Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 12/2009

01-12-2009 | Trauma Surgery

Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures

Authors: Chang-Wug Oh, Jung-Jae Kim, Young-Soo Byun, Jong-Keon Oh, Joon-Woo Kim, Shin-Yoon Kim, Byung-Chul Park, Hyun-Joo Lee

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 12/2009

Login to get access

Abstract

Background

Intramedullary nailing is a mainstay in the treatment of subtrochanteric femoral fractures. But nailing is often unsuitable for difficult fracture patterns with comminution or when the medullary canal is narrow. The purpose of this study was to clarify the efficacy of minimally invasive plate osteosynthesis (MIPO) with locking compression plate in the treatment of subtrochanteric fractures.

Methods

Twenty patients with subtrochanteric fractures (mean age 49.6 years) were prospectively treated using the MIPO technique using a locking plate. Indications of procedure were fractures with the greater trochanter or medial comminution, and multiple injured patients with a narrow femoral canal. According to the AO/OTA classification, there were three of type A, eight of type B, and nine of type C.

Results

All healed without bone graft, at an average of 20.1 weeks (range 16–32). With the exception of two patients with minor internal rotation deformity and one patient with 1 cm of shortening, most achieved acceptable alignment. All patients were able to walk with no or only a slight limp, and median Merle d’Aubigne score was 17.3 (15–18). Four patients complained of a slight pain in the trochanteric area due to plate prominence.

