Abstract

The standard technique for restoring footprint after full-thickness tears of the rotator cuff includes double-row or transosseous-equivalent techniques. However, the anatomically typical bird’s beak shape and profile of tendon insertion may not be originally restored and biomechanics may be altered. In this report, the authors describe a technique that involves creating two intratendinous stitches at different levels of the torn tendon. The first passes through the bursal-side layer, the second stitch through the joint-side layer. Both stitches may be performed in mattress suture configuration. The anchorage is performed by knotless anchors in order to avoid knots lying within the insertion area. The footprint is restored first medially then laterally by the use of double-row principles. The joint-side suture is anchored within the medially placed anchor. The bursal-side suture is anchored by a laterally placed anchor. The anatomic insertion and restoration of the shape and profile may be enabled by the described double-layer suture technique. Using a double-layer double-row repair may potentially improve functional results of rotator cuff repair constructs.
Literature
1.
go back to reference Bhatia DN, de Beer JF, van Rooyen KS (2007) The bony partial articular surface tendon avulsion lesion: an arthroscopic technique for fixation of the partially avulsed greater tuberosity fracture. Arthroscopy 23(7):786.e1–786.e6 Bhatia DN, de Beer JF, van Rooyen KS (2007) The bony partial articular surface tendon avulsion lesion: an arthroscopic technique for fixation of the partially avulsed greater tuberosity fracture. Arthroscopy 23(7):786.e1–786.e6
2.
go back to reference Bhatia DN, van Rooyen KS, de Beer JF (2007) The “paraglider-wing” sign: an arthroscopic indicator of partial-thickness bursal-surface tears of the supraspinatus tendon. Knee Surg Sports Traumatol Arthrosc 15(6):790–793PubMedCrossRef Bhatia DN, van Rooyen KS, de Beer JF (2007) The “paraglider-wing” sign: an arthroscopic indicator of partial-thickness bursal-surface tears of the supraspinatus tendon. Knee Surg Sports Traumatol Arthrosc 15(6):790–793PubMedCrossRef
3.
go back to reference Burkhart SS (1994) Reconciling the paradox of rotator cuff repair versus debridement: a unified biomechanical rationale for the treatment of rotator cuff tears. Arthroscopy 10(1):4–19PubMed Burkhart SS (1994) Reconciling the paradox of rotator cuff repair versus debridement: a unified biomechanical rationale for the treatment of rotator cuff tears. Arthroscopy 10(1):4–19PubMed
4.
go back to reference Burkhart SS (1995) The deadman theory of suture anchors: observations along a south Texas fence line. Arthroscopy 11(1):119–123PubMed Burkhart SS (1995) The deadman theory of suture anchors: observations along a south Texas fence line. Arthroscopy 11(1):119–123PubMed
5.
go back to reference Clark JM, Harryman DT 2nd (1992) Tendons, ligaments, and capsule of the rotator cuff. Gross and microscopic anatomy. J Bone Joint Surg Am 74(5):713–725PubMed Clark JM, Harryman DT 2nd (1992) Tendons, ligaments, and capsule of the rotator cuff. Gross and microscopic anatomy. J Bone Joint Surg Am 74(5):713–725PubMed
6.
go back to reference Curtis AS, Burbank KM, Tierney JJ, Scheller AD, Curran AR (2006) The insertional footprint of the rotator cuff: an anatomic study. Arthroscopy 22(6):609.e1 Curtis AS, Burbank KM, Tierney JJ, Scheller AD, Curran AR (2006) The insertional footprint of the rotator cuff: an anatomic study. Arthroscopy 22(6):609.e1
7.
go back to reference Fukuda H, Hamada K, Nakajima T, Yamada N, Tomonaga A, Goto M (1996) Partial-thickness tears of the rotator cuff. A clinicopathological review based on 66 surgically verified cases. Int Orthop 20(4):257–265PubMedCrossRef Fukuda H, Hamada K, Nakajima T, Yamada N, Tomonaga A, Goto M (1996) Partial-thickness tears of the rotator cuff. A clinicopathological review based on 66 surgically verified cases. Int Orthop 20(4):257–265PubMedCrossRef
8.
go back to reference Huang CY, Wang VM, Pawluk RJ, Bucchieri JS, Levine WN, Bigliani LU, Mow VC, Flatow EL (2005) Inhomogeneous mechanical behavior of the human supraspinatus tendon under uniaxial loading. J Orthop Res 23(4):924–930PubMedCrossRef Huang CY, Wang VM, Pawluk RJ, Bucchieri JS, Levine WN, Bigliani LU, Mow VC, Flatow EL (2005) Inhomogeneous mechanical behavior of the human supraspinatus tendon under uniaxial loading. J Orthop Res 23(4):924–930PubMedCrossRef
9.
