30-08-2021 | Arthroscopy and Sports Medicine

Novel press-fit technique of patellar bone plug in anterior cruciate ligament reconstruction is comparable to interference screw fixation

Authors: Janosch Häberli, Maximilian Heilgemeir, Sebastian Valet, Ameet Aiyangar, Tom Overes, Philipp Henle, Stefan Eggli

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 8/2022

Login to get access

Abstract

Purpose

Conventional press-fit technique for anterior cruciate ligament reconstruction (ACLR) is performed with extraction drilling of the femoral bone tunnel and manual shaping of the patellar bone plug. However, the disadvantages of this technique include variation in bone plug size and, thus, the strength of the press-fit fixation, bone loss with debris distribution within the knee joint, potential heat necrosis, and metal wear debris due to abrasion of the guide wire. To overcome these disadvantages, a novel technique involving punching of the femoral bone tunnel and standardized compression of the bone plug was introduced. In this study, the fixation strength and apparent stiffness were tested and compared to that of the gold-standard interference screw fixation technique in three flexion angle configurations (0°/45°/90°) in a porcine model. We hypothesized that the newly developed standardized press fit fixation would not be inferior to the gold standard method.

Methods

Sixty skeletally mature porcine knees (30 pairs) were used. Full-thickness central third patellar tendon strips were harvested, including a patellar bone cylinder of 9.5 mm in diameter. The specimens were randomly assigned to 10 pairs per loading angle (0°, 45°, 90°). One side of each pair was prepared with the press-fit technique, and the contra-lateral side was prepared with interference screw fixation. Equivalent numbers of left- and right-sided samples were used for both fixation systems. A three-way multifactor ANOVA was carried out to check for the influence of (a) fixation type, (b) flexion angle, and (c) side of the bone pair.

Results

The primary fixation strength of femoral press-fit graft fixation with punched tunnels and standardized bone plug compression did not differ significantly from that of interference screw fixation (p = 0.51), which had mean loads to failure of 422.4 ± 134.6 N and 445.4 ± 135.8 N, respectively. The flexion angle had a significant influence on the maximal load to failure (p = 0.01). Load values were highest in 45° flexion for both fixations. The anatomical side R/L was not a statistically significant factor (p = 0.79).

Conclusion

The primary fixation strength of femoral press-fit graft fixation with punched femoral tunnels and standardized bone plug compression is equivalent to that of interference screw fixation in a porcine model. Therefore, the procedure represents an effective method for ACL reconstruction with patellar or quadriceps tendon autografts including a patellar bone plug.
Literature
2.
7.
go back to reference Chiang ER, Chen KH, Chih-Chang Lin A et al (2019) Comparison of tunnel enlargement and clinical outcome between bioabsorbable interference screws and cortical button-post fixation in arthroscopic double-bundle anterior cruciate ligament reconstruction: a prospective, randomized study with a minimum follow up of 2 years. Arthrosc - J Arthrosc Relat Surg 35:544–551. https://doi.org/10.1016/j.arthro.2018.08.039CrossRef Chiang ER, Chen KH, Chih-Chang Lin A et al (2019) Comparison of tunnel enlargement and clinical outcome between bioabsorbable interference screws and cortical button-post fixation in arthroscopic double-bundle anterior cruciate ligament reconstruction: a prospective, randomized study with a minimum follow up of 2 years. Arthrosc - J Arthrosc Relat Surg 35:544–551. https://​doi.​org/​10.​1016/​j.​arthro.​2018.​08.​039CrossRef
16.
go back to reference Ugutmen E, Ozkan K, Güven M et al (2007) Early tunnel enlargement after arthroscopic ACL reconstructions. Acta Orthop Belg 73:625–629PubMed Ugutmen E, Ozkan K, Güven M et al (2007) Early tunnel enlargement after arthroscopic ACL reconstructions. Acta Orthop Belg 73:625–629PubMed
22.
go back to reference Lee MC, Jo H, Bae TS et al (2003) Analysis of initial fixation strength of press-fit fixation technique in anterior cruciate ligament reconstruction: a comparative study with titanium and bioabsorbable interference screw using porcine lower limb. Knee Surg, Sport Traumatol Arthrosc 11:91–98. https://doi.org/10.1007/s00167-003-0351-1CrossRef Lee MC, Jo H, Bae TS et al (2003) Analysis of initial fixation strength of press-fit fixation technique in anterior cruciate ligament reconstruction: a comparative study with titanium and bioabsorbable interference screw using porcine lower limb. Knee Surg, Sport Traumatol Arthrosc 11:91–98. https://​doi.​org/​10.​1007/​s00167-003-0351-1CrossRef
30.
Metadata
Title
Novel press-fit technique of patellar bone plug in anterior cruciate ligament reconstruction is comparable to interference screw fixation
Authors
Janosch Häberli
Maximilian Heilgemeir
Sebastian Valet
Ameet Aiyangar
Tom Overes
Philipp Henle
Stefan Eggli
Publication date
30-08-2021
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 8/2022
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-021-04137-y

Other articles of this Issue 8/2022

Archives of Orthopaedic and Trauma Surgery 8/2022 Go to the issue