Summary

The MIPO technique with a locking plate provides an alternative method for fixing subtrochanteric femur fractures, when IM nailing is inappropriate. This technique provides stable fixation, with a high union rate and a minimal complication rate.
Literature
1.
2.
go back to reference Blatter G, Janssen M (1994) Treatment of subtrochanteric fractures of the femur: reduction on the traction table and fixation with dynamic condylar screw. Arch Orthop Trauma Surg 113:138–141CrossRefPubMed Blatter G, Janssen M (1994) Treatment of subtrochanteric fractures of the femur: reduction on the traction table and fixation with dynamic condylar screw. Arch Orthop Trauma Surg 113:138–141CrossRefPubMed
3.
go back to reference Celebi L, Can M, Muratli HH, Yagmurlu MF, Yuksel HY, Bicimoğlu A (2006) Indirect reduction and biological internal fixation of comminuted subtrochanteric fractures of the femur. Injury 37:740–750CrossRefPubMed Celebi L, Can M, Muratli HH, Yagmurlu MF, Yuksel HY, Bicimoğlu A (2006) Indirect reduction and biological internal fixation of comminuted subtrochanteric fractures of the femur. Injury 37:740–750CrossRefPubMed
4.
go back to reference Craig NJ, Sivaji C, Maffulli N (2001) Review article. Subtrochanteric fractures. A review of treatment options. Bull Hosp Jt Dis 60:35–46PubMed Craig NJ, Sivaji C, Maffulli N (2001) Review article. Subtrochanteric fractures. A review of treatment options. Bull Hosp Jt Dis 60:35–46PubMed
5.
go back to reference Datir SP, Bedi GS, Curwen CH (2004) Unreamed femoral nail with spiral blade in subtrochanteric fractures: experience of 55 cases. Injury 35:191–195CrossRefPubMed Datir SP, Bedi GS, Curwen CH (2004) Unreamed femoral nail with spiral blade in subtrochanteric fractures: experience of 55 cases. Injury 35:191–195CrossRefPubMed
6.
go back to reference de Vries JS, Kloen P, Borens O, Marti RK, Helfet DL (2006) Treatment of subtrochanteric nonunions. Injury 37:203–211CrossRefPubMed de Vries JS, Kloen P, Borens O, Marti RK, Helfet DL (2006) Treatment of subtrochanteric nonunions. Injury 37:203–211CrossRefPubMed
7.
go back to reference Garnavos C, Peterman A, Howard PW (1999) The treatment of difficult proximal femoral fractures with the Russell–Taylor reconstruction nail. Injury 30:407–415CrossRefPubMed Garnavos C, Peterman A, Howard PW (1999) The treatment of difficult proximal femoral fractures with the Russell–Taylor reconstruction nail. Injury 30:407–415CrossRefPubMed
8.
go back to reference Gerber C, Mast JW, Ganz R (1990) Biological internal fixation of fractures. Arch Orthop Trauma Surg 109:295–303CrossRefPubMed Gerber C, Mast JW, Ganz R (1990) Biological internal fixation of fractures. Arch Orthop Trauma Surg 109:295–303CrossRefPubMed
9.
go back to reference Haidukewych GJ, Berry DJ (2004) Nonunion of fractures of the subtrochanteric region of the femur. Clin Orthop 419:185–188CrossRefPubMed Haidukewych GJ, Berry DJ (2004) Nonunion of fractures of the subtrochanteric region of the femur. Clin Orthop 419:185–188CrossRefPubMed
10.
go back to reference Higgins TF, Pittman G, Hines J, Bachus KN (2007) Biomechanical analysis of distal femur fracture fixation: fixed-angle screw-plate construct versus condylar blade plate. J Orthop Trauma 21:43–46CrossRefPubMed Higgins TF, Pittman G, Hines J, Bachus KN (2007) Biomechanical analysis of distal femur fracture fixation: fixed-angle screw-plate construct versus condylar blade plate. J Orthop Trauma 21:43–46CrossRefPubMed
11.
go back to reference Kang S, McAndrew MP, Johnson KD (1995) The reconstruction locked nail for complex fractures of the proximal femur. J Orthop Trauma 9:453–463CrossRefPubMed Kang S, McAndrew MP, Johnson KD (1995) The reconstruction locked nail for complex fractures of the proximal femur. J Orthop Trauma 9:453–463CrossRefPubMed
12.
go back to reference Krettek C, Miclau T, Grun O, Schandelmaier P, Tscherne H (1998) Intraoperative control of axes, rotation and length in femoral and tibial fractures-technical note. Injury 29(3):C29–C39CrossRefPubMed Krettek C, Miclau T, Grun O, Schandelmaier P, Tscherne H (1998) Intraoperative control of axes, rotation and length in femoral and tibial fractures-technical note. Injury 29(3):C29–C39CrossRefPubMed
13.
go back to reference Kulkarni SS, Moran CG (2003) Results of dynamic condylar screw for subtrochanteric fractures. Injury 34:117–122CrossRefPubMed Kulkarni SS, Moran CG (2003) Results of dynamic condylar screw for subtrochanteric fractures. Injury 34:117–122CrossRefPubMed
14.
go back to reference Matta JM, Anderson LM, Epstein HC, Hendricks P (1986) Fractures of the acetabulum. A retrospective analysis. Clin Orthop 205:230–240PubMed Matta JM, Anderson LM, Epstein HC, Hendricks P (1986) Fractures of the acetabulum. A retrospective analysis. Clin Orthop 205:230–240PubMed
15.
go back to reference Menezes DF, Gamulin A, Noesberger B (2005) Is the proximal femoral nail a suitable implant for treatment of all trochanteric fractures? Clin Orthop 439:221–227CrossRefPubMed Menezes DF, Gamulin A, Noesberger B (2005) Is the proximal femoral nail a suitable implant for treatment of all trochanteric fractures? Clin Orthop 439:221–227CrossRefPubMed
16.
