01-08-2009 | Miscellaneous

The impact of the microphone position on the frequency analysis of snoring sounds

Authors: Michael Herzog, Thomas Kühnel, Thomas Bremert, Beatrice Herzog, Werner Hosemann, Holger Kaftan

Published in: European Archives of Oto-Rhino-Laryngology | Issue 8/2009

Login to get access

Abstract

Frequency analysis of snoring sounds has been reported as a diagnostic tool to differentiate between different sources of snoring. Several studies have been published presenting diverging results of the frequency analyses of snoring sounds. Depending on the position of the used microphones, the results of the frequency analysis of snoring sounds vary. The present study investigated the influence of different microphone positions on the outcome of the frequency analysis of snoring sounds. Nocturnal snoring was recorded simultaneously at six positions (air-coupled: 30 cm middle, 100 cm middle, 30 cm lateral to both sides of the patients’ head; body contact: neck and parasternal) in five patients. The used microphones had a flat frequency response and a similar frequency range (10/40 Hz–18 kHz). Frequency analysis was performed by fast Fourier transformation and frequency bands as well as peak intensities (Peaks 1–5) were detected. Air-coupled microphones presented a wider frequency range (60 Hz–10 kHz) compared to contact microphones. The contact microphone at cervical position presented a cut off at frequencies above 300 Hz, whereas the contact microphone at parasternal position revealed a cut off above 100 Hz. On an exemplary base, the study demonstrates that frequencies above 1,000 Hz do appear in complex snoring patterns, and it is emphasised that high frequencies are imported for the interpretation of snoring sounds with respect to the identification of the source of snoring. Contact microphones might be used in screening devices, but for a natural analysis of snoring sounds the use of air-coupled microphones is indispensable.
Literature
3.
go back to reference Caffier PP, Berl JC, Muggli A, Reinhardt A, Jakob A, Moser M, Fietze I, Scherer H, Holzl M (2007) Snoring noise pollution—the need for objective quantification of annoyance, regulatory guidelines and mandatory therapy for snoring. Physiol Meas 28:25–40. doi:10.1088/0967-3334/28/1/003 CrossRefPubMed Caffier PP, Berl JC, Muggli A, Reinhardt A, Jakob A, Moser M, Fietze I, Scherer H, Holzl M (2007) Snoring noise pollution—the need for objective quantification of annoyance, regulatory guidelines and mandatory therapy for snoring. Physiol Meas 28:25–40. doi:10.​1088/​0967-3334/​28/​1/​003 CrossRefPubMed
12.
14.
go back to reference Perez-Padilla JR, Slawinski E, Difrancesco LM, Feige RR, Remmers JE, Whitelaw WA (1993) Characteristics of the snoring noise in patients with and without occlusive sleep apnea. Am Rev Respir Dis 147:635–644CrossRefPubMed Perez-Padilla JR, Slawinski E, Difrancesco LM, Feige RR, Remmers JE, Whitelaw WA (1993) Characteristics of the snoring noise in patients with and without occlusive sleep apnea. Am Rev Respir Dis 147:635–644CrossRefPubMed
16.
go back to reference Rembold CM, Suratt PM (2004) Children with obstructive sleep-disordered breathing generate high-frequency inspiratory sounds during sleep. Sleep 27:1154–1161CrossRefPubMed Rembold CM, Suratt PM (2004) Children with obstructive sleep-disordered breathing generate high-frequency inspiratory sounds during sleep. Sleep 27:1154–1161CrossRefPubMed
18.
19.
go back to reference Sola-Soler J, Jane R, Fiz JA, Morera J (2007) Automatic classification of subjects with and without sleep apnea through snoring analysis. Conf Proc IEEE Eng Med Biol Soc 1:6093–6096. doi:10.1109/IEMBS.2007.4353739 Sola-Soler J, Jane R, Fiz JA, Morera J (2007) Automatic classification of subjects with and without sleep apnea through snoring analysis. Conf Proc IEEE Eng Med Biol Soc 1:6093–6096. doi:10.​1109/​IEMBS.​2007.​4353739
20.
go back to reference Sola-Soler J, Jane R, Fiz JA, Morera J (2005) Variability of snore parameters in time and frequency domains in snoring subjects with and without obstructive sleep apnea. Conf Proc IEEE Eng Med Biol Soc 3:2583–2586PubMed Sola-Soler J, Jane R, Fiz JA, Morera J (2005) Variability of snore parameters in time and frequency domains in snoring subjects with and without obstructive sleep apnea. Conf Proc IEEE Eng Med Biol Soc 3:2583–2586PubMed
Metadata
Title
The impact of the microphone position on the frequency analysis of snoring sounds
Authors
Michael Herzog
Thomas Kühnel
Thomas Bremert
Beatrice Herzog
Werner Hosemann
Holger Kaftan
Publication date
01-08-2009
Publisher
Springer Berlin Heidelberg
Published in
European Archives of Oto-Rhino-Laryngology / Issue 8/2009
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-008-0858-7

Other articles of this Issue 8/2009

European Archives of Oto-Rhino-Laryngology 8/2009 Go to the issue