Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 4/2004

01-05-2004 | Original Article

Simplified MRI sequences for postoperative control of hamstring anterior cruciate ligament reconstruction

Authors: J. D. Agneskirchner, M. Galla, P. Landwehr, H. P. Lobenhoffer

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 4/2004

Login to get access

Abstract

Introduction

Usually, standard radiographs are used for postoperative quality follow-up after ACL reconstruction. However, with the use of hamstring grafts and bioabsorbable implants, accurate assessment of the tunnel and implant position is impossible. The graft and its relation to anatomical landmarks cannot be evaluated directly. MRI is an alternative to radiography, permitting direct graft visualization and 3-dimensional assessment of the tunnel position, but it is expensive and time consuming for routine use. The aim of this study was to develop a simplified MRI protocol and to evaluate it for routine postoperative quality follow-up after ACL reconstruction.

Materials and methods

Various scanning protocols were tested in a series of 105 patients and evaluated for image sharpness, clarity of the structures, susceptibility to artefacts, applicability regarding precise analysis of graft and tunnel position, and time consumption. One simplified specific scan protocol was then defined and applied in a series of 60 consecutive patients after hamstring ACL replacement. The position of the femoral and tibial tunnels was measured in the sagittal, coronal and axial sections and classified according to Harner (femoral) and Stäubli (tibial). Impingement of the graft in the intercondylar roof was analysed according to Howell. The position of the bioabsorbable interference screws was assessed.

Results

Scan protocol: T2-weighted gradient-echo sequences (GRE) with TR 246 ms, TE 11 ms, flip angle 25°, 2 mm sections and a 256×256 matrix yielded the best image quality of tendon grafts and bone tunnels with tolerable time consumption (average scanning time per patient 1 min 40 s). Altogether 8–16 sections were obtained for every patient. Tunnel placement: 46/60 (77%) of the femoral tunnels were in zone 4, 13/60 (21%) at the border of zones 3 to 4, 1/60 (2%) in zone 3 in the sagittal plane (Harner). The femoral tunnels in the axial plane were at 10:30 o’clock in 32/60 (53%), at 11:00 o’clock at 24/60 (40%) and at 10:00 o’clock in 4/60 (4%) patients. The mean distance of the anterior border of the tibial tunnel from the anterior cortex was 39% (± 4.9%) related to the total sagittal diameter of the tibia. There was no graft impingement. The position of the interference screws was anterior to the grafts in all cases.

