Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 5/2014

01-05-2014 | Trauma Surgery

Laser method for intraoperative evaluation of lower extremity alignment: comparison of a novel technique to CT and a conventional method

Authors: Nael Hawi, Seth Yarboro, Eduardo M. Suero, Emmanouil Liodakis, Rupert Meller, Christian Krettek, Musa Citak

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 5/2014

Login to get access

Abstract

Introduction

Accurate restoration of mechanical alignment is an important factor in reconstructive surgery of the lower extremity. Conventional intraoperative methods, such as using an electrocautery cable, provide only a momentary evaluation of alignment. In this study, we evaluated a novel technique using a laser emitter, which projected the mechanical axis of the lower extremity, providing continuous intraoperative information on alignment.

Materials and methods

Alignment of 16 cadaver lower extremities was measured using the electrocautery cable method, the laser method, and CT scan as the standard measurement. The mechanical axis was defined by a line from the center of the femoral head to the center of the ankle. For simplifying measurements the intersection with the tibial plateau was divided into percentages from the medial border (0 %) to the lateral border (100 %). For using the laser method a laser emitting and laser catching device was developed, which is positioned and centered on the femoral head and the ankle using an image intensifier. By catching the laser on the knee region the actual mechanical axis is marked.

Results

The data demonstrated good correlation of the laser method when compared to the cable method (P = 0.44). Comparison of the average mechanical axis between cable method and CT (P = 0.819) and laser method and CT (P = 0.647) did not show a statistically significant difference. Average radiation time in comparison between cable method and laser method showed a statistically significant difference (P = 0.013), with the laser method requiring more radiation time.

