Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 8/2023

Open Access 17-01-2023 | Orthopaedic Surgery

Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty

Authors: Felix Riechelmann, H. Lettner, R. Mayr, R. Tandogan, D. Dammerer, M. Liebensteiner

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 8/2023

Login to get access

Abstract

Purpose

To analyze the match between preoperatively determined implant size (2D templating) and intraoperatively used implant size in total knee arthroplasty (TKA). Also examined were the factors that might influence templating accuracy (gender, surgeon experience, obesity, etc.).

Materials and methods

The study was retrospective and conducted in a specialized ENDOCERT arthroplasty center. Digital templating was done with the MediCAD software. If the planned and implanted TKA components (both femur and tibia) were the same size, the match was classified “exact.” A deviation of ± one size (at the femur or tibia or both) was classified “accurate.” A deviation of ± two or more sizes (at the femur or tibia or both) was classified “inaccurate.” Obesity, gender, implant type and surgeon experience were investigated for potential influence on templating accuracy. Chi-square tests and Cohen’s weighted kappa test were used for statistical analysis.

Results

A total of 482 cases [33.6% male, 66.4% female, age 69 ± 11, body mass index (BMI) 30.3 ± 5.8] were included. When the femur and tibia were taken together, exact size match was observed in 34% (95% CI 29.9–38.3%) of cases, accurate size match in 57.5% (95% CI 53–61.8%) and inaccurate size match in 8.5% (95% CI 6.3–11.2%). Inaccurate size match prolonged operative time (p = 0.028). Regarding the factors potentially influencing templating accuracy, only gender had a significant influence, with templating being more accurate in men (p = 0.004). BMI had no influence on accuracy (p = 0.87). No effect on accuracy was observed for implant type and surgeon experience.

Conclusions

The accuracy of 2D size templating in TKA is low, even in a specialized ENDOCERT arthroplasty center. The study findings challenge the usefulness of preoperative 2D size templating and highlight the importance of more reliable templating methods.

Level of evidence

Level III (retrospective observational study).
Literature
3.
go back to reference Levine B, Fabi D, Deirmengian C (2010) Digital templating in primary total hip and knee arthroplasty. Orthopedics 33(11):1–5CrossRef Levine B, Fabi D, Deirmengian C (2010) Digital templating in primary total hip and knee arthroplasty. Orthopedics 33(11):1–5CrossRef
4.
go back to reference Specht LM, Levitz S, Iorio R, Healy WL, Tilzey JF (2007) A comparison of acetate and digital templating for total knee arthroplasty. Clin Orthop Relat Res (1976–2007) 464:179–183CrossRef Specht LM, Levitz S, Iorio R, Healy WL, Tilzey JF (2007) A comparison of acetate and digital templating for total knee arthroplasty. Clin Orthop Relat Res (1976–2007) 464:179–183CrossRef
5.
go back to reference Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL (2009) A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe? J Arthroplasty 24(2):175–179CrossRefPubMed Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL (2009) A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe? J Arthroplasty 24(2):175–179CrossRefPubMed
6.
go back to reference Ettinger M, Claassen L, Paes P, Calliess T (2016) 2D versus 3D templating in total knee arthroplasty. Knee 23(1):149–151CrossRefPubMed Ettinger M, Claassen L, Paes P, Calliess T (2016) 2D versus 3D templating in total knee arthroplasty. Knee 23(1):149–151CrossRefPubMed
12.
go back to reference Kniesel B, Konstantinidis L, Hirschmüller A, Südkamp N, Helwig P (2014) Digital templating in total knee and hip replacement: an analysis of planning accuracy. Int Orthop 38(4):733–739CrossRefPubMed Kniesel B, Konstantinidis L, Hirschmüller A, Südkamp N, Helwig P (2014) Digital templating in total knee and hip replacement: an analysis of planning accuracy. Int Orthop 38(4):733–739CrossRefPubMed
13.
go back to reference Miller AG, Purtill JJ (2012) Accuracy of digital templating in total knee arthroplasty. Am J Orthop (Belle Mead NJ) 41(11):510–512PubMed Miller AG, Purtill JJ (2012) Accuracy of digital templating in total knee arthroplasty. Am J Orthop (Belle Mead NJ) 41(11):510–512PubMed
14.
go back to reference Hernandez-Vaquero D, Abat F, Sarasquete J, Monllau JC (2013) Reliability of preoperative measurement with standardized templating in total knee arthroplasty. World J Orthop 4(4):287CrossRefPubMedPubMedCentral Hernandez-Vaquero D, Abat F, Sarasquete J, Monllau JC (2013) Reliability of preoperative measurement with standardized templating in total knee arthroplasty. World J Orthop 4(4):287CrossRefPubMedPubMedCentral
15.
go back to reference Wallace SJ, Murphy MP, Schiffman CJ, Hopkinson WJ, Brown NM (2020) Demographic data is more predictive of component size than digital radiographic templating in total knee arthroplasty. Knee Surg Relat Res 32(1):1–7CrossRef Wallace SJ, Murphy MP, Schiffman CJ, Hopkinson WJ, Brown NM (2020) Demographic data is more predictive of component size than digital radiographic templating in total knee arthroplasty. Knee Surg Relat Res 32(1):1–7CrossRef
17.
go back to reference León-Muñoz VJ, Lisón-Almagro AJ, López-López M (2020) Planning on CT-based 3D virtual models can accurately predict the component size for total knee arthroplasty. J Knee Surg 33(11):1128–1131CrossRefPubMed León-Muñoz VJ, Lisón-Almagro AJ, López-López M (2020) Planning on CT-based 3D virtual models can accurately predict the component size for total knee arthroplasty. J Knee Surg 33(11):1128–1131CrossRefPubMed
Metadata
Title
Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty
Authors
Felix Riechelmann
H. Lettner
R. Mayr
R. Tandogan
D. Dammerer
M. Liebensteiner
Publication date
17-01-2023
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 8/2023
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-023-04772-7

Other articles of this Issue 8/2023

Archives of Orthopaedic and Trauma Surgery 8/2023 Go to the issue