Abstract

Background

Acetabular fractures are amongst the most challenging fractures to treat because of complex anatomy. Open reduction and internal fixation remains the standard treatment for displaced acetabular fractures to achieve anatomical reduction as in any other intra-articular fracture. Patient-specific pre-contoured reconstruction plate template made by a pre-operative virtual surgical planning can be useful to respect patient’s morphology, reduce surgical invasiveness and simplify the surgical procedure. Proper evaluation and surgical planning is necessary to achieve these goals. The goal of this study was to evaluate the outcomes of using virtual surgical planning and virtually pre-contoured plate template in comparison with the conventional method of intra-operative contouring of reconstruction plate for acetabular fracture fixation.

Methods

Twenty-five patients were categorized into group A and B by computerized randomization. In group A (12 patients), CT-based virtual surgical planning was done using Mimics and 3-Matic software to form virtually pre-contoured plates, which were 3D printed to act as templates over which 3.5 mm reconstruction plates were manually contoured pre-operatively and used for fixation. In group B (13 patient), conventional method of intra-operative contouring to adapt the plate to the fracture region was followed. Blood loss, surgical time, reduction on X-rays and post-operative computed tomography were compared between two groups.

Results

Duration of surgery and total blood loss were found to be less while reduction was found to satisfactory/anatomical in higher percentage of Group A than Group B patients.

