The objective of this study was to assess the influence of a cochlear implant (CI) on horizontal semicircular canal (hSCC) function, to test the correlation with symptomatic vertigo and to identify possible risk factors for a postoperative vestibular impairment. In a prospective observational study design, forty-seven adult patients who had undergone cochlear implantation at Cochlear Implant Center at a tertiary referral university hospital, Munich, between 2003 and 2007, were studied. Postoperative vertigo symptoms were assessed using a questionnaire followed by a structured interview. Patients were subjected to caloric and rotational chair vestibular function tests pre- and postoperatively. The CI operation was performed with a retroauricular transmastoidal approach by three different surgeons. Thirty-six implants were Cochlear Nucleus 24 devices and 11 implants were MedEl devices. Twenty-one (45%) patients reported vertigo symptoms after CI. Functional testing of the hSCC yielded valid results in 45 of the 47 patients. Thirty-two percent of patients had a substantially reduced hSCC function after CI. Responses of caloric irrigation showed a significant worsening postoperatively in the CI ears. No direct correlation between a decrease in caloric response and risk of postoperative vertigo symptoms could be established. For the criteria age, sex, implant type, surgeon, cause of deafness, petrous bone CT findings and preoperative vertigo, there were no significant differences between the patients with and the patients without postoperative vertigo. Besides morphological changes, a cochlear implantation also causes functional damage of vestibular parts of the labyrinth. Our study showed a significant worsening of the caloric response. However, this alteration did not lead to vertigo complaints in all patients. It is therefore presumed that additional damage to sensory or visual afferents and central vestibular compensatory mechanisms play a role.
Literature
9.
go back to reference Jongkees LB, Maas JP, Philipszoon AJ (1962) Clinical nystagmography. A detailed study of electro-nystagmography in 341 patients with vertigo. Pract Otorhinolaryngol (Basel) 24:65–93 Jongkees LB, Maas JP, Philipszoon AJ (1962) Clinical nystagmography. A detailed study of electro-nystagmography in 341 patients with vertigo. Pract Otorhinolaryngol (Basel) 24:65–93
12.
go back to reference Mulch G, Leonardy B, Petermann W (1978) Normal values of the caloric test. Laryngol Rhinol Otol (Stuttg) 57(6):528–540 Mulch G, Leonardy B, Petermann W (1978) Normal values of the caloric test. Laryngol Rhinol Otol (Stuttg) 57(6):528–540
13.
go back to reference O’Leary MJ, Fayad J, House WF, Linthicum FH Jr (1991) Electrode insertion trauma in cochlear implantation. Ann Otol Rhinol Laryngol 100:695–699PubMed O’Leary MJ, Fayad J, House WF, Linthicum FH Jr (1991) Electrode insertion trauma in cochlear implantation. Ann Otol Rhinol Laryngol 100:695–699PubMed
14.
go back to reference Mangham CA (1987) Effects of cochlear prostheses on vestibulo-ocular reflexes to rotation. Ann Otol Rhinol Laryngol Suppl 128:101–104 Mangham CA (1987) Effects of cochlear prostheses on vestibulo-ocular reflexes to rotation. Ann Otol Rhinol Laryngol Suppl 128:101–104
15.
go back to reference Cohen NL, Hoffman RA (1991) Complications of cochlear implant surgery in adults and children. Ann Otol Rhinol Laryngol 100:708–711PubMed Cohen NL, Hoffman RA (1991) Complications of cochlear implant surgery in adults and children. Ann Otol Rhinol Laryngol 100:708–711PubMed
17.
go back to reference Graham SS, Dickins JR (1995) Postimplantation Meniere’s syndrome with fluctuant electrical thresholds. Ann Otol Rhinol Laryngol Suppl 166:412–414PubMed Graham SS, Dickins JR (1995) Postimplantation Meniere’s syndrome with fluctuant electrical thresholds. Ann Otol Rhinol Laryngol Suppl 166:412–414PubMed
Metadata
Title
Effect of cochlear implantation on horizontal semicircular canal function
Authors
Eike Krause
Julia P. R. Louza
John-Martin Hempel
Juliane Wechtenbruch
Tobias Rader
Robert Gürkov
Publication date
01-06-2009
Publisher
Springer-Verlag
Published in
European Archives of Oto-Rhino-Laryngology / Issue 6/2009
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-008-0815-5

Other articles of this Issue 6/2009

European Archives of Oto-Rhino-Laryngology 6/2009 Go to the issue