Skip to main content
Top
Published in: European Archives of Oto-Rhino-Laryngology 1/2010

01-01-2010 | Otology

Magnet displacement: a rare complication following cochlear implantation

Authors: Corina Wild, John Allum, Rudolf Probst, Daniel Abels, Claude Fischer, Daniel Bodmer

Published in: European Archives of Oto-Rhino-Laryngology | Issue 1/2010

Login to get access

Abstract

The purpose of this paper is to describe cases which reported complication after cochlear implantation in children: displacement of magnet from the receiver pocket, possibly aided by the use of magnetic toys. We observed magnet displacement in two female children from the same family and in one male child. Age at implantation was 23, 51, and 24 months, respectively. Magnet displacement occurred at 37, 16, and 32 months, respectively after the initial surgery. The magnets were replaced under general anaesthesia and we did not observe recurrent magnet dislodgement. Measurements indicated that forces required to remove the magnet from its pocket were not greater than those exerted by magnetic toys or the magnet used in the external sender coil. Although magnet displacement is not common after cochlear implantation, it is a major complication in children where subsequent general anaesthesia and surgery are necessary to replace the magnet. Therefore, we propose that pockets for removable magnets of cochlear implants used in children should be redesigned to increase forces to remove the magnet or that removable magnets not be used at all.
Literature
1.
go back to reference Cohen NL, Hofman RA (1991) Complications of cochlear implant surgery in adults and children. Ann Otol Rhinol Laryngol 100:708–711PubMed Cohen NL, Hofman RA (1991) Complications of cochlear implant surgery in adults and children. Ann Otol Rhinol Laryngol 100:708–711PubMed
3.
go back to reference Proops DW, Stoddart RL, Donaldson I (1999) Medical, surgical and audiological complications of the first 100 adult cochlear implant patients in Birmingham. J Laryngol Otol 113:14–17 Proops DW, Stoddart RL, Donaldson I (1999) Medical, surgical and audiological complications of the first 100 adult cochlear implant patients in Birmingham. J Laryngol Otol 113:14–17
4.
go back to reference Nichani JR, Broomfield SJ, Saeed SR (2004) Displacement of the magnet of a cochlear implant receiver stimulator package following minor head trauma. Cochlear Implants Int 5(3):105–111. doi:10.1002/cii.134 CrossRefPubMed Nichani JR, Broomfield SJ, Saeed SR (2004) Displacement of the magnet of a cochlear implant receiver stimulator package following minor head trauma. Cochlear Implants Int 5(3):105–111. doi:10.​1002/​cii.​134 CrossRefPubMed
6.
go back to reference Stokroos RJ, van Dijk P (2007) Migration of cochlear implant magnets after head trauma in an adult and a child. Ear Nose Throat J 86(10):612–613PubMed Stokroos RJ, van Dijk P (2007) Migration of cochlear implant magnets after head trauma in an adult and a child. Ear Nose Throat J 86(10):612–613PubMed
7.
go back to reference Migirov L, Muchnik C, Kaplan-Neeman R, Kronenberg J (2006) Surgical and medical complications in paediatric cochlear implantation : a review of 300 cases. Cochlear Implants Int 7(4):194–201. doi:10.1002/cii.319 CrossRefPubMed Migirov L, Muchnik C, Kaplan-Neeman R, Kronenberg J (2006) Surgical and medical complications in paediatric cochlear implantation : a review of 300 cases. Cochlear Implants Int 7(4):194–201. doi:10.​1002/​cii.​319 CrossRefPubMed
Metadata
Title
Magnet displacement: a rare complication following cochlear implantation
Authors
Corina Wild
John Allum
Rudolf Probst
Daniel Abels
Claude Fischer
Daniel Bodmer
Publication date
01-01-2010
Publisher
Springer-Verlag
Published in
European Archives of Oto-Rhino-Laryngology / Issue 1/2010
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-009-1017-5

Other articles of this Issue 1/2010

European Archives of Oto-Rhino-Laryngology 1/2010 Go to the issue