Conclusions

Virtual surgical planning, patient-specific virtually pre-contoured plate template and 3D printing technology improve the outcomes of acetabular fracture surgery by reducing duration and invasiveness of surgery and improving the quality of reduction. However, studies with larger sample size are required to further validate it.
Literature
1.
go back to reference Letournel E (1980) Acetabulum fractures: classification and management. Clin Orthop 151:81–106 Letournel E (1980) Acetabulum fractures: classification and management. Clin Orthop 151:81–106
2.
go back to reference Matta J, Anderson L, Epstein H, Hendricks P (1986) Fractures of the acetabulum: a retrospective analysis. Clin Orthop 205:230–240 Matta J, Anderson L, Epstein H, Hendricks P (1986) Fractures of the acetabulum: a retrospective analysis. Clin Orthop 205:230–240
3.
go back to reference Matta JM, Mehne DJK, Roffi R (1986) Fractures of the acetabulum: early results of a prospective study. Clin Orthop 205:241–250 Matta JM, Mehne DJK, Roffi R (1986) Fractures of the acetabulum: early results of a prospective study. Clin Orthop 205:241–250
4.
go back to reference Rommens PM (2004) The Kocher–Langenbeck approach for the treatment of acetabular fractures. Eur J Trauma 30:265–273CrossRef Rommens PM (2004) The Kocher–Langenbeck approach for the treatment of acetabular fractures. Eur J Trauma 30:265–273CrossRef
5.
go back to reference Letournel E, Judet R (1993) Fractures of the acetabulum, 2nd edn. Springer, New YorkCrossRef Letournel E, Judet R (1993) Fractures of the acetabulum, 2nd edn. Springer, New YorkCrossRef
6.
go back to reference De Ridder VA, de Lange S, Popta JV (1999) Anatomical variations of the lateral femoral cutaneous nerve and the consequences for surgery. J Orthop Trauma 13:207–211CrossRefPubMed De Ridder VA, de Lange S, Popta JV (1999) Anatomical variations of the lateral femoral cutaneous nerve and the consequences for surgery. J Orthop Trauma 13:207–211CrossRefPubMed
7.
go back to reference Tile M, helfet D, Kellam J (2003) Fractures of pelvis and acetabulum. Lippincott Williams and Wilkins, Philadelphia Tile M, helfet D, Kellam J (2003) Fractures of pelvis and acetabulum. Lippincott Williams and Wilkins, Philadelphia
8.
go back to reference Baumgaertner MR (1999) Fractures of the posterior wall of the acetabulum. J Am Acad Orthop Surg 7:54–65CrossRefPubMed Baumgaertner MR (1999) Fractures of the posterior wall of the acetabulum. J Am Acad Orthop Surg 7:54–65CrossRefPubMed
9.
go back to reference Browner BD, Helfet DL (1991) Internal fixation of a fractured acetabulum. Strateg Orthop Surg 10:1–16 Browner BD, Helfet DL (1991) Internal fixation of a fractured acetabulum. Strateg Orthop Surg 10:1–16
10.
go back to reference Bagaria V, Deshpande S, Rasalkar DD, Kuthe A, Paunipagar BK (2011) Use of rapid prototyping and three-dimensional reconstruction modeling in the management of complex fractures. Eur J Radiol 80(3):814–820 (Elsevier Ireland Ltd; Cited 24 Sept 2013) CrossRefPubMed Bagaria V, Deshpande S, Rasalkar DD, Kuthe A, Paunipagar BK (2011) Use of rapid prototyping and three-dimensional reconstruction modeling in the management of complex fractures. Eur J Radiol 80(3):814–820 (Elsevier Ireland Ltd; Cited 24 Sept 2013) CrossRefPubMed
11.
go back to reference Matta JM, Merritt PO (1988) Displaced acetabular fractures. Clin Orthop 230:83–97 Matta JM, Merritt PO (1988) Displaced acetabular fractures. Clin Orthop 230:83–97
12.
go back to reference Tornetta P 3rd (2001) Displaced acetabular fractures: indications for operative and nonoperative management. J Am Acad Orthop Surg 9(1):18–28CrossRefPubMed Tornetta P 3rd (2001) Displaced acetabular fractures: indications for operative and nonoperative management. J Am Acad Orthop Surg 9(1):18–28CrossRefPubMed
13.
go back to reference Rommens PM, Hessmann MH (1999) Acetabulum fractures. Unfallchirurg 102:589–590 Rommens PM, Hessmann MH (1999) Acetabulum fractures. Unfallchirurg 102:589–590
14.
go back to reference Zeng C, Xing W, Wu Z, Huang H, Huang W (2016) A combination of three-dimensional printing and computer-assisted virtual surgical procedure for preoperative planning of acetabular fracture reduction. Injury 47:2223–2227CrossRef Zeng C, Xing W, Wu Z, Huang H, Huang W (2016) A combination of three-dimensional printing and computer-assisted virtual surgical procedure for preoperative planning of acetabular fracture reduction. Injury 47:2223–2227CrossRef
15.
go back to reference Winder J, Bibb R (2005) Medical rapid prototyping technologies: state of the art and current limitations for application in oral and maxillofacial surgery. J Oral Maxillofac Surg 63:1006–1015CrossRefPubMed Winder J, Bibb R (2005) Medical rapid prototyping technologies: state of the art and current limitations for application in oral and maxillofacial surgery. J Oral Maxillofac Surg 63:1006–1015CrossRefPubMed
16.
go back to reference Cimerman M, Kristan A (2007) Preoperative planning in pelvic and acetabular surgery: the value of advanced computerised planning modules. Injury 38:442–449CrossRefPubMed Cimerman M, Kristan A (2007) Preoperative planning in pelvic and acetabular surgery: the value of advanced computerised planning modules. Injury 38:442–449CrossRefPubMed
17.
go back to reference Citak M, Gardner MJ, Kendoff D, Tarte S, Krettek C, Nolte LP, Hufner T (2008) Virtual 3D planning of acetabular fracture reduction. J Orthop Res 26:547–552CrossRefPubMed Citak M, Gardner MJ, Kendoff D, Tarte S, Krettek C, Nolte LP, Hufner T (2008) Virtual 3D planning of acetabular fracture reduction. J Orthop Res 26:547–552CrossRefPubMed
18.
go back to reference Fornaro J, Keel M, Harders M, Marincek B, Szekely G, Frauenfelder T (2010) An interactive surgical planning tool for acetabular fractures: initial results. J Orthop Surg Res 5:50CrossRefPubMedPubMedCentral Fornaro J, Keel M, Harders M, Marincek B, Szekely G, Frauenfelder T (2010) An interactive surgical planning tool for acetabular fractures: initial results. J Orthop Surg Res 5:50CrossRefPubMedPubMedCentral
19.
go back to reference Shen F, Chen B, Guo Q, Qi Y, Shen Y (2013) Augmented reality patient-specific reconstruction plate design for pelvic and acetabular fracture surgery. Int J Comput Assist Radiol Surg 8(2):169–179CrossRefPubMed Shen F, Chen B, Guo Q, Qi Y, Shen Y (2013) Augmented reality patient-specific reconstruction plate design for pelvic and acetabular fracture surgery. Int J Comput Assist Radiol Surg 8(2):169–179CrossRefPubMed
20.
go back to reference Brown GA, Firoozbakhsh K, Gehlert RJ (2001) Three-dimensional CT modelling versus traditional radiology techniques in treatment of acetabular fractures. Iowa Orthop J 21:20–24PubMedPubMedCentral Brown GA, Firoozbakhsh K, Gehlert RJ (2001) Three-dimensional CT modelling versus traditional radiology techniques in treatment of acetabular fractures. Iowa Orthop J 21:20–24PubMedPubMedCentral
21.
go back to reference Brown GA, Milner B, Firoozbakhsh K (2002) Application of computer-generated stereolithography and interpositioning template in acetabular fractures: a report of eight cases. J Orthop Trauma 16:347–352CrossRefPubMed Brown GA, Milner B, Firoozbakhsh K (2002) Application of computer-generated stereolithography and interpositioning template in acetabular fractures: a report of eight cases. J Orthop Trauma 16:347–352CrossRefPubMed
22.
go back to reference Duncan JM, Nahas S, Akhtar K, Daurka J (2015) The use of a 3D printer in preoperative planning for a patient requiring acetabular reconstructive surgery. J Orthop Case Rep 5(1):23–25PubMedPubMedCentral Duncan JM, Nahas S, Akhtar K, Daurka J (2015) The use of a 3D printer in preoperative planning for a patient requiring acetabular reconstructive surgery. J Orthop Case Rep 5(1):23–25PubMedPubMedCentral
25.
go back to reference Matta J (1996) Fractures of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury. J Bone Joint Surg Am 78A:1632–1645CrossRef Matta J (1996) Fractures of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury. J Bone Joint Surg Am 78A:1632–1645CrossRef
Metadata
Title
Evaluation of accuracy of virtual surgical planning for patient-specific pre-contoured plate in acetabular fracture fixation
Authors
Lalit Maini
Tarun Verma
Amit Sharma
Ankur Sharma
Abhishek Mishra
Sunil Jha
Publication date
01-04-2018
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 4/2018
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-018-2868-2

Other articles of this Issue 4/2018

Archives of Orthopaedic and Trauma Surgery 4/2018 Go to the issue