Radiographic and magnetic resonance imaging findings of polylevolactic acid screws after rotational acetabular osteotomy

Authors: Katsuhiko Maezawa, Masahiko Nozawa, Keiji Matsuda, Kaoru Mori, Fumiyo Enomoto, Katsuo Shitoto, Hisashi Kurosawa

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 7/2004

Login to get access

Abstract

Introduction

Biodegradable polylevolactic acid implants have become more commonly used for the treatment of fractures and osteotomies over the past few years. In the present study, the biocompatibility and degradation of polylevolactide screws used for rotational acetabular osteotomy were assessed on the basis of radiographic and MRI findings.

Materials and methods

Forty-nine hips of 47 patients were analyzed for this study. The average age of the patients at the time of surgery was 38.0 years (range 18–62 years). The original diagnosis was osteoarthritis in 43 hips and osteonecrosis in 6 hips. The mean duration of follow-up was 2.8 years (range 1.5–5.5 years). Anteroposterior radiographs obtained at 1 week, 6 months, 1 year after the operation, as well as the most recent radiographs, were used to assess bony union, the radiolucent tract of each screw, and the sclerotic rim around each screw. Fifteen patients were chosen randomly to undergo MRI.

Results

Union of the osteotomized surfaces occurred in all patients within 6 months of surgery. Radiographs showed no osteolysis, no formation of bone cysts, and no displacement of the osteotomized acetabulum in any of the 49 hips. None of the patients was found to have any complications caused by problems with the biocompatibility of the implants. At the final postoperative examination, a central radiolucent tract and a sclerotic rim around the screws were seen in 34/49 hips (69%) and 23/49 hips (47%), respectively. On MRI findings, we were able to detect significant resorption of the screws in two patients after 1.2 and 1.7 years of follow-up. Though localized low-intensity areas on T1-weighted images and high-intensity areas on T2-weighted images were observed at the top of the screws in 5 patients, there was no development of pain, tenderness, or a sinus during the follow-up period.

