Published in: Archives of Gynecology and Obstetrics 1/2019

01-07-2019 | Artificial Intelligence | Review

Use of artificial intelligence (AI) in the interpretation of intrapartum fetal heart rate (FHR) tracings: a systematic review and meta-analysis

Published in: Archives of Gynecology and Obstetrics | Issue 1/2019

Login to get access

Abstract

Objectives

To determine the degree of inter-rater reliability (IRR) between human and artificial intelligence (AI) interpretation of fetal heart rate tracings (FHR), and to determine whether AI-assisted electronic fetal monitoring interpretation improves neonatal outcomes amongst laboring women.

Data sources

We searched Medline, EMBASE, Google Scholar, Scopus, ISI Web of Science and Cochrane database search, as well as PubMed (www.​pubmed.​gov) and RCT registry (www.​clinicaltrials.​gov) until the end of October 2018 to conduct a systematic review and meta-analysis comparing visual and AI interpretation of EFM in labor. Similarly, we sought out all studies evaluating the IRR between AI and expert interpretation of EFM.

Tabulation, integration and results

Weighed mean Cohen’s Kappa was calculated to assess the global IRR. Risk of bias was assessed using the Cochrane Handbook for Systematic Reviews of Interventions. We used relative risks (RR) and a random effects (RE) model to calculate weighted estimates. Statistical homogeneity was checked by the χ2 test and I2 using Review Manager 5.3.5 (The Cochrane Collaboration, 2014.) We obtained 201 records, of which 9 met inclusion criteria. Three RCT’s were used to compare the neonatal outcomes and 6 cohort studies were used to establish the degree of IRR between both approaches of EFM evaluation. With regards to the neonatal outcomes, a total of 55,064 patients were included in the analysis. Relative to the use of clinical (visual) evaluation of the FHR, the use of AI did not change the incidence rates of neonatal acidosis, cord pH below < 7.20, 5-min APGAR scores < 7, mode of delivery, NICU admission, neonatal seizures, or perinatal death. With regards to the degrees of inter-rater reliability, a weighed mean Cohen’s Kappa of 0.49 [0.32–0.66] indicates moderate agreement between expert observers and computerized systems.