Conclusion

Simplified MRI sequences can be used for postoperative quality follow-up after ACL replacement and are an alternative to standard radiographs giving more specific and precise information regarding tunnel position and screw placement. Analyzing the bone tunnels in a series of 60 patients demonstrated that correct assessment of tunnel placement after arthroscopic ACL reconstruction is feasible using this simplified MRI technique.
Literature
1.
go back to reference Almekinders LC, Chiavetta JB, Clarke JP (1998) Radiographic evaluation of anterior cruciate ligament graft failure with special reference to tibial tunnel placement. Arthroscopy 14:206–211PubMed Almekinders LC, Chiavetta JB, Clarke JP (1998) Radiographic evaluation of anterior cruciate ligament graft failure with special reference to tibial tunnel placement. Arthroscopy 14:206–211PubMed
2.
go back to reference Arnoczky SP (1983) Anatomy of the anterior cruciate ligament. Clin Orthop 172:19–25PubMed Arnoczky SP (1983) Anatomy of the anterior cruciate ligament. Clin Orthop 172:19–25PubMed
3.
go back to reference Bernard M, Hertel P (1996) Intraoperative and postoperative insertion control of anterior cruciate ligament-plasty. A radiologic measuring method (quadrant method). Unfallchirurg 99:332–340PubMed Bernard M, Hertel P (1996) Intraoperative and postoperative insertion control of anterior cruciate ligament-plasty. A radiologic measuring method (quadrant method). Unfallchirurg 99:332–340PubMed
4.
go back to reference Harner CD, Marks PH, Fu FH, Irrgang JJ, Silby MB, Mengato R (1994) Anterior cruciate ligament reconstruction: endoscopic versus two-incision technique. Arthroscopy 10:502–512PubMed Harner CD, Marks PH, Fu FH, Irrgang JJ, Silby MB, Mengato R (1994) Anterior cruciate ligament reconstruction: endoscopic versus two-incision technique. Arthroscopy 10:502–512PubMed
5.
go back to reference Howell SM, Clark JA, Farley TE (1991) A rationale for predicting anterior cruciate graft impingement by the intercondylar roof. A magnetic resonance imaging study. Am J Sports Med 19:276–282PubMed Howell SM, Clark JA, Farley TE (1991) A rationale for predicting anterior cruciate graft impingement by the intercondylar roof. A magnetic resonance imaging study. Am J Sports Med 19:276–282PubMed
6.
go back to reference Howell SM, Gittins ME, Gottlieb JE, Traina SM, Zoellner TM (2001) The relationship between the angle of the tibial tunnel in the coronal plane and loss of flexion and anterior laxity after anterior cruciate ligament reconstruction. Am J Sports Med 29:567–574PubMed Howell SM, Gittins ME, Gottlieb JE, Traina SM, Zoellner TM (2001) The relationship between the angle of the tibial tunnel in the coronal plane and loss of flexion and anterior laxity after anterior cruciate ligament reconstruction. Am J Sports Med 29:567–574PubMed
7.
go back to reference Jacobsen K (1977) Osteoarthrosis following insufficiency of the cruciate ligaments in man. A clinical study. Acta Orthop Scand 48:520–526PubMed Jacobsen K (1977) Osteoarthrosis following insufficiency of the cruciate ligaments in man. A clinical study. Acta Orthop Scand 48:520–526PubMed
8.
go back to reference Kohn D, Busche T, Carls J (1998) Drill hole position in endoscopic anterior cruciate ligament reconstruction. Results of an advanced arthroscopy course. Knee Surg Sports Traumatol Arthrosc 6 [Suppl 1]:S13–15 Kohn D, Busche T, Carls J (1998) Drill hole position in endoscopic anterior cruciate ligament reconstruction. Results of an advanced arthroscopy course. Knee Surg Sports Traumatol Arthrosc 6 [Suppl 1]:S13–15
9.
go back to reference Lajtai G, Noszian I, Humer K, Unger F, Aitzetmuller G, Orthner E (1999) Serial magnetic resonance imaging evaluation of operative site after fixation of patellar tendon graft with bioabsorbable interference screws in anterior cruciate ligament reconstruction. Arthroscopy 15:709–718PubMed Lajtai G, Noszian I, Humer K, Unger F, Aitzetmuller G, Orthner E (1999) Serial magnetic resonance imaging evaluation of operative site after fixation of patellar tendon graft with bioabsorbable interference screws in anterior cruciate ligament reconstruction. Arthroscopy 15:709–718PubMed
10.
11.
go back to reference Markolf KL, Hame S, Hunter DM, Oakes DA, Zoric B, Gause P, Finerman GA (2002) Effects of femoral tunnel placement on knee laxity and forces in an anterior cruciate ligament graft. J Orthop Res 20:1016–1024CrossRefPubMed Markolf KL, Hame S, Hunter DM, Oakes DA, Zoric B, Gause P, Finerman GA (2002) Effects of femoral tunnel placement on knee laxity and forces in an anterior cruciate ligament graft. J Orthop Res 20:1016–1024CrossRefPubMed
12.
go back to reference McDaniel WJ Jr, Dameron TB Jr (1983) The untreated anterior cruciate ligament rupture. Clin Orthop 172:158–163PubMed McDaniel WJ Jr, Dameron TB Jr (1983) The untreated anterior cruciate ligament rupture. Clin Orthop 172:158–163PubMed
13.
go back to reference Petsche TS, Hutchinson MR (1999) Loss of extension after reconstruction of the anterior cruciate ligament. J Am Acad Orthop Surg 7:119–127PubMed Petsche TS, Hutchinson MR (1999) Loss of extension after reconstruction of the anterior cruciate ligament. J Am Acad Orthop Surg 7:119–127PubMed
14.
go back to reference Sommer C, Friederich NF, Muller W (2000) Improperly placed anterior cruciate ligament grafts: correlation between radiological parameters and clinical results. Knee Surg Sports Traumatol Arthrosc 8:207–213PubMed Sommer C, Friederich NF, Muller W (2000) Improperly placed anterior cruciate ligament grafts: correlation between radiological parameters and clinical results. Knee Surg Sports Traumatol Arthrosc 8:207–213PubMed
15.
go back to reference Stäubli HU, Rauschning W (1994) Tibial attachment area of the anterior cruciate ligament in the extended knee position. Anatomy and cryosections in vitro complemented by magnetic resonance arthrography in vivo. Knee Surg Sports Traumatol Arthrosc 2:138–146PubMed Stäubli HU, Rauschning W (1994) Tibial attachment area of the anterior cruciate ligament in the extended knee position. Anatomy and cryosections in vitro complemented by magnetic resonance arthrography in vivo. Knee Surg Sports Traumatol Arthrosc 2:138–146PubMed
Metadata
Title
Simplified MRI sequences for postoperative control of hamstring anterior cruciate ligament reconstruction
Authors
J. D. Agneskirchner
M. Galla
P. Landwehr
H. P. Lobenhoffer
Publication date
01-05-2004
Publisher
Springer-Verlag
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 4/2004
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-003-0616-7

Other articles of this Issue 4/2004

Archives of Orthopaedic and Trauma Surgery 4/2004 Go to the issue