go back to reference Nungu KS, Olerud C, Rehnberg L (1993) Treatment of subtrochanteric fractures with the AO dynamic condylar screw. Injury 24:90–92CrossRefPubMed Nungu KS, Olerud C, Rehnberg L (1993) Treatment of subtrochanteric fractures with the AO dynamic condylar screw. Injury 24:90–92CrossRefPubMed
17.
go back to reference Oh CW, Song HR, Jeon IH, Min WK, Park BC (2007) Nail-assisted percutaneous plating of pediatric femoral fractures. Clin Orthop 456:176–181CrossRefPubMed Oh CW, Song HR, Jeon IH, Min WK, Park BC (2007) Nail-assisted percutaneous plating of pediatric femoral fractures. Clin Orthop 456:176–181CrossRefPubMed
18.
go back to reference Pai CH (1996) Dynamic condylar screw for subtrochanteric fractures with greater trochanteric extension. J Orthop Trauma 10:317–322CrossRefPubMed Pai CH (1996) Dynamic condylar screw for subtrochanteric fractures with greater trochanteric extension. J Orthop Trauma 10:317–322CrossRefPubMed
19.
go back to reference Pakuts AJ (2004) Unstable subtrochanteric fractures–gamma nail versus dynamic condylar screw. Int Orthop 28:21–24CrossRefPubMed Pakuts AJ (2004) Unstable subtrochanteric fractures–gamma nail versus dynamic condylar screw. Int Orthop 28:21–24CrossRefPubMed
20.
go back to reference Parker MJ, Dutta BK, Sivaji C, Pryor GA (1997) Subtrochanteric fractures of the femur. Injury 28:91–95CrossRefPubMed Parker MJ, Dutta BK, Sivaji C, Pryor GA (1997) Subtrochanteric fractures of the femur. Injury 28:91–95CrossRefPubMed
21.
go back to reference Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 84:1093–1110CrossRefPubMed Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 84:1093–1110CrossRefPubMed
22.
go back to reference Pryce Lewis JR, Ashcroft GP (2007) Reverse LISS plating for proximal segmental femoral fractures in the polytrauma patient: a case report. Injury 38:235–239CrossRefPubMed Pryce Lewis JR, Ashcroft GP (2007) Reverse LISS plating for proximal segmental femoral fractures in the polytrauma patient: a case report. Injury 38:235–239CrossRefPubMed
23.
go back to reference Saarenpää I, Heikkinen T, Jalovaara P (2007) Treatment of subtrochanteric fractures. A comparison of the Gamma nail and the dynamic hip screw: short-term outcome in 58 patients. Int Orthop 31:65–70CrossRefPubMed Saarenpää I, Heikkinen T, Jalovaara P (2007) Treatment of subtrochanteric fractures. A comparison of the Gamma nail and the dynamic hip screw: short-term outcome in 58 patients. Int Orthop 31:65–70CrossRefPubMed
24.
go back to reference Sanders R, Regazonni P (1989) Treatment of subtrochanteric femur fractures using the dynamic condylar screw. J Orthop Trauma 3:206–213PubMedCrossRef Sanders R, Regazonni P (1989) Treatment of subtrochanteric femur fractures using the dynamic condylar screw. J Orthop Trauma 3:206–213PubMedCrossRef
25.
go back to reference Siebenrock KA, Muller U, Ganz R (1998) Indirect reduction with a condylar blade plate for osteosynthesis of subtrochanteric femoral fractures. Injury 29(3):C7–C15CrossRefPubMed Siebenrock KA, Muller U, Ganz R (1998) Indirect reduction with a condylar blade plate for osteosynthesis of subtrochanteric femoral fractures. Injury 29(3):C7–C15CrossRefPubMed
27.
go back to reference Vaidya SV, Dholakia DB, Chatterjee A (2003) The use of a dynamic condylar screw and biological reduction techniques for subtrochanteric femur fracture. Injury 34:123–128CrossRefPubMed Vaidya SV, Dholakia DB, Chatterjee A (2003) The use of a dynamic condylar screw and biological reduction techniques for subtrochanteric femur fracture. Injury 34:123–128CrossRefPubMed
28.
go back to reference Valverde JA, Alonso MG, Porro JG, Rueda D, Larrauri PM, Soler JJ (1998) Use of the gamma nail in the treatment of fractures of the proximal femur. Clin Orthop 350:56–61PubMed Valverde JA, Alonso MG, Porro JG, Rueda D, Larrauri PM, Soler JJ (1998) Use of the gamma nail in the treatment of fractures of the proximal femur. Clin Orthop 350:56–61PubMed
29.
go back to reference Warwick DJ, Crichlow TP, Langkamer VG, Jackson M (1995) The dynamic condylar screw in the management of subtrochanteric fractures of the femur. Injury 26:241–244CrossRefPubMed Warwick DJ, Crichlow TP, Langkamer VG, Jackson M (1995) The dynamic condylar screw in the management of subtrochanteric fractures of the femur. Injury 26:241–244CrossRefPubMed
30.
go back to reference Yoshino N, Watanabe Y, Takenaka N, Watanabe N, Fukuda Y, Fujita N, Maruyama N, Sumiyoshi H, Takai S (2006) Implant failure of long Gamma nail in a patient with intertrochanteric-subtrochanteric fracture. J Orthop Sci 11:638–643CrossRefPubMed Yoshino N, Watanabe Y, Takenaka N, Watanabe N, Fukuda Y, Fujita N, Maruyama N, Sumiyoshi H, Takai S (2006) Implant failure of long Gamma nail in a patient with intertrochanteric-subtrochanteric fracture. J Orthop Sci 11:638–643CrossRefPubMed
Metadata
Title
Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures
Authors
Chang-Wug Oh
Jung-Jae Kim
Young-Soo Byun
Jong-Keon Oh
Joon-Woo Kim
Shin-Yoon Kim
Byung-Chul Park
Hyun-Joo Lee
Publication date
01-12-2009
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 12/2009
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-009-0815-y

Other articles of this Issue 12/2009

Archives of Orthopaedic and Trauma Surgery 12/2009 Go to the issue