Conclusion

Although absorption of polylevolactic acid screws did not occur in a large majority of cases, rotational acetabular osteotomy appears to be a good indication for the use of polylevolactic acid screws.
Literature
1.
go back to reference Bergsma JE, Bruijn WC de, Rozema FR, Bos RR, Boering G (1995) Late degradation tissue response to poly (L-lactide) bone plates and screws. Biomaterials 16:25–31PubMed Bergsma JE, Bruijn WC de, Rozema FR, Bos RR, Boering G (1995) Late degradation tissue response to poly (L-lactide) bone plates and screws. Biomaterials 16:25–31PubMed
2.
go back to reference Bostman OM, Pihlajamaki HK (2000) Adverse tissue reactions to bioabsorbable fixation devices. Clin Othop 371:216–227CrossRef Bostman OM, Pihlajamaki HK (2000) Adverse tissue reactions to bioabsorbable fixation devices. Clin Othop 371:216–227CrossRef
3.
go back to reference Bostman OM, Pihlajamki HK (1998) Late foreign-body reaction to an intraosseous bioabsorbable polylactic acid screw. J Bone Joint Surg Am 80:1791–1794PubMed Bostman OM, Pihlajamki HK (1998) Late foreign-body reaction to an intraosseous bioabsorbable polylactic acid screw. J Bone Joint Surg Am 80:1791–1794PubMed
4.
go back to reference Bostman OM, Pihlajamaki HK, Partio EK, Rokkanen PU (1995) Clinical biocompatibility and degradation of polylevolactide screws in the ankle. Clin Orthop 320:101–109PubMed Bostman OM, Pihlajamaki HK, Partio EK, Rokkanen PU (1995) Clinical biocompatibility and degradation of polylevolactide screws in the ankle. Clin Orthop 320:101–109PubMed
5.
go back to reference Casteleyn PP, Handelbelg F, Hantjens P (1992) Biodegradable rods versus Kirschner wire fixation of wrist fractures, a randomized trial. J Bone Joint Surg Br 74:858–861PubMed Casteleyn PP, Handelbelg F, Hantjens P (1992) Biodegradable rods versus Kirschner wire fixation of wrist fractures, a randomized trial. J Bone Joint Surg Br 74:858–861PubMed
6.
go back to reference Hoffmann R, Krettek C, Hetkamper A, Haas N, Tscherne H (1992) Osteo-synsthese distaler Radiusfrakturen mit biodegradablen Fraktur-stiften. Zweijahresergebnisse. Unfallchirurg 95:99–105PubMed Hoffmann R, Krettek C, Hetkamper A, Haas N, Tscherne H (1992) Osteo-synsthese distaler Radiusfrakturen mit biodegradablen Fraktur-stiften. Zweijahresergebnisse. Unfallchirurg 95:99–105PubMed
7.
go back to reference Hovis WD, Bucholz RW (1997) Polyglycolide bioabsorbable screws in the treatment of ankle fractures. Foot Ankle Int 18:128–131PubMed Hovis WD, Bucholz RW (1997) Polyglycolide bioabsorbable screws in the treatment of ankle fractures. Foot Ankle Int 18:128–131PubMed
8.
go back to reference Ito H, Minami A, Tanino H, Matsuno T (2002) Fixation with poly-L-lactic acid screws in hip osteotomy: 68 hips followed for 18–46 months. Acta Orthop Scand 73:60–64CrossRefPubMed Ito H, Minami A, Tanino H, Matsuno T (2002) Fixation with poly-L-lactic acid screws in hip osteotomy: 68 hips followed for 18–46 months. Acta Orthop Scand 73:60–64CrossRefPubMed
9.
go back to reference Lajtai G, Schmiedhuber G, Unger F, Aitzetmller G, Klein M, Noszian I, Orthner E (2001) Bone tunnel remodeling at the site of biodegradable interference screws used for anterior cruciate ligament reconstruction: 5-year follow-up. Arthroscopy 17:597–602PubMed Lajtai G, Schmiedhuber G, Unger F, Aitzetmller G, Klein M, Noszian I, Orthner E (2001) Bone tunnel remodeling at the site of biodegradable interference screws used for anterior cruciate ligament reconstruction: 5-year follow-up. Arthroscopy 17:597–602PubMed
10.
go back to reference Martineck V, Friedrich NF (1999) Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation. Arthroscopy 15:317–320 Martineck V, Friedrich NF (1999) Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation. Arthroscopy 15:317–320
11.
go back to reference Matsusue Y, Hanafusa S, Yamamuro T, Shikinami Y, Ikada Y (1995) Tissue reaction of bioabsorbable ultra high strength poly (L-lactide) rod. A long-term study in rabbits. Clin Orthop 317:246–253PubMed Matsusue Y, Hanafusa S, Yamamuro T, Shikinami Y, Ikada Y (1995) Tissue reaction of bioabsorbable ultra high strength poly (L-lactide) rod. A long-term study in rabbits. Clin Orthop 317:246–253PubMed
12.
go back to reference Nakamura S, Takatori Y, Morimoto S, et al (1999) Rotational acetabular osteotomy using biodegradable internal fixation. Int Orthop 23:148–149CrossRefPubMed Nakamura S, Takatori Y, Morimoto S, et al (1999) Rotational acetabular osteotomy using biodegradable internal fixation. Int Orthop 23:148–149CrossRefPubMed
13.
go back to reference Ninomiya S, Tagawa H (1984) Rotational acetabular osteotomy for the dysplastic hip. J Bone Joint Surg Am 66:430–436 Ninomiya S, Tagawa H (1984) Rotational acetabular osteotomy for the dysplastic hip. J Bone Joint Surg Am 66:430–436
14.
go back to reference Nozawa M, Shitoto K, Matsuda K, Maezawa K, Kurosawa H (2002) Rotational acetabular osteotomy for acetabular dysplasia. J Bone Joint Surg Br 84:59–65CrossRefPubMed Nozawa M, Shitoto K, Matsuda K, Maezawa K, Kurosawa H (2002) Rotational acetabular osteotomy for acetabular dysplasia. J Bone Joint Surg Br 84:59–65CrossRefPubMed
15.
go back to reference Rokkanen PU (1991) Absorbable materials in orthopaedic surgery. Ann Med 23:109–115PubMed Rokkanen PU (1991) Absorbable materials in orthopaedic surgery. Ann Med 23:109–115PubMed
16.
go back to reference Simon JA, Ricci JL, Di Cesare PE (1997) Bioresorbable fracture fixation in orthopedics: a comprehensive review. Part II. Clinical studies. Am J Orthop 26:754–762PubMed Simon JA, Ricci JL, Di Cesare PE (1997) Bioresorbable fracture fixation in orthopedics: a comprehensive review. Part II. Clinical studies. Am J Orthop 26:754–762PubMed
17.
go back to reference Takizawa T, Akizuki S, Horiuchi H, Yasukawa Y (1998) Foreign body gonitis caused by a broken poly-L-lactic acid screw. Arthroscopy 14:329–330PubMed Takizawa T, Akizuki S, Horiuchi H, Yasukawa Y (1998) Foreign body gonitis caused by a broken poly-L-lactic acid screw. Arthroscopy 14:329–330PubMed
18.
go back to reference Warden WH, Friedman R, Teresi LM, Jackson DW (1999) Magnetic resonance imaging of bioabsorbable polylactic acid interference screws during the first 2 years after anterior cruciate ligament reconstruction. Arthroscopy 15:474–480PubMed Warden WH, Friedman R, Teresi LM, Jackson DW (1999) Magnetic resonance imaging of bioabsorbable polylactic acid interference screws during the first 2 years after anterior cruciate ligament reconstruction. Arthroscopy 15:474–480PubMed
19.
go back to reference Yoshino N, Takai S, Watanabe Y, Kamata K, Hirasawa Y (1998) Delayed aseptic swelling after fixation of talar neck fracture with a biodegradable poly-L-lactide rod: case reports. Foot Ankle Int 19:634–637PubMed Yoshino N, Takai S, Watanabe Y, Kamata K, Hirasawa Y (1998) Delayed aseptic swelling after fixation of talar neck fracture with a biodegradable poly-L-lactide rod: case reports. Foot Ankle Int 19:634–637PubMed
Metadata
Title
Radiographic and magnetic resonance imaging findings of polylevolactic acid screws after rotational acetabular osteotomy
Authors
Katsuhiko Maezawa
Masahiko Nozawa
Keiji Matsuda
Kaoru Mori
Fumiyo Enomoto
Katsuo Shitoto
Hisashi Kurosawa
Publication date
01-09-2004
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 7/2004
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-004-0703-4

Other articles of this Issue 7/2004

Archives of Orthopaedic and Trauma Surgery 7/2004 Go to the issue