Skip to main content
Top
Published in: European Archives of Oto-Rhino-Laryngology 2/2016

01-02-2016 | Otology

Neutral position of persistent direction-changing positional nystagmus

Author: Hiroaki Ichijo

Published in: European Archives of Oto-Rhino-Laryngology | Issue 2/2016

Login to get access

Abstract

The aim of this study was to measure the neutral position of direction-changing apogeotropic positional nystagmus (heavy cupula of the horizontal semicircular canal) and persistent direction-changing geotropic positional nystagmus (light cupula of the horizontal semicircular canal). We conducted a prospective case series study on 31 patients with heavy cupula (12 males, 19 females; mean age, 64.3 years) and 33 patients with light cupula (10 males, 23 females; mean age, 60.9 years). We measured the angle of the neutral position in patients with heavy cupula (θ 1) and that in patients with light cupula (θ 2) using a large protractor. The mean value and standard deviation of θ 1 was 31.6 ± 22.4°, minimum value was 5°, and maximum value was 89°. The mean value and standard deviation of θ 2 was 44.4 ± 20.5°, minimum value was 5°, and maximum value was 85°. θ 2 was significantly greater than θ 1 (p < 0.05). The neutral position varies widely. Some patients exhibit a great angle (more than 40°); therefore, examiners should make patients adopt a completely lateral position in the supine head roll test and should confirm the direction of nystagmus in order to avoid mistaking positional nystagmus for spontaneous nystagmus.
Literature
1.
go back to reference Imai T, Ito M, Takeda N, et al (2005) Natural course of the remission of vertigo in patients with benign paroxysmal positional vertigo. Neurology 64:920–921 Imai T, Ito M, Takeda N, et al (2005) Natural course of the remission of vertigo in patients with benign paroxysmal positional vertigo. Neurology 64:920–921
2.
go back to reference Baloh RW, Yue Q, Jacobson KM, Honrubia V (1995) Persistent direction-changing positional nystagmus: another variant of benign positional nystagmus? Neurology 45:1297–1301PubMedCrossRef Baloh RW, Yue Q, Jacobson KM, Honrubia V (1995) Persistent direction-changing positional nystagmus: another variant of benign positional nystagmus? Neurology 45:1297–1301PubMedCrossRef
3.
go back to reference Bisdorff AR, Debatisse D (2001) Localizing signs in positional vertigo due to lateral canal cupulolithiasis. Neurology 57:1085–1088PubMedCrossRef Bisdorff AR, Debatisse D (2001) Localizing signs in positional vertigo due to lateral canal cupulolithiasis. Neurology 57:1085–1088PubMedCrossRef
4.
go back to reference Baloh RW, Jacobson K, Honrubia V (1993) Horizontal semicircular canal variant of benign positional vertigo. Neurology 43:2542–2549PubMedCrossRef Baloh RW, Jacobson K, Honrubia V (1993) Horizontal semicircular canal variant of benign positional vertigo. Neurology 43:2542–2549PubMedCrossRef
5.
6.
go back to reference Hiruma K, Numata T (2004) Positional nystagmus showing neutral points. ORL J 66:46–50CrossRef Hiruma K, Numata T (2004) Positional nystagmus showing neutral points. ORL J 66:46–50CrossRef
7.
go back to reference Bergenius J, Tomanovic T (2006) Persistent geotropic nystagmus–a different kind of cupular pathology and its localizing signs. Acta Otolaryngol 126:698–704PubMedCrossRef Bergenius J, Tomanovic T (2006) Persistent geotropic nystagmus–a different kind of cupular pathology and its localizing signs. Acta Otolaryngol 126:698–704PubMedCrossRef
8.
go back to reference Ichijo H (2012) Persistent direction-changing geotropic positional nystagmus. Eur Arch Otorhinolaryngol 269:747–751PubMedCrossRef Ichijo H (2012) Persistent direction-changing geotropic positional nystagmus. Eur Arch Otorhinolaryngol 269:747–751PubMedCrossRef
9.
go back to reference Kim CH, Kim MB, Ban JH (2014) Persistent geotropic direction-changing positional nystagmus with a null plane: the light cupula. Laryngoscope 124:15–19CrossRef Kim CH, Kim MB, Ban JH (2014) Persistent geotropic direction-changing positional nystagmus with a null plane: the light cupula. Laryngoscope 124:15–19CrossRef
10.
go back to reference Hiruma K, Numata T, Mitsuhashi T et al (2011) Two types of direction-changing positional nystagmus with neutral points. Auris Nasus Larynx 38:46–51PubMedCrossRef Hiruma K, Numata T, Mitsuhashi T et al (2011) Two types of direction-changing positional nystagmus with neutral points. Auris Nasus Larynx 38:46–51PubMedCrossRef
11.
12.
go back to reference Bradshaw AP, Curthoys IS, Todd MJ et al (2010) A mathematical model of human semicircular canal geometry: a new basis for interpreting vestibular physiology. J Assoc Res Otolaryngol 11:145–159PubMedPubMedCentralCrossRef Bradshaw AP, Curthoys IS, Todd MJ et al (2010) A mathematical model of human semicircular canal geometry: a new basis for interpreting vestibular physiology. J Assoc Res Otolaryngol 11:145–159PubMedPubMedCentralCrossRef
13.
go back to reference Ichijo H (2002) Angles between left and right vertical semicircular canals. Nihon JibiinkokaGakkaiKaiho 105:1138–1142 Ichijo H (2002) Angles between left and right vertical semicircular canals. Nihon JibiinkokaGakkaiKaiho 105:1138–1142
14.
go back to reference Della Santina CC, Potyagaylo V, Migliaccio AA et al (2005) Orientation of human semicircular canals measured by three-dimensional multiplanar CT reconstruction. J Assoc Res Otolaryngol 6:191–206PubMedPubMedCentralCrossRef Della Santina CC, Potyagaylo V, Migliaccio AA et al (2005) Orientation of human semicircular canals measured by three-dimensional multiplanar CT reconstruction. J Assoc Res Otolaryngol 6:191–206PubMedPubMedCentralCrossRef
15.
go back to reference Yamane H, Igarashi M (1984) Free-floating cells in the endolymphatic sac after surgical utricular nerve section. ORL J 46:289–293CrossRef Yamane H, Igarashi M (1984) Free-floating cells in the endolymphatic sac after surgical utricular nerve section. ORL J 46:289–293CrossRef
Metadata
Title
Neutral position of persistent direction-changing positional nystagmus
Author
Hiroaki Ichijo
Publication date
01-02-2016
Publisher
Springer Berlin Heidelberg
Published in
European Archives of Oto-Rhino-Laryngology / Issue 2/2016
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-014-3487-3

Other articles of this Issue 2/2016

European Archives of Oto-Rhino-Laryngology 2/2016 Go to the issue