Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 1/2020

01-01-2020 | Periprosthetic Fracture | Knee Arthroplasty

Early complications and causes of revision after rotating-hinge TKA

Authors: L. Rouquette, C. Batailler, B. Muller, P. Neyret, E. Servien, S. Lustig

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 1/2020

Login to get access

Abstract

Introduction

The use of rotating-hinge total knee arthroplasties (TKA), despite several developments in prosthetic design, remains controversial. Results as well as indications of these devices are still discussed in primary intention and for young patients. The aim was to analyze early complications and survival rate of rotating-hinge TKA in primary intention and for revisions.

Methods

A retrospective study included all the patients operated for primary or revision TKA procedure using a rotating-hinge TKA between 2015 and 2018. Clinical and radiological data were collected before surgery and then at a minimum follow-up of 1 year. The primary endpoint was the aseptic revision-free survival rate. Secondary endpoints were the overall survival rate, IKS scores, range of motion and patellar complications.

Results

Forty patients were included at an average follow-up of 18 months. Primary implantation was performed for 12 patients (30%), and revision for 28 cases (70%). At a mean follow-up of 18 months, only one implant was removed for a septic cause. The cumulative survival rate at 24 months was 95%. At final review, eight knees (20%) had been revised, five (12.5%) due to infection, two (5%) because of extensor mechanism failure, two (5%) for global stiffness. The objective and subjective IKS were significantly higher postoperatively in both primary and revision groups (p < 0.0001). Patellar height was significantly smaller after revision (p = 0.04), while ROM significantly improved in this group (p = 0.02). At final endpoint, one implant was removed for a septic cause.

Conclusion

This rotating-hinge TKA provides satisfying clinical and functional outcomes in primary intentions and in revision cases. There was no implant-associated complication. The complication rate remains high for revision surgery cases, mostly due to previous joint infections and poor soft tissue quality causing extensor mechanism failure. A longer-term study should be conducted to confirm this trend.
Literature
2.
go back to reference Parratte S, Pagnano MW (2008) Instability after total knee arthroplasty. Instr Course Lect 57:295–304PubMed Parratte S, Pagnano MW (2008) Instability after total knee arthroplasty. Instr Course Lect 57:295–304PubMed
6.
go back to reference Barrack RL (2001) Evolution of the rotating hinge for complex total knee arthroplasty. Clin Orthop Relat Res 392(392):292–299CrossRef Barrack RL (2001) Evolution of the rotating hinge for complex total knee arthroplasty. Clin Orthop Relat Res 392(392):292–299CrossRef
7.
go back to reference Jones EC, Insall JN, Inglis AE, Ranawat CS (1979) GUEPAR knee arthroplasty results and late complications. Clin Orthop Relat Res 140:145–152 Jones EC, Insall JN, Inglis AE, Ranawat CS (1979) GUEPAR knee arthroplasty results and late complications. Clin Orthop Relat Res 140:145–152
8.
go back to reference Barrack RL (2002) Rise of the rotating hinge in revision total knee arthroplasty. Orthopedics 25(10):1020–1058PubMed Barrack RL (2002) Rise of the rotating hinge in revision total knee arthroplasty. Orthopedics 25(10):1020–1058PubMed
9.
go back to reference Kester MA, Cook SD, Harding AF, Rodriguez RP, Pipkin CS (1988) An evaluation of the mechanical failure modalities of a rotating hinge knee prosthesis. Clin Orthop Relat Res 228:156–163 Kester MA, Cook SD, Harding AF, Rodriguez RP, Pipkin CS (1988) An evaluation of the mechanical failure modalities of a rotating hinge knee prosthesis. Clin Orthop Relat Res 228:156–163
10.
go back to reference Draganich LF, Whitehurst JB, Chou LS, Piotrowski GA, Pottenger LA, Finn HA (1999) The effects of the rotating-hinge total knee replacement on gait and stair stepping. J Arthroplasty 14(6):743–755CrossRef Draganich LF, Whitehurst JB, Chou LS, Piotrowski GA, Pottenger LA, Finn HA (1999) The effects of the rotating-hinge total knee replacement on gait and stair stepping. J Arthroplasty 14(6):743–755CrossRef
13.
go back to reference Petrou G, Petrou H, Tilkeridis C, Stavrakis T, Kapetsis T, Kremmidas N et al (2004) Medium-term results with a primary cemented rotating-hinge total knee replacement. A 7- to 15-year follow-up. J Bone Joint Surg Br 86(6):813–817CrossRef Petrou G, Petrou H, Tilkeridis C, Stavrakis T, Kapetsis T, Kremmidas N et al (2004) Medium-term results with a primary cemented rotating-hinge total knee replacement. A 7- to 15-year follow-up. J Bone Joint Surg Br 86(6):813–817CrossRef
21.
go back to reference Springer BD, Hanssen AD, Sim FH, Lewallen DG (2001) The kinematic rotating hinge prosthesis for complex knee arthroplasty. Clin Orthop Relat Res 392(392):283–291CrossRef Springer BD, Hanssen AD, Sim FH, Lewallen DG (2001) The kinematic rotating hinge prosthesis for complex knee arthroplasty. Clin Orthop Relat Res 392(392):283–291CrossRef
22.
go back to reference Westrich GH, Mollano AV, Sculco TP, Buly RL, Laskin RS, Windsor R (2000) Rotating hinge total knee arthroplasty in severly affected knees. Clin Orthop Relat Res 379(379):195–208CrossRef Westrich GH, Mollano AV, Sculco TP, Buly RL, Laskin RS, Windsor R (2000) Rotating hinge total knee arthroplasty in severly affected knees. Clin Orthop Relat Res 379(379):195–208CrossRef
Metadata
Title
Early complications and causes of revision after rotating-hinge TKA
Authors
L. Rouquette
C. Batailler
B. Muller
P. Neyret
E. Servien
S. Lustig
Publication date
01-01-2020
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 1/2020
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-019-03290-9

Other articles of this Issue 1/2020