Conclusion

The use of AI and computer analysis for the interpretation of EFM during labor does not improve neonatal outcomes. Inter-rater reliability between experts and computer systems is moderate at best. Future studies should aim at further elucidating these findings.
Literature
1.
go back to reference Verghese A, Shah NH, Harrington RA (2018) What this computer needs is a physician: humanism and artificial intelligence. JAMA 319(1):19–20CrossRefPubMed Verghese A, Shah NH, Harrington RA (2018) What this computer needs is a physician: humanism and artificial intelligence. JAMA 319(1):19–20CrossRefPubMed
2.
3.
go back to reference Macones GA et al (2008) The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring: update on definitions, interpretation, and research guidelines. Obstet Gynecol 112(3):661–666CrossRefPubMed Macones GA et al (2008) The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring: update on definitions, interpretation, and research guidelines. Obstet Gynecol 112(3):661–666CrossRefPubMed
4.
go back to reference Jauniaux E, Prefumo F (2016) Fetal heart monitoring in labour: from pinard to artificial intelligence. BJOG 123(6):870CrossRefPubMed Jauniaux E, Prefumo F (2016) Fetal heart monitoring in labour: from pinard to artificial intelligence. BJOG 123(6):870CrossRefPubMed
5.
go back to reference Lear CA et al (2016) The myths and physiology surrounding intrapartum decelerations: the critical role of the peripheral chemoreflex. J Physiol 594(17):4711–4725CrossRefPubMedPubMedCentral Lear CA et al (2016) The myths and physiology surrounding intrapartum decelerations: the critical role of the peripheral chemoreflex. J Physiol 594(17):4711–4725CrossRefPubMedPubMedCentral
6.
go back to reference Liston R, Sawchuck D, Young D (2018) No. 197b-Fetal health surveillance: intrapartum consensus guideline. J Obstet Gynaecol Can 40(4):e298–e322CrossRefPubMed Liston R, Sawchuck D, Young D (2018) No. 197b-Fetal health surveillance: intrapartum consensus guideline. J Obstet Gynaecol Can 40(4):e298–e322CrossRefPubMed
7.
go back to reference Alfirevic Z et al (2017) Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. Cochrane Database Syst Rev 2:CD006066PubMed Alfirevic Z et al (2017) Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. Cochrane Database Syst Rev 2:CD006066PubMed
8.
go back to reference Group, I.C. (2017) Computerised interpretation of fetal heart rate during labour (INFANT): a randomised controlled trial. Lancet 389(10080):1719–1729CrossRef Group, I.C. (2017) Computerised interpretation of fetal heart rate during labour (INFANT): a randomised controlled trial. Lancet 389(10080):1719–1729CrossRef
9.
go back to reference Ignatov PN, Lutomski JE (2016) Quantitative cardiotocography to improve fetal assessment during labor: a preliminary randomized controlled trial. Eur J Obstet Gynecol Reprod Biol 205:91–97CrossRefPubMed Ignatov PN, Lutomski JE (2016) Quantitative cardiotocography to improve fetal assessment during labor: a preliminary randomized controlled trial. Eur J Obstet Gynecol Reprod Biol 205:91–97CrossRefPubMed
10.
go back to reference Nunes I et al (2017) Central fetal monitoring with and without computer analysis: a randomized controlled trial. Obstet Gynecol 129(1):83–90CrossRefPubMed Nunes I et al (2017) Central fetal monitoring with and without computer analysis: a randomized controlled trial. Obstet Gynecol 129(1):83–90CrossRefPubMed
11.
go back to reference Sun S (2011) Meta-analysis of Cohen’s kappa. Health Serv Outcomes Res Method 11(3–4):145–163CrossRef Sun S (2011) Meta-analysis of Cohen’s kappa. Health Serv Outcomes Res Method 11(3–4):145–163CrossRef
12.
go back to reference Jackson M et al (2011) Frequency of fetal heart rate categories and short-term neonatal outcome. Obstet Gynecol 118(4):803–808CrossRefPubMed Jackson M et al (2011) Frequency of fetal heart rate categories and short-term neonatal outcome. Obstet Gynecol 118(4):803–808CrossRefPubMed
14.
go back to reference Fairley S, Lawson H, Morris K (2000) Inter-observer agreement in cardiotocogram interpretation: how reliable is Ontario? J SOGC 22(5):366–373CrossRef Fairley S, Lawson H, Morris K (2000) Inter-observer agreement in cardiotocogram interpretation: how reliable is Ontario? J SOGC 22(5):366–373CrossRef
15.
go back to reference Donker DK, van Geijn HP, Hasman A (1993) Interobserver variation in the assessment of fetal heart rate recordings. Eur J Obstet Gynecol 52(1):21–28CrossRef Donker DK, van Geijn HP, Hasman A (1993) Interobserver variation in the assessment of fetal heart rate recordings. Eur J Obstet Gynecol 52(1):21–28CrossRef
16.
go back to reference Parer JT et al (2006) Fetal acidemia and electronic fetal heart rate patterns: is there evidence of an association? J Matern Fetal Neonatal Med 19(5):289–294CrossRefPubMed Parer JT et al (2006) Fetal acidemia and electronic fetal heart rate patterns: is there evidence of an association? J Matern Fetal Neonatal Med 19(5):289–294CrossRefPubMed
17.
go back to reference Akselrod S et al (1981) Power spectrum analysis of heart rate fluctuation: a quantitative probe of beat-to-beat cardiovascular control. Science 213(4504):220–222CrossRefPubMed Akselrod S et al (1981) Power spectrum analysis of heart rate fluctuation: a quantitative probe of beat-to-beat cardiovascular control. Science 213(4504):220–222CrossRefPubMed
18.
go back to reference Parer JT, Hamilton EF (2010) Comparison of 5 experts and computer analysis in rule-based fetal heart rate interpretation. Am J Obstet Gynecol 203(5):451 (e1-7) CrossRefPubMed Parer JT, Hamilton EF (2010) Comparison of 5 experts and computer analysis in rule-based fetal heart rate interpretation. Am J Obstet Gynecol 203(5):451 (e1-7) CrossRefPubMed
19.
go back to reference Devoe L et al (2000) A comparison of visual analyses of intrapartum fetal heart rate tracings according to the new national institute of child health and human development guidelines with computer analyses by an automated fetal heart rate monitoring system. Am J Obstet Gynecol 183(2):361–366CrossRefPubMed Devoe L et al (2000) A comparison of visual analyses of intrapartum fetal heart rate tracings according to the new national institute of child health and human development guidelines with computer analyses by an automated fetal heart rate monitoring system. Am J Obstet Gynecol 183(2):361–366CrossRefPubMed
20.
go back to reference Bracero LA, Roshanfekr D, Byrne DW (2000) Analysis of antepartum fetal heart rate tracing by physician and computer. J Maternal Fetal Med 9(3):181–185 Bracero LA, Roshanfekr D, Byrne DW (2000) Analysis of antepartum fetal heart rate tracing by physician and computer. J Maternal Fetal Med 9(3):181–185
21.
go back to reference Costa MA et al (2010) Comparison of a computer system evaluation of intrapartum cardiotocographic events and a consensus of clinicians. J Perinat Med 38(2):191–195CrossRefPubMed Costa MA et al (2010) Comparison of a computer system evaluation of intrapartum cardiotocographic events and a consensus of clinicians. J Perinat Med 38(2):191–195CrossRefPubMed
22.
go back to reference Krupa N et al (2011) Antepartum fetal heart rate feature extraction and classification using empirical mode decomposition and support vector machine. Biomed Eng Online 10:6CrossRefPubMedPubMedCentral Krupa N et al (2011) Antepartum fetal heart rate feature extraction and classification using empirical mode decomposition and support vector machine. Biomed Eng Online 10:6CrossRefPubMedPubMedCentral
23.
Metadata
Title
Use of artificial intelligence (AI) in the interpretation of intrapartum fetal heart rate (FHR) tracings: a systematic review and meta-analysis
Publication date
01-07-2019
Published in
Archives of Gynecology and Obstetrics / Issue 1/2019
Print ISSN: 0932-0067
Electronic ISSN: 1432-0711
DOI
https://doi.org/10.1007/s00404-019-05151-7

Other articles of this Issue 1/2019

Archives of Gynecology and Obstetrics 1/2019 Go to the issue