast spin-echo MR in inflammatory peripheral facial nerve palsy. Am J Neuroradiol 19:491–495PubMed Sartoretti-Schefer S, Kollias S, Wichmann W, Valavanis A (1998) T2-weighted three-dimensional fast spin-echo MR in inflammatory peripheral facial nerve palsy. Am J Neuroradiol 19:491–495PubMed
12.
13.
go back to reference Braun K, Böhnke F, Stark T (2012) Three-dimensional representation of the human cochlea using micro-computed tomography data: presenting an anatomical model for further numerical calculations. Acta Otolaryngol 132:603–613CrossRefPubMed Braun K, Böhnke F, Stark T (2012) Three-dimensional representation of the human cochlea using micro-computed tomography data: presenting an anatomical model for further numerical calculations. Acta Otolaryngol 132:603–613CrossRefPubMed
14.
go back to reference Kisser U, Ertl-Wagner B, Hempel JM, Müller J, D`Anastasi S, Anderson-Kisser C, Laubender R, Stelter K, Braun C, Pomschar A (2014) High-resolution computed tomography-based length assessments of the cochlea—an accuracy evaluation. Acta Oto-Laryngogica 134:1011–1015CrossRef Kisser U, Ertl-Wagner B, Hempel JM, Müller J, D`Anastasi S, Anderson-Kisser C, Laubender R, Stelter K, Braun C, Pomschar A (2014) High-resolution computed tomography-based length assessments of the cochlea—an accuracy evaluation. Acta Oto-Laryngogica 134:1011–1015CrossRef
15.
go back to reference Majdani O, Rau T, Baron S, Eilers H, Baier C, Heimann B, Ortmaier T, Bartling S, Lenarz T, Leinung M (2009) A robot-guided minimally invasive approach for cochlear implant surgery: preliminary results of a temporal bone study. Int J Proc Comp Assist Radiol Surg 4(5):475–486CrossRef Majdani O, Rau T, Baron S, Eilers H, Baier C, Heimann B, Ortmaier T, Bartling S, Lenarz T, Leinung M (2009) A robot-guided minimally invasive approach for cochlear implant surgery: preliminary results of a temporal bone study. Int J Proc Comp Assist Radiol Surg 4(5):475–486CrossRef
16.
go back to reference Todt I, Lamecker H, Ramm H, Ernst A (2014) A computed tomographic data-based vibrant bonebridge visualization tool. Cochlear Implants Int 15(1):72–74CrossRef Todt I, Lamecker H, Ramm H, Ernst A (2014) A computed tomographic data-based vibrant bonebridge visualization tool. Cochlear Implants Int 15(1):72–74CrossRef
17.
go back to reference Frauenberger C, Stockman T, Putz V, Höldrich, R (2005) Mode independent interaction pattern design. Ninth International Conference on Information Visualisation (IV`05):24–30 Frauenberger C, Stockman T, Putz V, Höldrich, R (2005) Mode independent interaction pattern design. Ninth International Conference on Information Visualisation (IV`05):24–30
18.
go back to reference Schubert O, Sartor K, Forsting M, Reisser C (1996) Three-dimensional computed display of otosurgical operation sites by spiral CT. Neuroradiology 38:663–668CrossRefPubMed Schubert O, Sartor K, Forsting M, Reisser C (1996) Three-dimensional computed display of otosurgical operation sites by spiral CT. Neuroradiology 38:663–668CrossRefPubMed
19.
go back to reference Bielamowicz SA, Coker NJ, Jenkins HA et al (1988) Surgical dimensions of the facial recess in adults and children. Arch Otolaryngol Head Neck Surg 114:534–537CrossRefPubMed Bielamowicz SA, Coker NJ, Jenkins HA et al (1988) Surgical dimensions of the facial recess in adults and children. Arch Otolaryngol Head Neck Surg 114:534–537CrossRefPubMed
20.
go back to reference Su WY, Marion MS, Hinojosa R et al (1982) Anatomical measurements of the cochlear aqueduct, round window membrane, round window niche and facial recess. Laryngoscope 92:483–486CrossRefPubMed Su WY, Marion MS, Hinojosa R et al (1982) Anatomical measurements of the cochlear aqueduct, round window membrane, round window niche and facial recess. Laryngoscope 92:483–486CrossRefPubMed
21.
go back to reference Adunka OF, Radeloff A, Gstoettner WK et al (2007) Scala tympani cochleostomy II: topographie and histology. Laryngoscope 117:2195–2200CrossRefPubMed Adunka OF, Radeloff A, Gstoettner WK et al (2007) Scala tympani cochleostomy II: topographie and histology. Laryngoscope 117:2195–2200CrossRefPubMed
22.