go back to reference Itoi E, Berglund LJ, Grabowski JJ, Schultz FM, Growney ES, Morrey BF, An KN (1995) Tensile properties of the supraspinatus tendon. J Orthop Res 13(4):578–584PubMedCrossRef Itoi E, Berglund LJ, Grabowski JJ, Schultz FM, Growney ES, Morrey BF, An KN (1995) Tensile properties of the supraspinatus tendon. J Orthop Res 13(4):578–584PubMedCrossRef
10.
go back to reference Kim SY, Boynton EL, Ravichandiran K, Fung LY, Bleakney R, Agur AM (2007) Three-dimensional study of the musculotendinous architecture of supraspinatus and its functional correlations. Clin Anat 20(6):648–655PubMedCrossRef Kim SY, Boynton EL, Ravichandiran K, Fung LY, Bleakney R, Agur AM (2007) Three-dimensional study of the musculotendinous architecture of supraspinatus and its functional correlations. Clin Anat 20(6):648–655PubMedCrossRef
11.
go back to reference Lo IK, Burkhart SS (2003) Double-row arthroscopic rotator cuff repair: re-establishing the footprint of the rotator cuff. Arthroscopy 19(9):1035–1042PubMedCrossRef Lo IK, Burkhart SS (2003) Double-row arthroscopic rotator cuff repair: re-establishing the footprint of the rotator cuff. Arthroscopy 19(9):1035–1042PubMedCrossRef
12.
go back to reference Meier SW, Meier JD (2006) Rotator cuff repair: the effect of double-row fixation on three-dimensional repair site. J Shoulder Elbow Surg 15(6):691–696PubMedCrossRef Meier SW, Meier JD (2006) Rotator cuff repair: the effect of double-row fixation on three-dimensional repair site. J Shoulder Elbow Surg 15(6):691–696PubMedCrossRef
13.
go back to reference Park MC, Tibone JE, ElAttrache NS, Ahmad CS, Jun BJ, Lee TQ (2007) Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg 16(4):469–476PubMedCrossRef Park MC, Tibone JE, ElAttrache NS, Ahmad CS, Jun BJ, Lee TQ (2007) Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg 16(4):469–476PubMedCrossRef
14.
go back to reference Reilly P, Amis AA, Wallace AL, Emery RJ (2003) Mechanical factors in the initiation and propagation of tears of the rotator cuff. Quantification of strains of the supraspinatus tendon in vitro. J Bone Joint Surg Br 85(4):594–599PubMedCrossRef Reilly P, Amis AA, Wallace AL, Emery RJ (2003) Mechanical factors in the initiation and propagation of tears of the rotator cuff. Quantification of strains of the supraspinatus tendon in vitro. J Bone Joint Surg Br 85(4):594–599PubMedCrossRef
15.
go back to reference Spencer EE (2007) Double row double lamina arthroscopic rotatore cuff repair. Tech Shoulder Elbow Surg 8(3):135–140CrossRef Spencer EE (2007) Double row double lamina arthroscopic rotatore cuff repair. Tech Shoulder Elbow Surg 8(3):135–140CrossRef
16.
go back to reference Sugaya H, Maeda K, Matsuki K, Moriishi J (2005) Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation. Arthroscopy 21(11):1307–1316PubMed Sugaya H, Maeda K, Matsuki K, Moriishi J (2005) Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation. Arthroscopy 21(11):1307–1316PubMed
17.
go back to reference Sugaya H, Maeda K, Matsuki K, Moriishi J (2007) Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair. A prospective outcome study. J Bone Joint Surg Am 89(5):953–960PubMedCrossRef Sugaya H, Maeda K, Matsuki K, Moriishi J (2007) Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair. A prospective outcome study. J Bone Joint Surg Am 89(5):953–960PubMedCrossRef
18.
go back to reference Wolff AB, Magit DP, Miller SR, Wyman J, Sethi PM (2006) Arthroscopic fixation of bursal-sided rotator cuff tears. Arthroscopy 22(11):1247.e1–1247.e4 Wolff AB, Magit DP, Miller SR, Wyman J, Sethi PM (2006) Arthroscopic fixation of bursal-sided rotator cuff tears. Arthroscopy 22(11):1247.e1–1247.e4
19.
go back to reference Yoo JC, Ahn JH, Lee SH, Kim JH (2007) Arthroscopic full-layer repair of bursal-side partial-thickness rotator cuff tears: a small-window technique. Arthroscopy 23(8):903.e1–903.e4 Yoo JC, Ahn JH, Lee SH, Kim JH (2007) Arthroscopic full-layer repair of bursal-side partial-thickness rotator cuff tears: a small-window technique. Arthroscopy 23(8):903.e1–903.e4
Metadata
Title
Knotless anatomic double-layer double-row rotator cuff repair: a novel technique re-establishing footprint and shape of full-thickness tears
Authors
Pierre Hepp
Thomas Engel
Georg Osterhoff
Bastian Marquass
Christoph Josten
Publication date
01-08-2009
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 8/2009
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-008-0625-7

Other articles of this Issue 8/2009

Archives of Orthopaedic and Trauma Surgery 8/2009 Go to the issue