Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 9/2019

01-09-2019 | Magnetic Resonance Imaging | Arthroscopy and Sports Medicine

Prevalence, development, and factors associated with cyst formation after meniscal repair with the all-inside suture device

Authors: Shozaburo Terai, Yusuke Hashimoto, Shinya Yamasaki, Shinji Takahashi, Nagakazu Shimada, Hiroaki Nakamura

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 9/2019

Login to get access

Abstract

Purpose

To investigate the prevalence of cyst formation after using all-inside meniscal repair device and analysed the risk factors associated with it.

Methods

Between August 2008 and September 2013, 51 menisci of 46 patients were included in the study, 46 menisci of which had concomitant anterior cruciate ligament (ACL) ruptures and had an ACL reconstruction. Magnetic resonance imaging (MRI) of the knee was performed at 3, 6, 12 and 24 months after meniscal surgery. The MRIs were assessed to detect the development of cysts encasing the suture anchors and to evaluate meniscal healing. Statistical analysis was performed using multiple regression analysis.

Results

Out of the 51 menisci examined, MRI revealed cysts in 15 menisci. Cysts were detected in 3 menisci at 6 months, in 9 menisci at 12 months, and in 3 menisci at 24 months after surgery. Only 3 patients (6.5%) were symptomatic, and cystectomy was performed in 2 of these patients and arthroscopic debridement in the other. Compared with using both the suture device and an inside-out suture repair, using the suture device alone was more likely to be associated with cyst development [odds ratio (OR), 12.04]. The medial meniscus was also significantly more likely to develop a cyst compared with the lateral meniscus (OR, 12.48). There was an increased outcome for the number of device use (P = 0.033). Though it was not statistically significant, the patients with anterior knee laxity (side-to-side difference > 3 mm using a knee arthrometer) were more likely to develop cysts than those without anterior knee laxity (P = 0.06). There were no significant differences between the remaining variables.

Conclusions

The prevalence of cyst formation around the suture implant was 29%, but most cases were not symptomatic. Significant risk factors for cyst formation included the use of a suture device alone, and a location in the medial meniscus.

Level of evidence

III.
Literature
3.
go back to reference Henning CE, Clark JR, Lynch MA et al (1988) Arthroscopic meniscus repair with a posterior incision. Instr Course Lect 37:209–221PubMed Henning CE, Clark JR, Lynch MA et al (1988) Arthroscopic meniscus repair with a posterior incision. Instr Course Lect 37:209–221PubMed
9.
go back to reference Morgan CD (1991) The ‘All-Inside’ meniscus repair. J Arthrosc Relat Surg 7(1):120–125CrossRef Morgan CD (1991) The ‘All-Inside’ meniscus repair. J Arthrosc Relat Surg 7(1):120–125CrossRef
14.
go back to reference Cohen SB, Boyd L, Miller MD (2007) Vascular risk associated with meniscal repair using Rapidloc versus FasT-Fix: comparison of two all-inside meniscal devices. J Knee Surg 20:235–240CrossRefPubMed Cohen SB, Boyd L, Miller MD (2007) Vascular risk associated with meniscal repair using Rapidloc versus FasT-Fix: comparison of two all-inside meniscal devices. J Knee Surg 20:235–240CrossRefPubMed
17.
go back to reference Albrecht-Olsen P, Kristensen G, Törmälä P (1993) Meniscus bucket-handle fixation with an absorbable Biofix tack: development of a new technique. Knee Surg Sports Traumatol Arthrosc 1:104–106CrossRefPubMed Albrecht-Olsen P, Kristensen G, Törmälä P (1993) Meniscus bucket-handle fixation with an absorbable Biofix tack: development of a new technique. Knee Surg Sports Traumatol Arthrosc 1:104–106CrossRefPubMed
18.
go back to reference Barber FA (2000) Articular cartilage damage, peripheral migration, and device failure as meniscal arrow complications: case report. Am J Knee Surg 13:234–236PubMed Barber FA (2000) Articular cartilage damage, peripheral migration, and device failure as meniscal arrow complications: case report. Am J Knee Surg 13:234–236PubMed
34.
go back to reference Kang HJ, Chun CH, Kim SH, Kim KM (2012) A ganglion cyst generated by non-absorbable meniscal repair suture material. Orthop Traumatol Surg Res 98:608–612CrossRefPubMed Kang HJ, Chun CH, Kim SH, Kim KM (2012) A ganglion cyst generated by non-absorbable meniscal repair suture material. Orthop Traumatol Surg Res 98:608–612CrossRefPubMed
36.
go back to reference Lombardo S, Eberly V (2016) Meniscal cyst formation after All-Inside meniscal repair. Am J Sports Med 27(5):666–667CrossRef Lombardo S, Eberly V (2016) Meniscal cyst formation after All-Inside meniscal repair. Am J Sports Med 27(5):666–667CrossRef
Metadata
Title
Prevalence, development, and factors associated with cyst formation after meniscal repair with the all-inside suture device
Authors
Shozaburo Terai
Yusuke Hashimoto
Shinya Yamasaki
Shinji Takahashi
Nagakazu Shimada
Hiroaki Nakamura
Publication date
01-09-2019
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 9/2019
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-019-03176-w

Other articles of this Issue 9/2019

Archives of Orthopaedic and Trauma Surgery 9/2019 Go to the issue