Conclusion

Determination of the mechanical axis during surgery remains a difficult clinical problem. Restoration of alignment is an important prognostic factor for surgical outcome. Based on these data, the laser method represents a simple, yet effective tool for continuous intraoperative evaluation of lower extremity alignment.
Literature
1.
go back to reference Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86(5):682–687PubMedCrossRef Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86(5):682–687PubMedCrossRef
2.
go back to reference Chao EY, Neluheni EV, Hsu RW, Paley D (1994) Biomechanics of malalignment. Orthop Clin North Am 25(3):379–386PubMed Chao EY, Neluheni EV, Hsu RW, Paley D (1994) Biomechanics of malalignment. Orthop Clin North Am 25(3):379–386PubMed
4.
go back to reference Hankemeier S, Hufner T, Wang G, Kendoff D, Zheng G, Richter M, Gosling T, Nolte L, Krettek C (2005) Navigated intraoperative analysis of lower limb alignment. Arch Orthop Trauma Surg 125(8):531–535PubMedCrossRef Hankemeier S, Hufner T, Wang G, Kendoff D, Zheng G, Richter M, Gosling T, Nolte L, Krettek C (2005) Navigated intraoperative analysis of lower limb alignment. Arch Orthop Trauma Surg 125(8):531–535PubMedCrossRef
5.
go back to reference Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am 69(3):332–354PubMed Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am 69(3):332–354PubMed
6.
go back to reference Hoke D, Jafari SM, Orozco F, Ong A (2011) Tibial shaft stress fractures resulting from placement of navigation tracker pins. J Arthroplasty 26(3):504 (e505-508)PubMedCrossRef Hoke D, Jafari SM, Orozco F, Ong A (2011) Tibial shaft stress fractures resulting from placement of navigation tracker pins. J Arthroplasty 26(3):504 (e505-508)PubMedCrossRef
7.
go back to reference Hsu RW, Himeno S, Coventry MB, Chao EY (1990) Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop Relat Res 255:215–227PubMed Hsu RW, Himeno S, Coventry MB, Chao EY (1990) Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop Relat Res 255:215–227PubMed
8.
go back to reference Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73(5):709–714PubMed Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73(5):709–714PubMed
9.
go back to reference Jung HJ, Jung YB, Song KS, Park SJ, Lee JS (2007) Fractures associated with computer-navigated total knee arthroplasty. A report of two cases. J Bone Joint Surg Am 89(10):2280–2284PubMedCrossRef Jung HJ, Jung YB, Song KS, Park SJ, Lee JS (2007) Fractures associated with computer-navigated total knee arthroplasty. A report of two cases. J Bone Joint Surg Am 89(10):2280–2284PubMedCrossRef
10.
go back to reference Krettek C, Miclau T, Grun O, Schandelmaier P, Tscherne H (1998) Intraoperative control of axes, rotation and length in femoral and tibial fractures technical note. Injury 29(Suppl 3):C29–C39PubMedCrossRef Krettek C, Miclau T, Grun O, Schandelmaier P, Tscherne H (1998) Intraoperative control of axes, rotation and length in femoral and tibial fractures technical note. Injury 29(Suppl 3):C29–C39PubMedCrossRef
11.
go back to reference Liodakis E, Kenawey M, Liodaki E, Mommsen P, Krettek C, Hankemeier S (2010) The axis-board: an alternative to the cable technique for intraoperative assessment of lower limb alignment. Technol Health Care 18(3):165–171PubMed Liodakis E, Kenawey M, Liodaki E, Mommsen P, Krettek C, Hankemeier S (2010) The axis-board: an alternative to the cable technique for intraoperative assessment of lower limb alignment. Technol Health Care 18(3):165–171PubMed
12.
go back to reference Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59(1):77–79PubMed Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59(1):77–79PubMed
13.
go back to reference Massai F, Conteduca F, Vadala A, Iorio R, Basiglini L, Ferretti A (2010) Tibial stress fracture after computer-navigated total knee arthroplasty. J Orthop Traumatol 11(2):123–127PubMedCentralPubMedCrossRef Massai F, Conteduca F, Vadala A, Iorio R, Basiglini L, Ferretti A (2010) Tibial stress fracture after computer-navigated total knee arthroplasty. J Orthop Traumatol 11(2):123–127PubMedCentralPubMedCrossRef
14.
go back to reference Matthews LS, Goldstein SA, Malvitz TA, Katz BP, Kaufer H (1988) Proximal tibial osteotomy. Factors that influence the duration of satisfactory function. Clin Orthop Relat Res 229:193–200PubMed Matthews LS, Goldstein SA, Malvitz TA, Katz BP, Kaufer H (1988) Proximal tibial osteotomy. Factors that influence the duration of satisfactory function. Clin Orthop Relat Res 229:193–200PubMed
15.
go back to reference Paley D, Herzenberg JE, Tetsworth K, McKie J, Bhave A (1994) Deformity planning for frontal and sagittal plane corrective osteotomies. Orthop Clin North Am 25(3):425–465PubMed Paley D, Herzenberg JE, Tetsworth K, McKie J, Bhave A (1994) Deformity planning for frontal and sagittal plane corrective osteotomies. Orthop Clin North Am 25(3):425–465PubMed
16.
go back to reference Paley D, Tetsworth K (1992) Mechanical axis deviation of the lower limbs. Preoperative planning of multiapical frontal plane angular and bowing deformities of the femur and tibia. Clin Orthop Relat Res 280:65–71PubMed Paley D, Tetsworth K (1992) Mechanical axis deviation of the lower limbs. Preoperative planning of multiapical frontal plane angular and bowing deformities of the femur and tibia. Clin Orthop Relat Res 280:65–71PubMed
17.
go back to reference Papachristou G (2004) Photoelastic study of the internal and contact stresses on the knee joint before and after osteotomy. Arch Orthop Trauma Surg 124(5):288–297PubMedCrossRef Papachristou G (2004) Photoelastic study of the internal and contact stresses on the knee joint before and after osteotomy. Arch Orthop Trauma Surg 124(5):288–297PubMedCrossRef
18.
go back to reference Quack VM, Kathrein S, Rath B, Tingart M, Luring C (2012) Computer-assisted navigation in total knee arthroplasty: a review of literature. Biomed Tech (Berl) 57(4):269–275CrossRef Quack VM, Kathrein S, Rath B, Tingart M, Luring C (2012) Computer-assisted navigation in total knee arthroplasty: a review of literature. Biomed Tech (Berl) 57(4):269–275CrossRef
19.
go back to reference Saleh M, Harriman P, Edwards DJ (1991) A radiological method for producing precise limb alignment. J Bone Joint Surg Br 73(3):515–516PubMed Saleh M, Harriman P, Edwards DJ (1991) A radiological method for producing precise limb alignment. J Bone Joint Surg Br 73(3):515–516PubMed
20.
go back to reference Sharma L, Song J, Felson DT, Cahue S, Shamiyeh E, Dunlop DD (2001) The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA 286(2):188–195PubMedCrossRef Sharma L, Song J, Felson DT, Cahue S, Shamiyeh E, Dunlop DD (2001) The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA 286(2):188–195PubMedCrossRef
21.
go back to reference Sprenger TR, Doerzbacher JF (2003) Tibial osteotomy for the treatment of varus gonarthrosis. Survival and failure analysis to twenty-two years. J Bone Joint Surg Am 85(A (3)):469–474PubMed Sprenger TR, Doerzbacher JF (2003) Tibial osteotomy for the treatment of varus gonarthrosis. Survival and failure analysis to twenty-two years. J Bone Joint Surg Am 85(A (3)):469–474PubMed
22.
go back to reference Ziahosseini K, Doris JP, Turner GS (2010) Laser eye injuries. Maculopathy from handheld green diode laser pointer. BMJ 340:c2982. doi:10.1136/bmj.c2982 (Comment in: Laser eye injuries. Further warnings about laser pointers, [BMJ, PMID 20530564]) Ziahosseini K, Doris JP, Turner GS (2010) Laser eye injuries. Maculopathy from handheld green diode laser pointer. BMJ 340:c2982. doi:10.​1136/​bmj.​c2982 (Comment in: Laser eye injuries. Further warnings about laser pointers, [BMJ, PMID 20530564])
Metadata
Title
Laser method for intraoperative evaluation of lower extremity alignment: comparison of a novel technique to CT and a conventional method
Authors
Nael Hawi
Seth Yarboro
Eduardo M. Suero
Emmanouil Liodakis
Rupert Meller
Christian Krettek
Musa Citak
Publication date
01-05-2014
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 5/2014
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-014-1964-1

Other articles of this Issue 5/2014

Archives of Orthopaedic and Trauma Surgery 5/2014 Go to the issue