Published in: Archives of Orthopaedic and Trauma Surgery 5/2018

01-05-2018 | Knee Arthroplasty

Normalized gait analysis parameters are closely related to patient-reported outcome measures after total knee arthroplasty

Authors: Julia Kirschberg, Szymon Goralski, Frank Layher, Klaus Sander, Georg Matziolis

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 5/2018

Login to get access

Abstract

Up till now, only a weak connection could be shown between patient-related outcome measures (PROMs) and measurements obtained by gait analysis (e.g. speed, step length, cadence, ground reaction force, joint moments and ranges of motion) after total knee arthroplasty (TKA). This may result from the methodical problem that regression analyses are performed using data that are not normalized against a healthy population. It does appear reasonable to assume that patients presenting a physiological gait pattern are content with their joint. The more the gait parameters differ from a normal gait pattern the worse the clinical outcome measured by PROMs should be expected to be. In this retrospective study, 40 patients were enrolled who had received a gait analysis after TKA, and whose PROMs had been evaluated. A gender- and age-matched control group was formed out of a group of test persons who had already undergone gait analysis. Gait analysis was undertaken using the motion analysis system 3D Vicon with ten infrared cameras and three strength measuring force plates. The physiological gait analysis parameters were deduced from arithmetic mean values taken from all control patients. The deviances of the operated patients’ gait analysis parameters from the arithmetic mean values were squared. From these values, the Pearson correlation coefficients for different PROMs were then calculated, and regression analyses were performed to elucidate the correlation between the different PROMs and gait parameters. In the regression analysis, the normalized cadence, relative gait speed of the non-operated side, and range of the relative knee moment of the operated side could be identified as factors which influence the Forgotten Joint Score (FJS-12). The explanation model showed an increase of the FJS-12 with minimisation of these normalized values corresponding to an approximation of the gait pattern seen in the healthy control group. The connection was strong, having a correlation coefficient of 0.708. A physiological gait pattern after TKA results in better PROMs, especially the FJS-12, than a non-physiological gait pattern does.
Literature
17.
go back to reference Saari T, Tranberg R, Zügner R et al (2005) Changed gait pattern in patients with total knee arthroplasty but minimal influence of tibial insert design: gait analysis during level walking in 39 TKR patients and 18 healthy controls. Acta Orthop 76:253–260CrossRefPubMed Saari T, Tranberg R, Zügner R et al (2005) Changed gait pattern in patients with total knee arthroplasty but minimal influence of tibial insert design: gait analysis during level walking in 39 TKR patients and 18 healthy controls. Acta Orthop 76:253–260CrossRefPubMed
33.
go back to reference Hajduk G, Nowak K, Sobota G et al (2016) Kinematic gait parameters changes in patients after total knee arthroplasty. Comparison between cruciate-retaining and posterior-substituting design. Acta Bioeng Biomech 18:137–142PubMed Hajduk G, Nowak K, Sobota G et al (2016) Kinematic gait parameters changes in patients after total knee arthroplasty. Comparison between cruciate-retaining and posterior-substituting design. Acta Bioeng Biomech 18:137–142PubMed
34.
go back to reference Otsuki T, Nawata K, Okuno M (1999) Quantitative evaluation of gait pattern in patients with osteoarthrosis of the knee before and after total knee arthroplasty. Gait analysis using a pressure measuring system. J Orthop Sci 4:99–105CrossRefPubMed Otsuki T, Nawata K, Okuno M (1999) Quantitative evaluation of gait pattern in patients with osteoarthrosis of the knee before and after total knee arthroplasty. Gait analysis using a pressure measuring system. J Orthop Sci 4:99–105CrossRefPubMed
Metadata
Title
Normalized gait analysis parameters are closely related to patient-reported outcome measures after total knee arthroplasty
Authors
Julia Kirschberg
Szymon Goralski
Frank Layher
Klaus Sander
Georg Matziolis
Publication date
01-05-2018
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 5/2018
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-018-2891-3

Other articles of this Issue 5/2018

Archives of Orthopaedic and Trauma Surgery 5/2018 Go to the issue