go back to reference Roland PS, Wright CG, Isaacson B (2007) Cochlear implant electrode insertion: the round window revisited. Laryngoscope 117:1397–1402CrossRefPubMed Roland PS, Wright CG, Isaacson B (2007) Cochlear implant electrode insertion: the round window revisited. Laryngoscope 117:1397–1402CrossRefPubMed
23.
go back to reference Schipper J, Klenzer T, Aschendorff A et al (2004) Navigation-controlled cochleostomy. −Is an improvement in the quality of results for chochlear implant surgery possible? HNO 52:329–335CrossRefPubMed Schipper J, Klenzer T, Aschendorff A et al (2004) Navigation-controlled cochleostomy. −Is an improvement in the quality of results for chochlear implant surgery possible? HNO 52:329–335CrossRefPubMed
24.
go back to reference Jaccard P (1912) The distribution of the flora in the alpin zone. New Phytol 11(2):37–50CrossRef Jaccard P (1912) The distribution of the flora in the alpin zone. New Phytol 11(2):37–50CrossRef
25.
go back to reference Todeschini R, Consonni V, Xiang H, Holliday J, Buscema M, Willett P (2012) Similarity coefficients for binary chemoinformatics data: overview and extended comparison using simulated and real data sets. J Chem Inf Model 52:2884–2901CrossRefPubMed Todeschini R, Consonni V, Xiang H, Holliday J, Buscema M, Willett P (2012) Similarity coefficients for binary chemoinformatics data: overview and extended comparison using simulated and real data sets. J Chem Inf Model 52:2884–2901CrossRefPubMed
26.
27.
go back to reference Jun BC, Song SW, Cho JE, Park CS, Lee DH, Chang KH, Yeo SW (2005) Three-dimensional reconstruction based on images from spiral high-resolution computed tomography of the temporal bone: anatomy and clinical appilcation. J Laryngol Otol 119(9):693–698CrossRefPubMed Jun BC, Song SW, Cho JE, Park CS, Lee DH, Chang KH, Yeo SW (2005) Three-dimensional reconstruction based on images from spiral high-resolution computed tomography of the temporal bone: anatomy and clinical appilcation. J Laryngol Otol 119(9):693–698CrossRefPubMed
28.
go back to reference Noble JH, Warren FM, Labadie RF, Dawant BM (2008) Automatic segmentation of the facial nerve and the chorda tympani in CT images using spatially dependent feature values. Am Assoc Physicists Med 35(12):5375–5384 Noble JH, Warren FM, Labadie RF, Dawant BM (2008) Automatic segmentation of the facial nerve and the chorda tympani in CT images using spatially dependent feature values. Am Assoc Physicists Med 35(12):5375–5384
29.
go back to reference Hubálek Z (1982) Coefficients of association and similarity, based on binary (presence-absence) data: an evalutation. Biol Rev 57:669–689CrossRef Hubálek Z (1982) Coefficients of association and similarity, based on binary (presence-absence) data: an evalutation. Biol Rev 57:669–689CrossRef
30.
go back to reference Kanitsar A, Fleischmann D, Wegenkittl R, Felkel P, Gröller ME (2002) CPR-curved planar reformation. IEEE Visual VIS 2002:37–44 Kanitsar A, Fleischmann D, Wegenkittl R, Felkel P, Gröller ME (2002) CPR-curved planar reformation. IEEE Visual VIS 2002:37–44
31.
go back to reference Noble JH, Dawant BM (2011) An atlas-navigated optimal medial axis and deformable model algorithm (NOMAD) for segmentation of the optic nerves and chiasm in MR and CT images. Med Image Anal 15(6):877–884CrossRefPubMedPubMedCentral Noble JH, Dawant BM (2011) An atlas-navigated optimal medial axis and deformable model algorithm (NOMAD) for segmentation of the optic nerves and chiasm in MR and CT images. Med Image Anal 15(6):877–884CrossRefPubMedPubMedCentral
Metadata
Title
An observational, prospective study to evaluate the preoperative planning tool “CI-Wizard” for cochlear implant surgery
Authors
Markus Pirlich
Mary Tittmann
Daniela Franz
Andreas Dietz
Mathias Hofer
Publication date
01-02-2017
Publisher
Springer Berlin Heidelberg
Published in
European Archives of Oto-Rhino-Laryngology / Issue 2/2017
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-016-4286-9

Other articles of this Issue 2/2017

European Archives of Oto-Rhino-Laryngology 2/2017 Go to the issue